+86-760-88758975 Page 1 of 19 Pages Report No.: 10 Test Time: 2017/11/25 15:10 Luminaire Property Luminaire Manufacturer: Luminaire Description: SMD-WANT-SS-100 Voltage: 220V Current: 0.938 A Power: 102.6W Power Factor: 0.995 Photometric Results CIE Class: Direct Total Rated Lamp Lumens: 9042.5 lm Measurement Flux: 9042.5 lm Efficiency: 100% Downward Ratio: 99% Upward Ratio: 1% Horizontal Diffuse Angle(50%): H106 Vertical Diffuse Angle(50%): V101.8 Luminaire Efficacy Rating (LER): 88.18 Central Intensity: 3775.8 cd Max. Intensity: 3786.33 cd Pos of Max. Intensity: H180 V4 S/MH(C0/C180): 1.27 S/MH(C90/C270): 1.23 Picture Of Luminaire Luminous Intensity Distribution Curve 160 170 150 140 130 120 110 100 180 170 160 150 140 130 120 110 100 90 90 946 80 80 70 1893 70 60 2839 60 50 3786 50 40 40 30 4732 30 20 10 0 10 20 Unit: cd Average Diffuse Angle(50%): 103.9 C0-C180 C90-C270 G4
+86-760-88758975 Page 2 of 19 Pages Luminous Intensity Distribution Curve 170 160 150 140 130 120 110 100 180 170 160 150 140 130 120 110 100 90 90 80 70 60 946 1893 2839 80 70 60 50 40 30 20 10 3786 4732 0 10 20 30 50 40 4732 3786 2839 1893 946 0-180 -120-60 0 60 120 180 C0-C180 C90-C270 Unit: cd
+86-760-88758975 Page 3 of 19 Pages Luminous Intensity Distribution Curve(cd/klm) 150 160 170 180 170 160 150 140 140 130 130 120 120 110 110 100 100 90 90 80 104 80 70 209 70 60 314 60 50 40 418 40 50 30 cd/klm C0-C180 C90-C270 20 10 523 0 10 20 30 η=100%
RC RW RCR 0 1 2 3 4 5 6 7 8 9 10 杭州创惠仪器有限公司 +86-760-88758975 Page 4 of 19 Pages Coefficients Of Utilization - Zonal Cavity Method 0.8 0.8 0.8 0.8 0.7 0.7 0.7 0.7 0.5 0.5 0.5 0.3 0.3 0.3 0.1 0.1 0.1 0 0.7 0.5 0.3 0.1 0.7 0.5 0.3 0.1 0.5 0.3 0.1 0.5 0.3 0.1 0.5 0.3 0.1 0 Spacing Criteria (0-180): 1.27 Spacing Criteria (90-270): 1.23 Spacing Criteria (Diagonal): 1.35 N 30 25 20 15 RF = 119 119 119 119 116 116 116 116 111 111 111 106 106 106 101 101 101 99 111 107 103 100 108 104 101 98 100 97 95 96 94 92 92 91 89 87 102 95 89 84 99 93 87 83 89 85 81 86 82 79 83 80 77 75 94 84 77 71 91 83 76 71 80 74 69 77 72 68 74 70 67 65 86 75 67 61 84 74 66 61 71 65 60 69 63 59 67 62 58 56 79 68 59 53 77 66 59 53 64 57 52 62 56 52 60 55 51 49 73 61 53 47 72 60 52 46 58 51 46 56 50 45 55 49 45 43 68 55 47 41 66 55 47 41 53 46 41 52 45 40 50 44 40 38 64 51 43 37 62 50 42 37 49 42 37 47 41 36 46 40 36 34 59 47 39 33 58 46 38 33 45 38 33 44 37 33 43 37 33 31 56 43 35 30 54 42 35 30 41 35 30 40 34 30 39 34 30 28 Curves of Luminaires vs Lighting Area 10 H=12 H=2 8 7 6 Luminous Flux 5000 lm 5 Maintain Factor 0.70 4 Suspend Length 0.00m Work Height 0.80m 3 Average Lux 100 lx Reflectivity(%) Line Type Ceil Wall Floor 70 50 30 2 10 2 2 3 4 5 6 7 8 910 3 2 3 4 5 6 7 8 910 4 A(sq.m) H=10 H=7 H=5 H=3
+86-760-88758975 Page 5 of 19 Pages Isocandela (rectangle) 80 60 Vertical(Deg) 40 20 0-20 379 189 757 568 947 1893 2840-40 -60-80 -80-60 -40-20 0 20 40 60 80 Horizontal(Deg) Imax (100%): 3786 cd ( 5%): 189 cd ( 10%): 379 cd ( 15%): 568 cd ( 20%): 757 cd ( 25%): 947 cd ( 50%): 1893 cd ( 75%): 2840 cd (100%): 3786 cd
+86-760-88758975 Page 6 of 19 Pages IsoLux Plot 5 19 4 3 23 2 Horizontal(m) 1 0 1 26 30 34 2 3 4 5 5 4 3 2 1 0 1 2 3 4 5 Vertical(m) Mounting Height: 10.0m Max Lux(100%): 37.8 lx ( 50%): 18.9 lx ( 60%): 22.7 lx ( 70%): 26.4 lx ( 80%): 3 lx ( 90%): 34.0 lx (100%): 37.8 lx
+86-760-88758975 Page 7 of 19 Pages Lum Limit Curve Dazzle Quality Illuminance (lx) 1.15 A 2000 1000 500 <=300 1.50 B 2000 1000 500 <=300 1.85 C 2000 1000 500 <=300 2.20 D 2000 1000 500 <=300 2.55 E 2000 1000 500 <=300 a b c d e f g h Gamma 85 75 65 a b c d e f g h 8 6 4 a/hs 3 2 55 45 6 7 8 9 1000 2 3 4 5 6 7 8 9 10000 2 3 4 C90 C270 L(cd/sq.m) Gamma 85 75 65 55 a b c d e f g h 8 6 4 a/hs 3 2 45 6 7 8 9 1000 2 3 4 5 6 7 8 9 10000 2 3 4 C0 C180 L(cd/sq.m) L(cd/sq.m) G45 G50 G55 G60 G65 G70 G75 G80 G85 C0 2400 2022 1598 1156 734 365 76 13 9 C90 2315 1913 1439 1032 583 216 28 17 10 C180 2538 2240 1767 1335 926 521 182 18 11 C270 2282 1959 1423 1020 580 183 32 19 11
+86-760-88758975 Page 8 of 19 Pages Illuminance at a Distance Dist(m) Enadir(lx) Dh/Dv_B(m) S_B(sq.m) Eav_B(lx) 1.0 3775.80 2.65/2.46 5.6 698.74 2.0 943.95 5.30/4.92 22.6 174.69 3.0 419.53 7.95/7.38 50.8 77.64 4.0 235.99 10.60/9.84 90.3 43.67 5.0 151.03 13.25/12.30 141.2 27.95 6.0 104.88 15.90/14.76 203.3 19.41 7.0 77.06 18.55/17.22 276.7 14.26 8.0 59.00 21.20/19.69 361.4 10.92 10.0 37.76 26.50/24.61 564.6 6.99 Dh 12.0 26.22 31.80/29.53 813.0 4.85 Dv Beam Angle(B): H105.9 V101.8 Field Angle(F): H141.7 V135.0
+86-760-88758975 Page 9 of 19 Pages Vertical IsoLux Plot 1 2265 1888 2 3 4 Vertical Height(m) 5 6 7 8 9 10 11 0 1 2 3 4 5 6 7 8 9 10 Horizontal distance(m) Lowest(m): 1.0m Highest(m): 11.0m Max Lux: 3775.8 lx ( 50%):1887.9 lx ( 60%):2265.5 lx ( 70%):2643.1 lx ( 80%):3020.6 lx ( 90%):3398.2 lx (100%):3775.8 lx
+86-760-88758975 Page 10 of 19 Pages The Average Illuminance Effective Figure Flux Out: 7057.72lm 1.0m 1279.95/ 3775.80lx 2.65m / 5.51sq.m 2.0m 319.99/ 943.95lx 5.30m / 22.06sq.m 3.0m 142.22/ 419.53lx 7.95m / 49.63sq.m 4.0m 80.00/ 235.99lx 10.60m / 88.23sq.m 5.0m 51.20/ 151.03lx 13.25m / 137.85sq.m 6.0m 35.55/ 104.88lx 15.90m / 198.51sq.m 7.0m 26.12/ 77.06lx 18.55m / 270.19sq.m 8.0m 20.00/ 59.00lx 21.20m / 352.90sq.m 10.0m 12.80/ 37.76lx 26.50m / 551.41sq.m 12.0m 8.89/ 26.22lx 31.80m / 794.03sq.m Height Avg./Nadir. E Beam Angle:105.9 Diameter / Area
+86-760-88758975 Page 11 of 19 Pages UGR Table Reflectance: Ceiling (cavity) 0.7 0.7 0.5 0.5 0.3 0.7 0.7 0.5 0.5 0.3 Wall 0.5 0.3 0.5 0.3 0.3 0.5 0.3 0.5 0.3 0.3 Reference plane Room dimensions X=2H Y=2H 3H 4H 6H 8H 12H X=4H Y=2H 3H 4H 6H 8H 12H X=8H Y=4H 6H 8H 12H X=12H Y=4H 6H 8H Viewed crosswise Viewed endwise Variations with the observer position at spacings: S=1.0H -1.$/-1.$ -1.$/-1.$ S=1.5H -1.$/-1.$ -1.$/-1.$ S=2.0H -1.$/-1.$ -1.$/-1.$ Calculate in accordance with CIE Pub.117. The table is revised with 9043lm (8log(F/F0) = 7.7).
+86-760-88758975 Page 12 of 19 Pages Utilisation Factor Table(Floor cavity) Utilisation Factors UF(F) SHR NOM = 1.25 Room Reflectance Room Index(RI) Ceiling Wall Floor 0.75 1.00 1.25 1.50 2.00 2.50 3.00 4.00 5.00 0.70 0.50 0 0.62 0.73 0.80 0.85 0.92 0.97 1.00 1.04 1.06 0.30 0.55 0.66 0.74 0.79 0.87 0.92 0.96 1.00 1.03 0 0.50 0.61 0.69 0.75 0.83 0.88 0.92 0.97 1.01 0.50 0.50 0 0.60 0.71 0.78 0.83 0.89 0.93 0.96 0.99 1.02 0.30 0.54 0.65 0.72 0.78 0.85 0.89 0.93 0.97 0.99 0 0.49 0.60 0.68 0.73 0.81 0.86 0.90 0.94 0.97 0.30 0.50 0 0.59 0.69 0.76 0.80 0.86 0.90 0.92 0.96 0.98 0.30 0.53 0.64 0.71 0.76 0.83 0.87 0.90 0.94 0.96 0 0.49 0.60 0.67 0.72 0.79 0.84 0.87 0.92 0.94 0.00 0.00 0.00 0.47 0.57 0.64 0.69 0.76 0.80 0.83 0.87 0.89 Rating:105W Photometrically tested without ceiling board. Multiply UF values by service correction factors Calculate in accordance with CIBSE Technical Memorandum NO.5 1980
+86-760-88758975 Page 13 of 19 Pages Utilisation Factor Table(Wall) Utilisation Factors UF(W) SHR NOM = 1.25 Room Reflectance Room Index(RI) Ceiling Wall Floor 0.75 1.00 1.25 1.50 2.00 2.50 3.00 4.00 5.00 0.70 0.50 0 0.91 0.73 0.61 0.52 0.40 0.33 8 1 0.17 0.30 0.76 0.62 0.53 0.46 0.37 0.30 6 0 0.17 0 0.65 0.54 0.47 0.41 0.33 8 4 0.19 0.16 0.50 0.50 0 0.88 0.70 0.58 0.49 0.38 0.35 6 0 0.16 0.30 0.74 0.61 0.51 0.44 0.35 9 5 0.19 0.16 0 0.64 0.53 0.46 0.40 0.32 7 3 0.18 0.15 0.30 0.50 0 0.85 0.67 0.55 0.47 0.36 0.30 5 0.19 0.15 0.30 0.72 0.59 0.49 0.43 0.34 8 3 0.18 0.15 0 0.63 0.52 0.45 0.39 0.31 6 2 0.17 0.14 0.00 0.00 0.00 0.53 0.42 0.35 0.30 3 0.19 0.16 0.12 0.10 Rating:105W Photometrically tested without ceiling board. Multiply UF values by service correction factors Calculate in accordance with CIBSE Technical Memorandum NO.5 1980
+86-760-88758975 Page 14 of 19 Pages Utilisation Factor Table(Ceiling cavity) Utilisation Factors UF(C) SHR NOM = 1.25 Room Reflectance Room Index(RI) Ceiling Wall Floor 0.75 1.00 1.25 1.50 2.00 2.50 3.00 4.00 5.00 0.70 0.50 0 0.17 0.18 0.18 0.19 0 1 1 2 2 0.30 0.10 0.12 0.13 0.14 0.16 0.17 0.18 0.19 0 0 0.06 0.08 0.09 0.11 0.13 0.14 0.15 0.17 0.18 0.50 0.50 0 0.16 0.17 0.18 0.18 0.19 0 0 1 1 0.30 0.10 0.12 0.13 0.14 0.15 0.17 0.17 0.19 0.19 0 0.06 0.07 0.09 0.10 0.12 0.14 0.15 0.17 0.18 0.30 0.50 0 0.15 0.16 0.17 0.18 0.19 0.19 0.19 0 0 0.30 0.10 0.11 0.13 0.14 0.15 0.16 0.17 0.18 0.19 0 0.06 0.07 0.09 0.10 0.12 0.14 0.15 0.16 0.17 0.00 0.00 0.00 0.01 0.01 0.01 0.01 0.01 0.01 0.01 0.01 0.01 Rating:105W Photometrically tested without ceiling board. Multiply UF values by service correction factors Calculate in accordance with CIBSE Technical Memorandum NO.5 1980
+86-760-88758975 Page 15 of 19 Pages Zonal Lumen Gamma Imean Zonal Flux Sum Zonal Flux Rel Zonal FluxSum Rel Zonal Flux [ ] [cd] [lm] [lm] [%] [%] 0.0-1.0 3690.1 3.5 3.5 0.04 0.04 1.0-2.0 3688.2 10.6 14.1 0.12 0.16 2.0-3.0 3685.8 17.6 31.7 0.19 0.35 3.0-4.0 3683.2 24.7 56.4 7 0.62 4.0-5.0 3678.9 31.7 88.1 0.35 0.97 5.0-6.0 3673.5 38.6 126.7 0.43 1.40 6.0-7.0 3667.6 45.5 172.2 0.50 1.90 7.0-8.0 3660.7 52.4 224.6 0.58 2.48 8.0-9.0 3652.4 59.2 283.8 0.65 3.14 9.0-10.0 3643.3 65.9 349.7 0.73 3.87 10.0-11.0 3633.8 72.6 422.4 0.80 4.67 11.0-12.0 3623.2 79.2 501.6 0.88 5.55 12.0-13.0 3610.4 85.7 587.3 0.95 6.49 13.0-14.0 3597.1 92.1 679.3 1.02 7.51 14.0-15.0 3583.7 98.4 777.7 1.09 8.60 15.0-16.0 3568.0 104.6 882.3 1.16 9.76 16.0-17.0 3550.1 110.6 992.9 1.22 10.98 17.0-18.0 3530.8 116.4 1109.3 1.29 12.27 18.0-19.0 3509.4 122.1 1231.4 1.35 13.62 19.0-20.0 3485.0 127.6 1359.0 1.41 15.03 20.0-21.0 3460.3 132.9 1491.9 1.47 16.50 21.0-22.0 3435.2 138.1 1629.9 1.53 18.03 22.0-23.0 3407.3 143.0 1772.9 1.58 19.61 23.0-24.0 3377.1 147.7 1920.6 1.63 21.24 24.0-25.0 3346.5 152.2 2072.8 1.68 22.92 25.0-26.0 3314.3 156.5 2229.3 1.73 24.65 26.0-27.0 3277.0 160.3 2389.6 1.77 26.43 27.0-28.0 3238.2 164.0 2553.6 1.81 28.24 28.0-29.0 3200.9 167.5 2721.1 1.85 30.09 29.0-30.0 3163.2 170.8 2891.9 1.89 31.98 30.0-31.0 3122.0 173.8 3065.6 1.92 33.90 31.0-32.0 3077.0 176.3 3241.9 1.95 35.85 32.0-33.0 3032.6 178.7 3420.6 1.98 37.83 33.0-34.0 2990.1 181.0 3601.6 2.00 39.83 34.0-35.0 2946.3 183.0 3784.6 2.02 41.85 35.0-36.0 2897.9 184.5 3969.1 2.04 43.89
+86-760-88758975 Page 16 of 19 Pages Zonal Lumen (Continue 1) Gamma Imean Zonal Flux Sum Zonal Flux Rel Zonal FluxSum Rel Zonal Flux [ ] [cd] [lm] [lm] [%] [%] 36.0-37.0 2846.7 185.7 4154.8 2.05 45.95 37.0-38.0 2797.8 186.8 4341.6 2.07 48.01 38.0-39.0 2750.7 187.8 4529.4 2.08 50.09 39.0-40.0 2700.5 188.4 4717.8 2.08 52.17 40.0-41.0 2646.1 188.4 4906.2 2.08 54.26 41.0-42.0 2589.6 188.2 5094.4 2.08 56.34 42.0-43.0 2533.8 187.7 5282.1 2.08 58.41 43.0-44.0 2479.2 187.1 5469.2 2.07 60.48 44.0-45.0 2422.2 186.2 5655.4 2.06 62.54 45.0-46.0 2366.5 185.1 5840.5 2.05 64.59 46.0-47.0 2311.8 183.9 6024.4 2.03 66.62 47.0-48.0 2251.5 182.0 6206.4 2.01 68.64 48.0-49.0 2186.1 179.5 6386.0 1.99 70.62 49.0-50.0 211 176.0 6561.9 1.95 72.57 50.0-51.0 2028.8 171.7 6733.6 1.90 74.47 51.0-52.0 1955.5 167.8 6901.4 1.86 76.32 52.0-53.0 1886.7 164.1 7065.6 1.82 78.14 53.0-54.0 1814.4 159.9 7225.5 1.77 79.91 54.0-55.0 1727.4 154.2 7379.7 1.71 81.61 55.0-56.0 1645.8 148.7 7528.5 1.64 83.26 56.0-57.0 1584.2 144.9 7673.3 1.60 84.86 57.0-58.0 1501.8 138.9 7812.2 1.54 86.39 58.0-59.0 1402.7 131.2 7943.4 1.45 87.84 59.0-60.0 1299.9 122.8 8066.2 1.36 89.20 60.0-61.0 1188.5 113.4 8179.6 1.25 90.46 61.0-62.0 1091.2 105.2 8284.8 1.16 91.62 62.0-63.0 1007.3 98.0 8382.8 1.08 92.70 63.0-64.0 899.8 88.3 8471.1 0.98 93.68 64.0-65.0 803.2 79.5 8550.6 0.88 94.56 65.0-66.0 718.1 71.7 8622.3 0.79 95.35 66.0-67.0 623.7 62.7 8685.0 0.69 96.05 67.0-68.0 542.4 55.0 8739.9 0.61 96.65 68.0-69.0 458.6 46.8 8786.7 0.52 97.17 69.0-70.0 384.1 39.5 8826.2 0.44 97.61 70.0-71.0 313.8 32.4 8858.6 0.36 97.97 71.0-72.0 240.3 25.0 8883.6 8 98.24
+86-760-88758975 Page 17 of 19 Pages Zonal Lumen (Continue 2) Gamma Imean Zonal Flux Sum Zonal Flux Rel Zonal FluxSum Rel Zonal Flux [ ] [cd] [lm] [lm] [%] [%] 72.0-73.0 182.6 19.1 8902.7 1 98.45 73.0-74.0 139.0 14.6 8917.3 0.16 98.61 74.0-75.0 101.2 10.7 8928.0 0.12 98.73 75.0-76.0 69.4 7.4 8935.4 0.08 98.81 76.0-77.0 43.6 4.6 8940.0 0.05 98.87 77.0-78.0 27.2 2.9 8942.9 0.03 98.90 78.0-79.0 20.3 2.2 8945.1 0.02 98.92 79.0-80.0 18.0 1.9 8947.0 0.02 98.94 80.0-81.0 16.3 1.8 8948.8 0.02 98.96 81.0-82.0 14.7 1.6 8950.4 0.02 98.98 82.0-83.0 13.2 1.4 8951.8 0.02 99.00 83.0-84.0 11.9 1.3 8953.1 0.01 99.01 84.0-85.0 10.7 1.2 8954.3 0.01 99.02 85.0-86.0 9.5 1.0 8955.3 0.01 99.04 86.0-87.0 8.4 0.9 8956.3 0.01 99.05 87.0-88.0 7.4 0.8 8957.1 0.01 99.05 88.0-89.0 6.1 0.7 8957.7 0.01 99.06 89.0-90.0 2.9 0.3 8958.1 0.00 99.07 90.0-91.0 0.3 0.0 8958.1 0.00 99.07 91.0-92.0 0.3 0.0 8958.1 0.00 99.07 92.0-93.0 0.9 0.1 8958.2 0.00 99.07 93.0-94.0 1.3 0.1 8958.4 0.00 99.07 94.0-95.0 1.3 0.1 8958.5 0.00 99.07 95.0-96.0 2.0 8958.7 0.00 99.07 96.0-97.0 3.1 0.3 8959.1 0.00 99.08 97.0-98.0 3.6 0.4 8959.5 0.00 99.08 98.0-99.0 3.9 0.4 8959.9 0.00 99.09 99.0-100.0 4.7 0.5 8960.4 0.01 99.09 100.0-101.0 5.5 0.6 8961.0 0.01 99.10 101.0-102.0 5.8 0.6 8961.6 0.01 99.11 102.0-103.0 6.1 0.6 8962.3 0.01 99.11 103.0-104.0 6.4 0.7 8962.9 0.01 99.12 104.0-105.0 6.7 0.7 8963.6 0.01 99.13 105.0-106.0 7.3 0.8 8964.4 0.01 99.14 106.0-107.0 7.8 0.8 8965.2 0.01 99.15 107.0-108.0 8.1 0.8 8966.1 0.01 99.15
+86-760-88758975 Page 18 of 19 Pages Zonal Lumen (Continue 3) Gamma Imean Zonal Flux Sum Zonal Flux Rel Zonal FluxSum Rel Zonal Flux [ ] [cd] [lm] [lm] [%] [%] 108.0-109.0 8.5 0.9 8967.0 0.01 99.16 109.0-110.0 8.9 0.9 8967.9 0.01 99.17 110.0-111.0 9.3 1.0 8968.9 0.01 99.19 111.0-112.0 9.7 1.0 8969.8 0.01 99.20 112.0-113.0 10.0 1.0 8970.9 0.01 99.21 113.0-114.0 10.4 1.0 8971.9 0.01 99.22 114.0-115.0 10.8 1.1 8973.0 0.01 99.23 115.0-116.0 11.1 1.1 8974.1 0.01 99.24 116.0-117.0 11.5 1.1 8975.2 0.01 99.26 117.0-118.0 11.9 1.2 8976.4 0.01 99.27 118.0-119.0 12.4 1.2 8977.6 0.01 99.28 119.0-120.0 12.7 1.2 8978.8 0.01 99.29 120.0-121.0 13.0 1.2 8980.0 0.01 99.31 121.0-122.0 13.4 1.3 8981.2 0.01 99.32 122.0-123.0 13.8 1.3 8982.5 0.01 99.34 123.0-124.0 14.1 1.3 8983.8 0.01 99.35 124.0-125.0 14.5 1.3 8985.1 0.01 99.36 125.0-126.0 14.9 1.3 8986.4 0.01 99.38 126.0-127.0 15.3 1.4 8987.8 0.01 99.39 127.0-128.0 15.7 1.4 8989.2 0.02 99.41 128.0-129.0 16.1 1.4 8990.5 0.02 99.43 129.0-130.0 16.5 1.4 8991.9 0.02 99.44 130.0-131.0 16.9 1.4 8993.3 0.02 99.46 131.0-132.0 17.2 1.4 8994.8 0.02 99.47 132.0-133.0 17.6 1.4 8996.2 0.02 99.49 133.0-134.0 18.0 1.4 8997.6 0.02 99.50 134.0-135.0 18.4 1.4 8999.1 0.02 99.52 135.0-136.0 18.8 1.4 9000.5 0.02 99.54 136.0-137.0 19.2 1.4 9001.9 0.02 99.55 137.0-138.0 19.6 1.5 9003.4 0.02 99.57 138.0-139.0 19.9 1.4 9004.8 0.02 99.58 139.0-140.0 2 1.4 9006.3 0.02 99.60 140.0-141.0 20.6 1.4 9007.7 0.02 99.62 141.0-142.0 21.0 1.4 9009.2 0.02 99.63 142.0-143.0 21.3 1.4 9010.6 0.02 99.65 143.0-144.0 21.6 1.4 9012.0 0.02 99.66
+86-760-88758975 Page 19 of 19 Pages Zonal Lumen (Continue 4) Gamma Imean Zonal Flux Sum Zonal Flux Rel Zonal FluxSum Rel Zonal Flux [ ] [cd] [lm] [lm] [%] [%] 144.0-145.0 22.0 1.4 9013.4 0.02 99.68 145.0-146.0 22.3 1.4 9014.8 0.02 99.69 146.0-147.0 22.6 1.4 9016.1 0.02 99.71 147.0-148.0 23.0 1.4 9017.5 0.01 99.72 148.0-149.0 23.4 1.3 9018.8 0.01 99.74 149.0-150.0 23.7 1.3 902 0.01 99.75 150.0-151.0 23.9 1.3 9021.5 0.01 99.77 151.0-152.0 24.2 1.3 9022.7 0.01 99.78 152.0-153.0 24.5 1.2 9024.0 0.01 99.79 153.0-154.0 24.8 1.2 9025.2 0.01 99.81 154.0-155.0 25.1 1.2 9026.4 0.01 99.82 155.0-156.0 25.4 1.2 9027.5 0.01 99.83 156.0-157.0 25.7 1.1 9028.6 0.01 99.85 157.0-158.0 26.0 1.1 9029.7 0.01 99.86 158.0-159.0 26.3 1.1 9030.8 0.01 99.87 159.0-160.0 26.6 1.0 9031.8 0.01 99.88 160.0-161.0 26.8 1.0 9032.8 0.01 99.89 161.0-162.0 27.2 0.9 9033.7 0.01 99.90 162.0-163.0 27.5 0.9 9034.6 0.01 99.91 163.0-164.0 27.7 0.9 9035.5 0.01 99.92 164.0-165.0 28.0 0.8 9036.3 0.01 99.93 165.0-166.0 28.2 0.8 9037.1 0.01 99.94 166.0-167.0 28.4 0.7 9037.8 0.01 99.95 167.0-168.0 28.7 0.7 9038.5 0.01 99.96 168.0-169.0 28.9 0.6 9039.1 0.01 99.96 169.0-170.0 29.0 0.6 9039.7 0.01 99.97 170.0-171.0 29.2 0.5 904 0.01 99.97 171.0-172.0 29.4 0.5 9040.7 0.01 99.98 172.0-173.0 29.5 0.4 9041.1 0.00 99.98 173.0-174.0 29.6 0.4 9041.5 0.00 99.99 174.0-175.0 29.7 0.3 9041.8 0.00 99.99 175.0-176.0 29.8 0.3 9042.1 0.00 99.99 176.0-177.0 29.8 9042.3 0.00 100.00 177.0-178.0 29.9 0.1 9042.4 0.00 100.00 178.0-179.0 29.9 0.1 9042.5 0.00 100.00 179.0-180.0 29.9 0.0 9042.5 0.00 100.00