+86-760-88758975 Page 1 of 19 Pages Report No.: 32 Test Time: 2017/11/23 13:44 Luminaire Property Luminaire Manufacturer: Luminaire Description: 乳白 Voltage: 220V Current: 0.163 A Power: 17.88W Power Factor: 0.501 Photometric Results CIE Class: Semi-Direct Total Rated Lamp Lumens: 1676.3 lm Measurement Flux: 1676.3 lm Efficiency: 100% Downward Ratio: 87% Upward Ratio: 13% Horizontal Diffuse Angle(50%): H111.4 Vertical Diffuse Angle(50%): V153.5 Luminaire Efficacy Rating (LER): 93.80 Central Intensity: 410.52 cd Max. Intensity: 410.52 cd Pos of Max. Intensity: H0 V0 S/MH(C0/C180): 1.25 S/MH(C90/C270): 1.34 Picture Of Luminaire Luminous Intensity Distribution Curve 160 170 150 140 130 120 110 100 180 170 160 150 140 130 120 110 100 90 90 102 80 80 70 205 70 60 307 60 50 410 50 40 40 30 513 30 20 10 0 10 20 Unit: cd Average Diffuse Angle(50%): 132.4 C0-C180 C90-C270 G0
+86-760-88758975 Page 2 of 19 Pages Luminous Intensity Distribution Curve 170 160 150 140 130 120 110 100 180 170 160 150 140 130 120 110 100 90 90 80 70 60 102 205 307 80 70 60 50 40 30 20 10 410 513 0 10 20 30 50 40 513 410 307 205 102 0-180 -120-60 0 60 120 180 C0-C180 C90-C270 Unit: cd
+86-760-88758975 Page 3 of 19 Pages Luminous Intensity Distribution Curve(cd/klm) 150 160 170 180 170 160 150 140 140 130 130 120 120 110 110 100 100 90 90 80 61 80 70 122 70 60 183 60 50 40 244 40 50 30 cd/klm C0-C180 C90-C270 20 10 306 0 10 20 30 η=100%
RC RW RCR 0 1 2 3 4 5 6 7 8 9 10 杭州创惠仪器有限公司 +86-760-88758975 Page 4 of 19 Pages Coefficients Of Utilization - Zonal Cavity Method 0.8 0.8 0.8 0.8 0.7 0.7 0.7 0.7 0.5 0.5 0.5 0.3 0.3 0.3 0.1 0.1 0.1 0 0.7 0.5 0.3 0.1 0.7 0.5 0.3 0.1 0.5 0.3 0.1 0.5 0.3 0.1 0.5 0.3 0.1 0 Spacing Criteria (0-180): 1.25 Spacing Criteria (90-270): 1.34 Spacing Criteria (Diagonal): 1.43 N 30 25 20 RF = 116 116 116 116 112 112 112 112 104 104 104 97 97 97 90 90 90 87 103 97 92 87 99 94 89 84 87 83 79 81 77 75 75 72 70 67 93 83 75 69 89 80 73 67 74 68 63 69 64 60 64 60 57 54 84 72 63 56 80 70 61 55 65 58 52 60 54 50 56 51 47 44 76 63 54 47 73 61 53 46 57 50 44 53 47 42 50 44 40 37 70 56 47 40 67 54 46 39 51 43 37 47 41 36 44 39 34 32 65 51 41 34 62 49 40 34 46 38 32 43 36 31 40 34 30 27 60 46 37 30 57 44 36 30 41 34 28 39 32 27 36 31 26 24 55 41 33 27 53 40 32 26 38 31 25 36 29 24 33 28 23 21 52 38 30 24 50 37 29 23 35 28 23 33 26 22 31 25 21 19 48 35 27 21 47 34 26 21 32 25 20 30 24 20 29 23 19 17 Curves of Luminaires vs Lighting Area 15 H=12 H=2 10 H=10 H=7 8 7 6 Luminous Flux 5000 lm 5 Maintain Factor 0.70 4 Suspend Length 0.00m Work Height 0.80m 3 Average Lux 100 lx Reflectivity(%) Line Type Ceil Wall Floor 70 50 30 2 10 2 2 3 4 5 6 7 8 910 3 2 3 4 5 6 7 8 910 4 A(sq.m) H=5 H=3
+86-760-88758975 Page 5 of 19 Pages Isocandela (rectangle) 80 21 60 40 62 82 41 103 Vertical(Deg) 20 0-20 205 308 411-40 -60-80 -80-60 -40-20 0 20 40 60 80 Horizontal(Deg) Imax (100%): 411 cd ( 5%): 21 cd ( 10%): 41 cd ( 15%): 62 cd ( 20%): 82 cd ( 25%): 103 cd ( 50%): 205 cd ( 75%): 308 cd (100%): 411 cd
+86-760-88758975 Page 6 of 19 Pages IsoLux Plot 5 2 4 3 2 2 Horizontal(m) 1 0 1 3 3 4 2 3 4 5 5 4 3 2 1 0 1 2 3 4 5 Vertical(m) Mounting Height: 10.0m Max Lux(100%): 4.1 lx ( 50%): 2.1 lx ( 60%): 2.5 lx ( 70%): 2.9 lx ( 80%): 3.3 lx ( 90%): 3.7 lx (100%): 4.1 lx
+86-760-88758975 Page 7 of 19 Pages Lum Limit Curve Dazzle Quality Illuminance (lx) 1.15 A 2000 1000 500 <=300 1.50 B 2000 1000 500 <=300 1.85 C 2000 1000 500 <=300 2.20 D 2000 1000 500 <=300 2.55 E 2000 1000 500 <=300 a b c d e f g h Gamma 85 75 65 a b c d e f g h 8 6 4 a/hs 3 2 55 45 6 7 8 9 1000 2 3 4 5 6 7 8 9 10000 2 3 4 C90 C270 L(cd/sq.m) Gamma 85 75 65 55 a b c d e f g h 8 6 4 a/hs 3 2 45 6 7 8 9 1000 2 3 4 5 6 7 8 9 10000 2 3 4 C0 C180 L(cd/sq.m) L(cd/sq.m) G45 G50 G55 G60 G65 G70 G75 G80 G85 C0 271 242 211 179 144 110 77 44 16 C90 311 293 275 256 237 218 199 180 162 C180 269 240 208 175 141 106 73 40 14 C270 331 314 296 278 259 240 221 202 183
+86-760-88758975 Page 8 of 19 Pages Illuminance at a Distance Dist(m) Enadir(lx) Dh/Dv_B(m) S_B(sq.m) Eav_B(lx) 1.0 410.52 2.93/8.48 23.2 26.76 2.0 102.63 5.86/16.96 92.7 6.69 3.0 45.61 8.80/25.44 208.6 2.97 4.0 25.66 11.73/33.92 370.9 1.67 5.0 16.42 14.66/42.40 579.5 1.07 6.0 11.40 17.59/50.88 834.4 0.74 7.0 8.38 20.53/59.36 1135.7 0.55 8.0 6.41 23.46/67.84 1483.4 0.42 10.0 4.11 29.32/84.80 2317.9 7 Dh 12.0 2.85 35.19/101.76 3337.7 0.19 Dv Beam Angle(B): H111.4 V153.5 Field Angle(F): H160.4 V256.7
+86-760-88758975 Page 9 of 19 Pages Vertical IsoLux Plot 1 246 205 2 3 4 Vertical Height(m) 5 6 7 8 9 10 11 0 1 2 3 4 5 6 7 8 9 10 Horizontal distance(m) Lowest(m): 1.0m Highest(m): 11.0m Max Lux: 410.5 lx ( 50%): 205.3 lx ( 60%): 246.3 lx ( 70%): 287.4 lx ( 80%): 328.4 lx ( 90%): 369.5 lx (100%): 410.5 lx
+86-760-88758975 Page 10 of 19 Pages The Average Illuminance Effective Figure Flux Out: 889.35lm 1.0m 131.69/ 410.52lx 2.93m / 6.75sq.m 2.0m 32.92/ 102.63lx 5.86m / 27.01sq.m 3.0m 14.63/ 45.61lx 8.80m / 60.78sq.m 4.0m 8.23/ 25.66lx 11.73m / 108.06sq.m 5.0m 5.27/ 16.42lx 14.66m / 168.84sq.m 6.0m 3.66/ 11.40lx 17.59m / 243.13sq.m 7.0m 2.69/ 8.38lx 20.53m / 330.92sq.m 8.0m 2.06/ 6.41lx 23.46m / 432.22sq.m 10.0m 1.32/ 4.11lx 29.32m / 675.35sq.m 12.0m 0.91/ 2.85lx 35.19m / 972.50sq.m Height Avg./Nadir. E Beam Angle:111.4 Diameter / Area
+86-760-88758975 Page 11 of 19 Pages UGR Table Reflectance: Ceiling (cavity) 0.7 0.7 0.5 0.5 0.3 0.7 0.7 0.5 0.5 0.3 Wall 0.5 0.3 0.5 0.3 0.3 0.5 0.3 0.5 0.3 0.3 Reference plane Room dimensions X=2H Y=2H 3H 4H 6H 8H 12H X=4H Y=2H 3H 4H 6H 8H 12H X=8H Y=4H 6H 8H 12H X=12H Y=4H 6H 8H Viewed crosswise Viewed endwise Variations with the observer position at spacings: S=1.0H -1.$/-1.$ -1.$/-1.$ S=1.5H -1.$/-1.$ -1.$/-1.$ S=2.0H -1.$/-1.$ -1.$/-1.$ Calculate in accordance with CIE Pub.117. The table is revised with 1676lm (8log(F/F0) = 1.8).
+86-760-88758975 Page 12 of 19 Pages Utilisation Factor Table(Floor cavity) Utilisation Factors UF(F) SHR NOM = 1.50 Room Reflectance Room Index(RI) Ceiling Wall Floor 0.75 1.00 1.25 1.50 2.00 2.50 3.00 4.00 5.00 0.70 0.50 0 0.51 0.59 0.66 0.71 0.78 0.83 0.87 0.92 0.95 0.30 0.43 0.51 0.58 0.63 0.71 0.77 0.81 0.87 0.91 0 0.37 0.45 0.52 0.57 0.65 0.71 0.76 0.82 0.87 0.50 0.50 0 0.48 0.55 0.62 0.67 0.73 0.78 0.81 0.85 0.88 0.30 0.41 0.48 0.55 0.60 0.67 0.72 0.76 0.81 0.85 0 0.36 0.43 0.50 0.55 0.62 0.68 0.72 0.78 0.82 0.30 0.50 0 0.46 0.52 0.58 0.62 0.68 0.72 0.75 0.79 0.82 0.30 0.40 0.46 0.52 0.57 0.63 0.68 0.71 0.76 0.79 0 0.35 0.41 0.48 0.52 0.59 0.64 0.68 0.73 0.77 0.00 0.00 0.00 0.32 0.37 0.43 0.47 0.54 0.58 0.61 0.66 0.69 Rating:18W Photometrically tested without ceiling board. Multiply UF values by service correction factors Calculate in accordance with CIBSE Technical Memorandum NO.5 1980
+86-760-88758975 Page 13 of 19 Pages Utilisation Factor Table(Wall) Utilisation Factors UF(W) SHR NOM = 1.50 Room Reflectance Room Index(RI) Ceiling Wall Floor 0.75 1.00 1.25 1.50 2.00 2.50 3.00 4.00 5.00 0.70 0.50 0 1.01 0.87 0.76 0.67 0.55 0.47 0.41 0.33 7 0.30 0.84 0.75 0.66 0.59 0.50 0.43 0.38 0.31 6 0 0.72 0.65 0.58 0.53 0.45 0.40 0.35 9 5 0.50 0.50 0 0.95 0.82 0.71 0.63 0.52 0.46 0.38 0.31 6 0.30 0.80 0.71 0.63 0.56 0.47 0.41 0.36 9 5 0 0.70 0.63 0.56 0.51 0.43 0.38 0.34 8 4 0.30 0.50 0 0.90 0.77 0.66 0.59 0.48 0.41 0.36 9 4 0.30 0.77 0.68 0.59 0.53 0.45 0.39 0.34 8 3 0 0.67 0.60 0.54 0.49 0.41 0.36 0.32 6 2 0.00 0.00 0.00 0.56 0.50 0.44 0.40 0.34 9 6 1 0.18 Rating:18W Photometrically tested without ceiling board. Multiply UF values by service correction factors Calculate in accordance with CIBSE Technical Memorandum NO.5 1980
+86-760-88758975 Page 14 of 19 Pages Utilisation Factor Table(Ceiling cavity) Utilisation Factors UF(C) SHR NOM = 1.50 Room Reflectance Room Index(RI) Ceiling Wall Floor 0.75 1.00 1.25 1.50 2.00 2.50 3.00 4.00 5.00 0.70 0.50 0 9 0.30 0.31 0.32 0.33 0.33 0.34 0.34 0.34 0.30 2 3 5 6 7 8 9 0.30 0.31 0 0.17 0.18 0 1 3 4 5 7 8 0.50 0.50 0 8 9 0.30 0.31 0.31 0.32 0.32 0.33 0.33 0.30 2 3 4 5 6 7 8 9 0.30 0 0.17 0.18 0.19 0 2 4 5 6 7 0.30 0.50 0 7 8 9 0.30 0.30 0.31 0.31 0.31 0.32 0.30 1 2 4 4 6 7 7 8 9 0 0.17 0.18 0.19 0 2 3 4 5 6 0.00 0.00 0.00 0.13 0.13 0.13 0.13 0.13 0.13 0.13 0.13 0.13 Rating:18W Photometrically tested without ceiling board. Multiply UF values by service correction factors Calculate in accordance with CIBSE Technical Memorandum NO.5 1980
+86-760-88758975 Page 15 of 19 Pages Zonal Lumen Gamma Imean Zonal Flux Sum Zonal Flux Rel Zonal FluxSum Rel Zonal Flux [ ] [cd] [lm] [lm] [%] [%] 0.0-1.0 407.6 0.4 0.4 0.02 0.02 1.0-2.0 407.4 1.2 1.6 0.07 0.09 2.0-3.0 407.2 1.9 3.5 0.12 1 3.0-4.0 406.8 2.7 6.2 0.16 0.37 4.0-5.0 406.3 3.5 9.7 1 0.58 5.0-6.0 405.7 4.3 14.0 5 0.83 6.0-7.0 404.9 5.0 19.0 0.30 1.13 7.0-8.0 404.1 5.8 24.8 0.35 1.48 8.0-9.0 403.1 6.5 31.3 0.39 1.87 9.0-10.0 402.0 7.3 38.6 0.43 2.30 10.0-11.0 400.7 8.0 46.6 0.48 2.78 11.0-12.0 399.4 8.7 55.3 0.52 3.30 12.0-13.0 397.9 9.4 64.8 0.56 3.87 13.0-14.0 396.3 10.1 74.9 0.61 4.47 14.0-15.0 394.7 10.8 85.8 0.65 5.12 15.0-16.0 392.9 11.5 97.3 0.69 5.80 16.0-17.0 391.0 12.2 109.5 0.73 6.53 17.0-18.0 388.9 12.8 122.3 0.77 7.30 18.0-19.0 386.8 13.5 135.7 0.80 8.10 19.0-20.0 384.5 14.1 149.8 0.84 8.94 20.0-21.0 382.2 14.7 164.5 0.88 9.81 21.0-22.0 379.8 15.3 179.8 0.91 10.72 22.0-23.0 377.2 15.8 195.6 0.94 11.67 23.0-24.0 374.5 16.4 212.0 0.98 12.65 24.0-25.0 371.7 16.9 228.9 1.01 13.65 25.0-26.0 368.8 17.4 246.3 1.04 14.69 26.0-27.0 365.8 17.9 264.2 1.07 15.76 27.0-28.0 362.8 18.4 282.6 1.10 16.86 28.0-29.0 359.7 18.8 301.4 1.12 17.98 29.0-30.0 356.4 19.2 320.6 1.15 19.13 30.0-31.0 353.1 19.7 340.3 1.17 20.30 31.0-32.0 349.6 20.0 360.3 1.19 21.49 32.0-33.0 346.0 20.4 380.7 1.22 22.71 33.0-34.0 342.5 20.7 401.4 1.24 23.95 34.0-35.0 338.9 21.0 422.5 1.26 25.20 35.0-36.0 335.2 21.3 443.8 1.27 26.48
+86-760-88758975 Page 16 of 19 Pages Zonal Lumen (Continue 1) Gamma Imean Zonal Flux Sum Zonal Flux Rel Zonal FluxSum Rel Zonal Flux [ ] [cd] [lm] [lm] [%] [%] 36.0-37.0 331.3 21.6 465.4 1.29 27.77 37.0-38.0 327.3 21.9 487.3 1.30 29.07 38.0-39.0 323.3 22.1 509.4 1.32 30.39 39.0-40.0 319.3 22.3 531.6 1.33 31.71 40.0-41.0 315.2 22.4 554.1 1.34 33.05 41.0-42.0 311.0 22.6 576.7 1.35 34.40 42.0-43.0 306.8 22.7 599.4 1.36 35.76 43.0-44.0 302.5 22.8 622.2 1.36 37.12 44.0-45.0 298.1 22.9 645.1 1.37 38.49 45.0-46.0 293.7 23.0 668.1 1.37 39.86 46.0-47.0 289.2 23.0 691.1 1.37 41.23 47.0-48.0 284.7 23.0 714.1 1.37 42.60 48.0-49.0 28 23.0 737.1 1.37 43.98 49.0-50.0 275.6 23.0 760.1 1.37 45.35 50.0-51.0 270.8 22.9 783.0 1.37 46.71 51.0-52.0 266.1 22.8 805.9 1.36 48.08 52.0-53.0 261.5 22.7 828.6 1.36 49.43 53.0-54.0 256.7 22.6 851.3 1.35 50.78 54.0-55.0 251.9 22.5 873.7 1.34 52.12 55.0-56.0 247.1 22.3 896.1 1.33 53.46 56.0-57.0 242.2 22.1 918.2 1.32 54.78 57.0-58.0 237.3 22.0 94 1.31 56.09 58.0-59.0 232.5 21.7 961.9 1.30 57.38 59.0-60.0 227.6 21.5 983.4 1.28 58.67 60.0-61.0 222.6 21.2 1004.7 1.27 59.93 61.0-62.0 217.6 21.0 1025.6 1.25 61.18 62.0-63.0 212.7 20.7 1046.3 1.23 62.42 63.0-64.0 207.7 20.4 1066.7 1.22 63.63 64.0-65.0 202.8 20.1 1086.8 1.20 64.83 65.0-66.0 197.9 19.7 1106.5 1.18 66.01 66.0-67.0 193.0 19.4 1125.9 1.16 67.17 67.0-68.0 188.0 19.0 1145.0 1.14 68.30 68.0-69.0 183.0 18.7 1163.6 1.11 69.42 69.0-70.0 178.1 18.3 1181.9 1.09 70.51 70.0-71.0 173.2 17.9 1199.8 1.07 71.58 71.0-72.0 168.3 17.5 1217.3 1.04 72.62
+86-760-88758975 Page 17 of 19 Pages Zonal Lumen (Continue 2) Gamma Imean Zonal Flux Sum Zonal Flux Rel Zonal FluxSum Rel Zonal Flux [ ] [cd] [lm] [lm] [%] [%] 72.0-73.0 163.4 17.1 1234.4 1.02 73.64 73.0-74.0 158.7 16.7 1251.1 1.00 74.64 74.0-75.0 153.9 16.3 1267.4 0.97 75.61 75.0-76.0 149.3 15.8 1283.2 0.95 76.55 76.0-77.0 144.5 15.4 1298.6 0.92 77.47 77.0-78.0 139.8 15.0 1313.6 0.89 78.36 78.0-79.0 135.2 14.5 1328.1 0.87 79.23 79.0-80.0 130.7 14.1 1342.2 0.84 80.07 80.0-81.0 126.4 13.7 1355.9 0.82 80.89 81.0-82.0 121.9 13.2 1369.1 0.79 81.68 82.0-83.0 117.6 12.8 1381.9 0.76 82.44 83.0-84.0 113.5 12.4 1394.3 0.74 83.18 84.0-85.0 109.5 12.0 1406.2 0.71 83.89 85.0-86.0 105.6 11.5 1417.8 0.69 84.58 86.0-87.0 101.9 11.2 1428.9 0.67 85.24 87.0-88.0 98.4 10.8 1439.7 0.64 85.89 88.0-89.0 95.2 10.4 145 0.62 86.51 89.0-90.0 92.2 10.1 1460.3 0.60 87.11 90.0-91.0 89.4 9.8 1470.1 0.58 87.70 91.0-92.0 86.8 9.5 1479.6 0.57 88.27 92.0-93.0 84.3 9.2 1488.8 0.55 88.82 93.0-94.0 81.9 9.0 1497.8 0.53 89.35 94.0-95.0 79.4 8.7 1506.5 0.52 89.87 95.0-96.0 77.0 8.4 1514.9 0.50 90.37 96.0-97.0 74.7 8.1 1523.0 0.49 90.86 97.0-98.0 72.4 7.9 1530.9 0.47 91.33 98.0-99.0 70.1 7.6 1538.5 0.45 91.78 99.0-100.0 67.9 7.3 1545.8 0.44 92.22 100.0-101.0 65.7 7.1 1552.9 0.42 92.64 101.0-102.0 63.1 6.8 1559.7 0.40 93.04 102.0-103.0 58.8 6.3 1566.0 0.38 93.42 103.0-104.0 53.4 5.7 1571.7 0.34 93.76 104.0-105.0 49.7 5.3 1577.0 0.31 94.07 105.0-106.0 47.5 5.0 1582.0 0.30 94.37 106.0-107.0 45.9 4.8 1586.8 9 94.66 107.0-108.0 43.7 4.6 1591.4 7 94.93
+86-760-88758975 Page 18 of 19 Pages Zonal Lumen (Continue 3) Gamma Imean Zonal Flux Sum Zonal Flux Rel Zonal FluxSum Rel Zonal Flux [ ] [cd] [lm] [lm] [%] [%] 108.0-109.0 41.1 4.3 1595.6 6 95.19 109.0-110.0 39.5 4.1 1599.7 4 95.43 110.0-111.0 38.3 3.9 1603.7 3 95.67 111.0-112.0 37.1 3.8 1607.5 3 95.89 112.0-113.0 35.9 3.6 1611.1 2 96.11 113.0-114.0 35.7 3.6 1614.7 1 96.33 114.0-115.0 35.6 3.6 1618.2 1 96.54 115.0-116.0 34.7 3.4 1621.7 0 96.74 116.0-117.0 33.6 3.3 1625.0 0 96.94 117.0-118.0 32.3 3.1 1628.1 0.19 97.13 118.0-119.0 31.0 3.0 1631.1 0.18 97.30 119.0-120.0 29.7 2.8 1633.9 0.17 97.47 120.0-121.0 28.4 2.7 1636.6 0.16 97.63 121.0-122.0 27.2 2.5 1639.2 0.15 97.79 122.0-123.0 26.0 2.4 1641.6 0.14 97.93 123.0-124.0 24.8 2.3 1643.8 0.14 98.06 124.0-125.0 23.7 2.1 1646.0 0.13 98.19 125.0-126.0 22.7 2.0 1648.0 0.12 98.31 126.0-127.0 21.6 1.9 1649.9 0.11 98.43 127.0-128.0 20.6 1.8 1651.7 0.11 98.53 128.0-129.0 19.7 1.7 1653.4 0.10 98.63 129.0-130.0 18.8 1.6 1655.0 0.09 98.73 130.0-131.0 18.0 1.5 1656.5 0.09 98.82 131.0-132.0 17.2 1.4 1657.9 0.08 98.90 132.0-133.0 16.4 1.3 1659.2 0.08 98.98 133.0-134.0 15.8 1.3 1660.5 0.07 99.06 134.0-135.0 15.1 1.2 1661.7 0.07 99.13 135.0-136.0 14.3 1.1 1662.8 0.07 99.19 136.0-137.0 13.6 1.0 1663.8 0.06 99.25 137.0-138.0 13.0 1.0 1664.7 0.06 99.31 138.0-139.0 12.4 0.9 1665.6 0.05 99.37 139.0-140.0 11.8 0.8 1666.5 0.05 99.42 140.0-141.0 11.2 0.8 1667.3 0.05 99.46 141.0-142.0 10.7 0.7 1668.0 0.04 99.51 142.0-143.0 1 0.7 1668.7 0.04 99.55 143.0-144.0 9.7 0.6 1669.3 0.04 99.58
+86-760-88758975 Page 19 of 19 Pages Zonal Lumen (Continue 4) Gamma Imean Zonal Flux Sum Zonal Flux Rel Zonal FluxSum Rel Zonal Flux [ ] [cd] [lm] [lm] [%] [%] 144.0-145.0 9.3 0.6 1669.9 0.04 99.62 145.0-146.0 8.8 0.5 1670.5 0.03 99.65 146.0-147.0 8.3 0.5 1671.0 0.03 99.68 147.0-148.0 8.0 0.5 1671.4 0.03 99.71 148.0-149.0 7.6 0.4 1671.9 0.03 99.74 149.0-150.0 7.3 0.4 1672.3 0.02 99.76 150.0-151.0 6.9 0.4 1672.6 0.02 99.78 151.0-152.0 6.6 0.3 1673.0 0.02 99.80 152.0-153.0 6.3 0.3 1673.3 0.02 99.82 153.0-154.0 6.0 0.3 1673.6 0.02 99.84 154.0-155.0 5.7 0.3 1673.9 0.02 99.86 155.0-156.0 5.5 1674.1 0.01 99.87 156.0-157.0 5.2 1674.4 0.01 99.88 157.0-158.0 5.0 1674.6 0.01 99.90 158.0-159.0 4.7 1674.8 0.01 99.91 159.0-160.0 4.5 1674.9 0.01 99.92 160.0-161.0 4.3 1675.1 0.01 99.93 161.0-162.0 4.1 0.1 1675.2 0.01 99.94 162.0-163.0 4.0 0.1 1675.4 0.01 99.94 163.0-164.0 3.8 0.1 1675.5 0.01 99.95 164.0-165.0 3.7 0.1 1675.6 0.01 99.96 165.0-166.0 3.5 0.1 1675.7 0.01 99.96 166.0-167.0 3.4 0.1 1675.8 0.01 99.97 167.0-168.0 3.3 0.1 1675.8 0.00 99.97 168.0-169.0 3.3 0.1 1675.9 0.00 99.98 169.0-170.0 3.2 0.1 1676.0 0.00 99.98 170.0-171.0 3.2 0.1 1676.0 0.00 99.99 171.0-172.0 3.2 0.1 1676.1 0.00 99.99 172.0-173.0 3.2 0.0 1676.1 0.00 99.99 173.0-174.0 3.2 0.0 1676.2 0.00 99.99 174.0-175.0 3.2 0.0 1676.2 0.00 100.00 175.0-176.0 3.2 0.0 1676.2 0.00 100.00 176.0-177.0 3.2 0.0 1676.3 0.00 100.00 177.0-178.0 3.2 0.0 1676.3 0.00 100.00 178.0-179.0 3.2 0.0 1676.3 0.00 100.00 179.0-180.0 3.2 0.0 1676.3 0.00 100.00