Testing Lab. Shenzhen LCS Compliance Testing Laboratory Ltd. 地址 : 深圳市宝安区宝安大道通达路星源科技园 1 楼 Add: 1/F., Xingyuan Industrial Park, Tongda Road, Bao an Avenue, Bao an District, Shenzhen, Guangdong, China Tel: 0755-82591330 Http: www.lcs-cert.com Fax: 0755-82591332 webmaster@lcs-cert.com Report No.: LCS1412090524S TEST REPORT NAME OF SAMPLE TRADE MARK MODEL/TYPE CLIENT ADDRESS OF CLIENT INSPECTION CLASSIFICATION TEST ITEM 200 Watt Mightylite Mightylite 0022031-5, 0022031, 0022033, 0022035, 0022091, 0022093, 0022095 Global Tech China Limited 3 Flat A, Wai Yip Industrial Building, 171 Wai Yip Street, Kwun Tong, Kowloon, Hong Kong Commission Test IES Test
Testing Lab. Shenzhen LCS Compliance Testing Laboratory Ltd. 地址 : 深圳市宝安区宝安大道通达路星源科技园 1 楼 Add: 1/F., Xingyuan Industrial Park, Tongda Road, Bao an Avenue, Bao an District, Shenzhen, Guangdong, China Tel: 0755-82591330 Http: www.lcs-cert.com Fax: 0755-82591332 webmaster@lcs-cert.com Report No.: LCS1412090524S Photos of Sample Fig.1 Fig.2
Global Tech China Limited Shenzhen LCS Compliance Testing Laboratory Ltd. www.lcs-cert.com Email:webmaster@LCS-cert.com Tel:0755-82591330 Fax:0755-82591332 Address:1/F., Xingyuan Industrial Park, Tongda Road, Bao an Avenue, Bao an District, Shenzhen, Guangdong, China LumCAT: 0022031-5 Luminaire: 200 Watt Mightylite Report No: LCS1412090524S Voltage(V): 219.900 Test No: 1412220021 Current(A): 0.806 LampCAT: LED Power (W): 169.700 Lamp flux(lm) PF: 0.957 Number of Lamps: 1 Ballast type: - Length(mm): 311 Width(mm): 211 Phm Type: C Height(mm): 94 Photometric Results Lumens(lm): 9222.36 Lumens(lm)/Power(W): 54.35 Central intensity(cd): 4809.427 Maximum intensity(cd): 5453.882 Angle of maximum intensity: C=90.0 γ=25.0 Beam Angle(50%Imax): [C0/180]Left=47.0 Right=49.4 [C90/270]Left=17.2 Right=50.0 Field angle(10%imax): [C0/180]Left=69.5 Right=70.9 [C90/270]Left=33.4 Right=65.9 Beam angle of C90plane: 68.32 Maximum s/h: C0_180=1.22 C90_270=1.48 Up flux rate of LUM(%): 0.95% Down flux rate of LUM(%): 99.05% CIE Type : Direct lighting Output flux ratio in π solid angle : 89.726%
Zonal flux distribution table Page: 2 Total:15 γ( ) Average I(cd) Zonal F(lm) Sum F(lm) Eff Flux(%) Eff Sum(%) 0.0 4948.465.000.000.000%.000% 5.0 4948.576 118.316 118.316 1.283% 1.283% 10.0 4711.353 345.566 463.882 3.747% 5.030% 15.0 4392.420 540.030 1003.912 5.856% 10.886% 20.0 4103.272 700.164 1704.076 7.592% 18.478% 25.0 3778.694 826.673 2530.749 8.964% 27.441% 30.0 3406.936 909.348 3440.096 9.860% 37.302% 35.0 3018.373 946.172 4386.268 10.260% 47.561% 40.0 2609.032 938.890 5325.158 10.181% 57.742% 45.0 2191.795 888.912 6214.070 9.639% 67.381% 50.0 1802.124 807.030 7021.100 8.751% 76.131% 55.0 1415.078 699.527 7720.627 7.585% 83.716% 60.0 982.574 554.210 8274.838 6.009% 89.726% 65.0 591.915 382.761 8657.600 4.150% 93.876% 70.0 331.859 233.906 8891.505 2.536% 96.413% 75.0 161.740 129.019 9020.523 1.399% 97.811% 80.0 77.822 64.100 9084.624.695% 98.507% 85.0 41.997 32.558 9117.182.353% 98.860% 90.0 21.559 17.402 9134.584.189% 99.048% 95.0 9.818 8.591 9143.175.093% 99.141% 100.0 3.866 3.718 9146.894.040% 99.182% 105.0 4.558 2.254 9149.147.024% 99.206% 110.0 6.293 2.836 9151.983.031% 99.237% 115.0 8.336 3.704 9155.688.040% 99.277% 120.0 10.554 4.592 9160.279.050% 99.327% 125.0 12.948 5.433 9165.712.059% 99.386% 130.0 15.343 6.151 9171.863.067% 99.452% 135.0 17.726 6.682 9178.545.072% 99.525% 140.0 19.944 6.975 9185.520.076% 99.601% 145.0 22.031 7.003 9192.522.076% 99.677% 150.0 23.997 6.778 9199.301.073% 99.750% 155.0 25.853 6.309 9205.609.068% 99.818% 160.0 27.555 5.602 9211.211.061% 99.879% 165.0 29.005 4.661 9215.872.051% 99.930% 170.0 30.301 3.518 9290.038% 99.968% 175.0 31.399 2.207 9221.597.024% 99.992% 180.0 32.113.759 9222.355.008% 100.000%
Zonal flux distribution table Page: 3 Total:15 ZONAL LUMEN SUMMARY Zone Lumens %Fixt 0-30 3440.10 37.30% 0-40 5325.16 57.74% 0-60 8274.84 89.73% 0-90 9134.58 99.05% 0-120 9160.28 99.33% 0-180 9222.36 100.00% 60-90 1413.96 15.33% 90-120 43.10 0.47% 90-130 54.68 0.59% 90-150 82.12 0.89% 90-180 104.42 1.13% 0-52.55 7377.88 80.00% ZONAL LUMEN SUMMARY 0-10 463.88 10-20 1240.19 20-30 1736.02 30-40 1885.06 40-50 1695.94 50-60 1253.74 60-70 616.67 70-80 193.12 80-90 49.96 90-100 12.31 100-110 5.09 110-120 8.30 120-130 11.58 130-140 13.66 140-150 13.78 150-160 11.91 160-170 8.18 170-180 2.21
Light Distribution Curve [Unit:cd] Page: 4 Total:15 ±180-150 150-120 120-90 90 1090.78-60 2181.55 3272.33 60-30 4363.11 5453.88 0 30 5453.88 4363.11 3272.33 2181.55 1090.78 0.00-180 -135-90 -45 0 45 90 135 180 C90(Max): C0/C180: C90/C270: Field angle(10%imax):c0/180left:69.5 Right:70.9 :C90/270Left:33.4 Right:65.9 Beam Angle(50%Imax):C0/180Left:47.0 Right:49.4 :C90/270Left:17.2 Right:50.0
Lux distance Curve Page: 5 Total:15 2.0m 4.0m 6.0m 8.0m 10.0m 12.0m 14.0m 16.0m 18.0m 20.0m 1202.4lux 300.6lux 133.6lux 75.1lux 48.1lux 33.4lux 24.5lux lux 14.8lux 12.0lux 3.1m 6.1m 9.2m 12.3m 15.4m 18.4m 21.5m 24.6m 27.6m 30.7m Beam angle of C90plane68.32
ISO-Intensity(V-H) Page: 6 Total:15 90 [Unit:cd] Imax:5453.88cd 75 60 45 30 15 0-15 -30-45 -60-75 -90-90 -75-60 -45-30 -15 0 15 30 45 60 75 90 (10%Imax) 545.388 (20%Imax) 1090.78 (30%Imax) 1636.16 (40%Imax) 2181.55 (50%Imax) 2726.94 (60%Imax) 3272.33 (70%Imax) 3817.72 (80%Imax) 4363.11 (90%Imax) 4908.49
ISO candela diagram on circular web 180 Page: 7 Total:15 150 150 120 120 270 300 330 0 30 60 90 90 90 60 60 30 30 House 0 [Unit:cd] Imax:5453.88 (10%Imax) 545.388 (20%Imax) 1090.78 (30%Imax) 1636.16 (40%Imax) 2181.55 (50%Imax) 2726.94 (60%Imax) 3272.33 (70%Imax) 3817.72 (80%Imax) 4363.11 (90%Imax) 4908.49 Road
ISO illuminance diagram Page: 8 Total:15 1.7d/h [Unit:lx] H=4.0m Emax:317.89 C 180 1.3 1.0 0.7 0.3 0.0 C 270 C 90 0.3 0.7 1.0 1.3 1.7d/h 1.7d/h C 0 1.3 1.0 0.7 0.3 0.0 0.3 0.7 1.0 1.3 1.7d/h (10%Emax) 31.78863 (20%Emax) 63.5775 (30%Emax) 95.36625 (40%Emax) 127.1544 (50%Emax) 158.9431 (60%Emax) 190.7319 (70%Emax) 222.5206 (80%Emax) 254.3094 Equipment: (90%Emax) GMS-1800B 286.0981 Date: 2014-12-22 Operator: Marine
Space ISO Lux diagram Page: 9 Total:15 1.0m 1.5m 2.5m Imax:5453.88 [Unit:lx] 481.367 962.735 1444.1 1925.47 2406.84 2888.2 3369.57 3850.94 4332.31 3.5m 4.5m 5.5m 0.0m 0.5m 1.0m 1.5m 2.0m 2.5m 3.0m 3.5m 4.0m 4.5m
Luminance Limitting Curve(no luminous side) Page: 10 Total:15 Luminance Table γ 45 50 55 60 65 70 75 80 85 C0 42448 37007 30715 24266 17141 10743 5916 3030 1437 C45 0 0 0 0 0 0 0 0 0 C90 56670 47464 37745 22576 13119 7189 4974 3899 3559 Glare Table Glare Quality Service Values Illuminance(lx) 1.15 A 2000 1000 500 <=300 1.5 B 2000 1000 500 <=300 1.85 C 2000 1000 500 <=300 2.2 D 2000 1000 500 <=300 2.55 E 2000 1000 500 <=300 a b c d e f g h Luminance Limitting Curve γ( ) 85 75 65 a b c d e f g h 8 (a/hs) 6 4 3 2 55 45 6 7 8 9 1000 2 3 4 5 6 7 8 9 10000 2 3 4 L(cd/m²) C0 C45 C90
UGR Glare Page: 11 Total:15 Illuminatin assessment acconding UGR Rf of Ceiling 70 70 50 50 30 70 70 50 50 30 Rf of Wall 50 30 50 30 30 50 30 50 30 30 Rf of Floor 20 20 20 20 20 20 20 20 20 20 Room dimensions Viewed crosswise Viewed endwise X Y 2H 2H 3H 4H 6H 8H 12H 18.4 18.9 18.9 18.9 19.6 20.0 19.2 19.2 19.1 19.9 20.2 20.0 20.1 20.1 20.1 20.5 20.4 20.4 20.4 20.2 17.9 17.9 17.8 17.9 17.9 17.7 19.1 19.0 18.4 18.2 18.3 18.2 18.2 18.3 18.1 19.0 19.1 19.1 19.6 19.6 19.2 4H 2H 3H 4H 6H 8H 12H 18.6 19.2 19.5 19.5 19.9 20.1 20.1 19.0 19.9 20.3 20.5 20.5 20.2 20.2 20.2 20.7 20.9 20.9 20.7 20.7 18.1 18.2 18.3 18.4 18.2 18.3 19.0 18.9 19.0 19.0 18.6 18.6 18.5 19.1 19.1 19.6 19.6 8H 4H 6H 8H 12H 19.6 19.9 19.9 19.9 20.1 20.2 20.3 20.3 20.7 20.8 20.8 20.8 18.3 18.3 18.4 18.4 18.6 18.9 18.9 19.1 19.2 19.2 19.6 12H 4H 6H 8H 19.9 19.9 20.1 20.2 20.3 20.7 20.8 20.8 18.3 18.3 18.4 18.6 18.9 18.9 19.1 19.2 19.2 19.6 Variation with the observer position at spacings: S = 1.0H 0.7/-0.7 0.6/-0.9 S = 1.5H 1.4/-2.3 1.2/-3.4 S = 2.0H 2.6/-3.6 3.5/-5.5 Standard tables: BK2 BK1 Uncorrected UGR According 1000lm 1.8 0.4
Budgetary Estimate Table Page: 12 Total:15 Budgetary Estimate Tab 40 Lamp Flux Maint Co 0.8/0.8 Ave Illu 100.0 lx 30 Plane H 0.0 m Place C W F Refl1 0.7 0.5 0.2 20 Refl2 0.5 0.3 0.2 [N] 10 9 8 7 6 5 4 3 2 1 6m 1 2 3 4 5 6 7 8 9 10 20 S[m2] 40 60 80 100 200 400 600 800 2m
Utilization factor table for indoor luminaire Page: 13 Total:15 RHOCC 80 70 50 30 10 0 RHOW 50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0 RCR COEFFCIENTS OF UTILIZATION RHOFC=20 CU 0 1.19 1.19 1.19 1.16 1.16 1.16 1.11 1.11 1.11 1.06 1.06 1.06 1.01 1.01 1.01 0.99 1 1.07 1.03 1.00 1.04 1.01 0.99 1.00 0.98 0.95 0.96 0.94 0.92 0.93 0.91 0.89 0.87 2 0.95 0.90 0.85 0.94 0.88 0.84 0.90 0.86 0.82 0.87 0.83 0.80 0.84 0.81 0.78 0.76 3 0.86 0.79 0.73 0.84 0.77 0.72 0.81 0.75 0.71 0.78 0.74 0.70 0.76 0.72 0.68 0.66 4 0.77 0.69 0.63 0.76 0.69 0.63 0.73 0.67 0.62 0.71 0.65 0.61 0.69 0.64 0.60 0.58 5 0.70 0.62 0.56 0.69 0.61 0.56 0.66 0.60 0.55 0.64 0.59 0.54 0.63 0.58 0.54 0.52 6 0.63 0.55 0.50 0.62 0.55 0.49 0.61 0.54 0.49 0.59 0.53 0.48 0.57 0.52 0.48 0.46 7 0.58 0.50 0.44 0.57 0.50 0.44 0.56 0.49 0.44 0.54 0.48 0.44 0.53 0.47 0.43 0.41 8 0.53 0.46 0.40 0.53 0.45 0.40 0.51 0.45 0.40 0.50 0.44 0.40 0.49 0.43 0.39 0.37 9 0.49 0.42 0.37 0.49 0.41 0.36 0.47 0.41 0.36 0.46 0.40 0.36 0.45 0.40 0.36 0.34 10 0.46 0.38 0.33 0.45 0.38 0.33 0.44 0.38 0.33 0.43 0.37 0.33 0.42 0.37 0.33 0.31 RCR COEFFCIENTS OF UTILIZATION RHOFC=20 WLC 1 0.25 0.14 0.04 0.24 0.14 0.04 0.23 0.13 0.04 0.22 0.12 0.04 0.20 0.12 0.04 2 0.24 0.13 0.04 0.24 0.13 0.04 0.22 0.12 0.04 0.21 0.12 0.04 0.20 0.11 0.04 3 0.23 0.12 0.04 0.22 0.12 0.04 0.21 0.12 0.04 0.20 0.11 0.03 0.19 0.11 0.03 4 0.22 0.11 0.03 0.21 0.11 0.03 0.20 0.11 0.03 0.19 0.10 0.03 0.19 0.10 0.03 5 0.20 0.10 0.03 0.20 0.10 0.03 0.19 0.10 0.03 0.18 0.10 0.03 0.18 0.09 0.03 6 0.19 0.10 0.03 0.19 0.09 0.03 0.18 0.09 0.03 0.17 0.09 0.03 0.17 0.09 0.03 7 0.18 0.09 0.03 0.18 0.09 0.02 0.17 0.09 0.02 0.16 0.08 0.02 0.16 0.08 0.02 8 0.17 0.08 0.02 0.17 0.08 0.02 0.16 0.08 0.02 0.15 0.08 0.02 0.15 0.08 0.02 9 0.16 0.08 0.02 0.16 0.08 0.02 0.15 0.07 0.02 0.15 0.07 0.02 0.14 0.07 0.02 10 0.15 0.07 0.02 0.15 0.07 0.02 0.14 0.07 0.02 0.14 0.07 0.02 0.14 0.07 0.02 RCR COEFFCIENTS OF UTILIZATION RHOFC=20 CCLU 0 0.20 0.20 0.20 0.17 0.17 0.17 0.12 0.12 0.12 0.07 0.07 0.07 0.02 0.02 0.02 1 0.16 0.15 0.14 0.14 0.13 0.12 0.10 0.09 0.09 0.06 0.06 0.05 0.02 0.02 0.02 2 0.13 0.12 0.10 0.12 0.10 0.09 0.09 0.08 0.07 0.06 0.05 0.04 0.02 0.02 0.01 3 0.11 0.09 0.08 0.10 0.08 0.07 0.08 0.06 0.05 0.05 0.04 0.03 0.02 0.01 0.01 4 0.09 0.08 0.06 0.09 0.07 0.05 0.07 0.06 0.04 0.05 0.04 0.03 0.02 0.01 0.01 5 0.08 0.06 0.05 0.08 0.06 0.04 0.07 0.05 0.03 0.05 0.03 0.02 0.02 0.01 0.01 6 0.07 0.05 0.04 0.07 0.05 0.04 0.06 0.04 0.03 0.04 0.03 0.02 0.02 0.01 0.01 7 0.06 0.05 0.03 0.07 0.05 0.03 0.06 0.04 0.02 0.04 0.03 0.02 0.02 0.01 0.01 8 0.06 0.04 0.03 0.06 0.04 0.03 0.06 0.04 0.02 0.04 0.03 0.01 0.02 0.01 0.00 9 0.05 0.04 0.02 0.06 0.04 0.02 0.05 0.03 0.02 0.04 0.02 0.01 0.02 0.01 0.00 10 0.05 0.03 0.02 0.05 0.03 0.02 0.05 0.03 0.02 0.04 0.02 0.01 0.01 0.01 0.00
Intensity data(cd) Page: 14 Total:15 C/γ( ) 0.0 5.0 10.0 15.0 20.0 25.0 30.0 35.0 40.0 0.0 4809.43 4889.82 4863.46 4717.17 4522.12 4280.95 3979.15 3624.63 3243.76 30.0 5120.45 5293.10 5244.34 5055.88 4842.38 4731.67 4543.21 4391.65 4159.70 60.0 5051.92 5220.61 5115.18 5088.82 5240.38 5307.59 5293.10 5098.05 4564.30 90.0 4953.08 5117.82 5084.87 5260.15 5410.39 5453.88 5381.40 4887.18 4143.89 120.0 4905.63 5030.83 4962.30 4946.49 5038.74 5075.64 5080.92 4934.63 4362.66 150.0 4850.28 4997.89 4903.00 4700.04 4599.88 4418.01 4226.91 4056.90 3826.27 180.0 4809.43 4895.09 4829.20 4706.63 4483.90 4170.24 3880.30 3488.89 3102.74 210.0 5120.45 5033.47 4738.26 4195.28 3620.68 3044.75 2378.95 1868.00 1354.02 240.0 5051.92 4763.30 4154.43 3366.32 2678.38 2012.84 1284.03 690.98 342.52 270.0 4953.08 4624.92 3831.54 3043.44 2339.94 1636.97 806.03 46 324.47 300.0 4905.63 4701.36 4172.88 3395.32 2765.36 2080.05 1447.45 734.47 370.99 330.0 4850.28 4814.70 4636.78 4233.50 3697.12 3131.74 2581.77 2025.75 1513.09 360.0 4809.43 4889.82 4863.46 4717.17 4522.12 4280.95 3979.15 3624.63 3243.76 C/γ( ) 45.0 50.0 55.0 60.0 65.0 70.0 75.0 80.0 85.0 0.0 2847.07 2389.76 1891.59 1410.55 929.52 536.26 267.53 121.77 50.08 30.0 3843.40 3458.58 2889.24 2119.59 1427.69 850.44 377.05 170.14 86.19 60.0 3769.60 301 2305.28 1485.28 701.52 341.34 180.42 113.47 79.07 90.0 3424.31 2723.19 2033.92 1128.52 599.65 295.34 179.76 120.59 90.67 120.0 3631.22 2906.37 2219.22 1476.71 694.54 339.23 170.54 105.43 71.30 150.0 3471.75 3126.46 2645.43 2006.25 1338.07 797.73 385.09 164.21 79.21 180.0 2630.67 2182.32 1692.58 1224.33 787.45 456.52 225.89 102.66 33.61 210.0 778.49 406.44 258.18 193.34 145.10 93.70 46.52 14.23 4.48 240.0 288.62 280.58 253.96 180.16 111.23 57.46 21.35 1.98 1.45 270.0 303.51 289.02 238.94 168.30 103.85 56.27 14.23 0.92 0.92 300.0 276.76 267.40 247.90 191.10 116.50 60.76 23.59 2.37 1.45 330.0 1036.14 575.66 304.70 206.78 147.87 97.26 48.89 16.08 5.54 360.0 2847.07 2389.76 1891.59 1410.55 929.52 536.26 267.53 121.77 50.08 C/γ( ) 90.0 95.0 100.0 105.0 110.0 115.0 120.0 125.0 130.0 0.0 13.57 2.50 3.56 5.14 7.12 9.23 11.60 13.97 16.34 30.0 38.61 12.52 1.32 1.85 2.77 3.95 5.40 7.51 9.49 60.0 49.68 21.75 2.77 1.05 1.32 1.71 2.37 3.43 4.88 90.0 62.34 30.31 2.24 0.92 1.19 1.45 1.85 2.50 3.69 120.0 41.65 17.40 2.24 1.05 1.19 1.71 2.50 3.56 5.27 150.0 30.31 9.09 5.01 2.50 3.16 4.48 6.06 8.17 10.28 180.0 11.20 8.83 4.61 5.80 7.78 10.02 12.39 14.89 17.40 210.0 3.95 4.22 6.33 8.96 11.86 15.02 18.19 21.09 24.12 240.0 1.71 2.64 4.48 6.98 10.15 13.71 17.53 21.09 24.12 270.0 1.45 2.24 3.82 6.06 8.96 12.52 16.47 20.56 24.25 300.0 1.71 2.64 4.35 6.59 9.62 12.92 16.34 7 22.80 330.0 2.50 3.69 5.67 7.78 10.41 13.31 15.95 5 21.48 360.0 13.57 2.50 3.56 5.14 7.12 9.23 11.60 13.97 16.34 C/γ( ) 135.0 140.0 145.0 150.0 155.0 160.0 165.0 170.0 175.0 0.0 1 20.95 23.06 24.78 26.23 27.81 29.13 30.31 31.23 30.0 11.86 14.10 16.34 18.32 20.16 22.27 24.51 27.15 30.05 60.0 6.98 9.36 12.26 15.02 17.79 20.30 22.80 25.70 29.13 90.0 5.27 7.38 10.15 13.05 16.21 19.24 21.48 24.51 27.81 120.0 7.25 9.88 12.39 15.16 18.06 20.56 23.06 25.57 28.73 150.0 12.52 14.76 17.00 18.98 20.95 22.93 25.04 27.28 29.39 180.0 19.64 21.61 23.59 24.91 26.36 27.81 29.26 30.58 31.10 210.0 26.62 28.73 30.31 31.63 32.82 33.74 34.40 34.53 33.87 240.0 27.15 29.13 30.71 32.42 33.61 34.66 35.32 35.19 34.40 270.0 27.28 29.78 31.37 32.95 34.40 35.72 36.24 35.85 34.79 300.0 25.44 27.41 29.26 31.23 32.68 33.74 34.40 34.13 33.61 330.0 23.99 26.23 27.94 29.52 30.97 31.89 32.42 32.82 32.68 360.0 1 20.95 23.06 24.78 26.23 27.81 29.13 30.31 31.23
Intensity data(cd) C/γ( ) 180.0 0.0 31.89 30.0 32.82 60.0 32.42 90.0 32.03 120.0 31.76 150.0 31.76 180.0 31.89 210.0 32.82 240.0 32.42 270.0 32.03 300.0 31.76 330.0 31.76 360.0 31.89 Page: 15 Total:15