Page: 1 of 8 Date: April 14, 2010 WINMATE COMMUNICATION INC. 9 F, NO. 111-6, SHING-DE RD., SAN-CHUNG CITY, TAIPEI, TAIWAN, R.O.C. The following merchandise was submitted and identified by the vendor as: Product Description: 20.1 Multimedia LCD Monitor Style/ Item No.: R20L100-RKA2XX/ No. 1 Quantity: Total 1 set Testing Period: Apr. 7, 2010 to Apr. 8, 2010 We have tested the submitted sample(s) as requested and the following results were obtained: Test Required: (According to client s test specification, please see following sheets in detail.) 1. Vibration Test Test Results: -PLEASE SEE ATTACHED SHEETS- Terence Hsieh Manager - Operation
Page: 2 of 8 1. Vibration Test: Test Equipment: Name Brand Model Serial No. Vibration Test System UNHOLTZ-DICKIE SAI60-H560BAC/2/ST 474 Controller Dactron LASER 7110357 Control Accelerometer PCB 353B34 139173 Lab Environmental Conditions: Ambient temperature: 25±3 Relative humidity: 55±20%RH Test Method/ Specification: Test Method: Reference to MIL-STD-810G, Method 514.6 Testing Procedures Ⅰ, Table 514.6C-VI, Category-4 Composite wheeled vehicle vibration exposures. (Break points for curves of Figure 514.6C-3) Sample Condition: Packaged Wave form: Random Frequency: 5~500 Hz (Test Spectrums as shown in the following sheets in detail) Impact acceleration: 1.48 & 1.90 & 2.24 Grms Direction: X, Y, Z axes (See photo 7 ~ 9) Duration: 1 hour/ axis Examine the appearance of specimen(s) by visual check and perform functional check after this test. Functional check: Connect the specimen with rated power then examine whether the display function of specimen could be work normally or not. Place the product on the vibration table in its normal operating orientation and configuration. The Product shall be no fixture to the vibration table such that the vibratory input is transmitted directly to the product. Operating the product during the test. Vibrate the product up the frequency range at a rate of 5 to 500 Hz. At the appropriate level in the table of test condition in each of three orthogonal axes. The test shall last approximately 60 minutes per axis. Equivalent to 1.48 & 1.90 & 2.24 Grms. Document the result during the test. The functional and electrical check is required, document the result after the check. Performance check: Running Window XP with stress software BCM diagnostics Pro version 2.30.
Page: 3 of 8 Test Method/ Specification--Continued: Test Spectrums: Vertical - Z axis Transverse - X axis Longitudinal - Y axis Frequency (Hz) PSD (g 2 /Hz) Frequency (Hz) PSD (g 2 /Hz) Frequency (Hz) PSD (g 2 /Hz) 5 0.1759 5 0.0998 5 0.0441 8 0.5120 7 0.0799 7 0.0390 11 0.0660 9 0.1115 8 0.0576 12 0.0585 10 0.0577 9 0.0430 13 0.0348 14 0.0294 10 0.0293 15 0.1441 15 0.0651 13 0.0221 16 0.1237 16 0.0646 15 0.0558 20 0.0241 17 0.0436 16 0.0585 23 0.0536 18 0.0393 18 0.0160 26 0.0124 19 0.0622 20 0.0099 27 0.0118 24 0.0100 23 0.0452 30 0.0331 37 0.0045 25 0.0110 34 0.0086 38 0.0065 35 0.0036 39 0.0347 44 0.0033 37 0.0098 43 0.0073 55 0.0024 40 0.0040 45 0.0141 57 0.0042 41 0.0044 49 0.0084 59 0.0019 45 0.0023 52 0.0089 76 0.0012 47 0.0047 57 0.0045 79 0.0021 50 0.0016 67 0.0160 83 0.0010 54 0.0017 80 0.0037 114 0.0006 64 0.0010 90 0.0077 135 0.0017 69 0.0030 93 0.0053 142 0.0010 77 0.0007 98 0.0065 158 0.0018 85 0.0015 99 0.0063 185 0.0010 90 0.0012 111 0.0046 191 0.0007 97 0.0015 123 0.0069 206 0.0008 104 0.0036 128 0.0055 273 0.0035 114 0.0040 164 0.0031 300 0.0016 122 0.0015 172 0.0035 364 0.0074 132 0.0013 215 0.0133 374 0.0022 206 0.0033 264 0.0056 395 0.0051 247 0.0226 276 0.0096 500 0.0012 257 0.0041 292 0.0032 equivalent to 1.48 G rms 264 0.0054 348 0.0044 276 0.0040 417 0.0031 303 0.0073 500 0.0008 332 0.0092 equivalent to 2.24 G rms 353 0.0172 382 0.0071 428 0.0157 500 0.0016 equivalent to 1.90 G rms
Page: 4 of 8 Specimen: Style/ Item No.: R20L100-RKA2XX/ No. 1 Quantity: total 1 set Test Result: Style/Item No. Check Item Appearance check (Visual check) Functional Check & Performance Check R20L100-RKA2XX/ No. 1 No visible damage Normal
Page: 5 of 8 Test Photos: 1. Appearance of specimen 2. Appearance of specimen 3. Appearance of specimen 4. Appearance of specimen 5. Appearance of specimen 6. Appearance of specimen
Page: 6 of 8 Test Photos--Continued: 7. Vibration Test -- X axis 8. Vibration Test -- Y axis 9. Vibration Test -- Z axis 10. Functional check 11. Functional check
Page: 7 of 8 Test Photos--Continued: (gn)2/hz 0.9727 0.1000 0.0100 profile(f) high-abort(f) low-abort(f) high-alarm(f) low-alarm(f) control(f) 0.0010 0.0001 3.98E-05 5.63 10.00 100.00 Frequency (Hz) (gn)2/hz 0.4898 0.1000 12. Frequency response spectrum: X axis 500.00 profile(f) high-abort(f) low-abort(f) high-alarm(f) low-alarm(f) 0.0100 control(f) 0.0010 0.0001 6.31E-05 5.63 10.00 100.00 Frequency (Hz) 13. Frequency response spectrum: Y axis 500.00
Page: 8 of 8 Test Photos--Continued: (gn)2/hz 4.8978 1.0000 0.1000 profile(f) high-abort(f) low-abort(f) high-alarm(f) low-alarm(f) control(f) 0.0100 0.0010 0.0001 6.31E-05 5.63 10.00 100.00 Frequency (Hz) 14. Frequency response spectrum: Z axis 500.00 The End of Test Report