+86-760-88758975 Page 1 of 19 Pages Report No.: 23 Test Time: 2017/11/30 11:07 Luminaire Property Luminaire Manufacturer: Luminaire Description: SMD-WANT-SS-200 Current: 0.923 A Power Factor: 0.987 Photometric Results Voltage: 220V Power: 200W CIE Class: Direct Total Rated Lamp Lumens: 17519.2 lm Measurement Flux: 17519.2 lm Efficiency: 100% Downward Ratio: 99% Upward Ratio: 1% Horizontal Diffuse Angle(50%): H101.4 Vertical Diffuse Angle(50%): V106.2 Luminaire Efficacy Rating (LER): 87.65 Central Intensity: 7298.7 cd Max. Intensity: 7322.65 cd Pos of Max. Intensity: H180 V9 S/MH(C0/C180): 1.28 S/MH(C90/C270): 1.24 Picture Of Luminaire 90 Luminous Intensity Distribution Curve 160 170 150 140 130 120 110 100 80 70 60 180 1830 3661 5491 170 160 150 140 130 120 60 110 100 90 80 70 50 7322 50 40 40 30 9153 30 20 10 0 10 20 Unit: cd Average Diffuse Angle(50%): 103.8 C0-C180 C90-C270 G9
9153 7322 5491 3661 1830 杭州创惠仪器有限公司 +86-760-88758975 Page 2 of 19 Pages Luminous Intensity Distribution Curve 90 170 160 150 140 130 120 110 100 80 70 60 50 40 30 20 10 180 1830 3661 5491 7322 9153 0 170 160 150 140 130 10 20 50 40 30 120 60 110 100 0-180 -120-60 0 60 120 180 C0-C180 C90-C270 Unit: cd 70 90 80
+86-760-88758975 Page 3 of 19 Pages Luminous Intensity Distribution Curve(cd/klm) 110 100 90 80 70 120 60 130 50 140 40 150 30 cd/klm C0-C180 C90-C270 160 20 170 10 180 104 208 313 417 522 0 170 10 160 20 150 30 140 40 130 50 120 60 110 70 η=100% 100 90 80
RC RW RCR 0 1 2 3 4 5 6 7 8 9 10 杭州创惠仪器有限公司 +86-760-88758975 Page 4 of 19 Pages Coefficients Of Utilization - Zonal Cavity Method 0.8 0.8 0.8 0.8 0.7 0.7 0.7 0.7 0.5 0.5 0.5 0.3 0.3 0.3 0.1 0.1 0.1 0 0.7 0.5 0.3 0.1 0.7 0.5 0.3 0.1 0.5 0.3 0.1 0.5 0.3 0.1 0.5 0.3 0.1 0 Spacing Criteria (0-180): 1.28 Spacing Criteria (90-270): 1.24 Spacing Criteria (Diagonal): 1.35 N 30 25 20 15 10 RF = 119 119 119 119 116 116 116 116 111 111 111 106 106 106 101 101 101 99 111 107 103 100 108 104 101 98 100 97 95 96 94 92 92 91 89 87 102 95 89 84 99 93 87 83 89 85 81 86 82 79 83 80 77 75 94 84 77 71 91 83 76 71 80 74 69 77 72 68 74 70 67 65 86 75 67 61 84 74 66 61 71 65 60 69 64 59 67 62 58 56 79 68 59 53 77 66 59 53 64 58 52 62 56 52 60 55 51 49 74 61 53 47 72 60 52 47 58 51 46 57 50 46 55 50 45 43 68 56 47 41 67 55 47 41 53 46 41 52 45 41 50 45 40 38 64 51 43 37 62 50 42 37 49 42 37 47 41 36 46 41 36 34 59 47 39 33 58 46 39 33 45 38 33 44 37 33 43 37 33 31 56 43 35 30 54 43 35 30 42 35 30 41 34 30 40 34 30 28 Curves of Luminaires vs Lighting Area H=2 8 7 6 Luminous Flux 5000 lm 5 Maintain Factor 0.70 4 Suspend Length 0.00m Work Height 0.80m 3 Average Lux 100 lx Reflectivity(%) Line Type Ceil Wall Floor 70 50 30 2 10 2 2 3 4 5 6 7 8 910 3 2 3 4 5 6 7 8 910 4 A(sq.m) H=10 H=12 H=7 H=5 H=3
Vertical(Deg) 80 60 40 20 0-20 -40-60 -80 1098 1831 732 1465 366 3661 杭州创惠仪器有限公司 +86-760-88758975 Page 5 of 19 Pages Isocandela (rectangle) 5492-80 -60-40 -20 0 20 40 60 80 Horizontal(Deg) Imax (100%): 7323 cd ( 5%): 366 cd ( 10%): 732 cd ( 15%): 1098 cd ( 20%): 1465 cd ( 25%): 1831 cd ( 50%): 3661 cd ( 75%): 5492 cd (100%): 7323 cd
Horizontal(m) 5 4 3 2 1 0 1 2 3 4 37 44 51 杭州创惠仪器有限公司 +86-760-88758975 Page 6 of 19 Pages 58 66 IsoLux Plot 5 5 4 3 2 1 0 1 2 3 4 5 Vertical(m) Mounting Height: 10.0m Max Lux(100%): 73.0 lx ( 50%): 36.5 lx ( 60%): 43.8 lx ( 70%): 51.1 lx ( 80%): 58.4 lx ( 90%): 65.7 lx (100%): 73.0 lx
Gamma 85 75 65 55 杭州创惠仪器有限公司 +86-760-88758975 Page 7 of 19 Pages Lum Limit Curve Dazzle Quality Illuminance (lx) 1.15 A 2000 1000 500 <=300 1.50 B 2000 1000 500 <=300 1.85 C 2000 1000 500 <=300 2.20 D 2000 1000 500 <=300 2.55 E 2000 1000 500 <=300 L(cd/sq.m) G45 G50 G55 G60 G65 G70 G75 G80 G85 C0 C90 C180 C270 a b c d e f g h a b c d e f g h 45 6 7 8 9 1000 2 3 4 5 6 7 8 9 10000 2 3 4 C90 C270 L(cd/sq.m) Gamma 85 75 65 55 a b c d e f g h 45 6 7 8 9 1000 2 3 4 5 6 7 8 9 10000 2 3 4 C0 C180 L(cd/sq.m) 4454 3690 2982 2269 1603 964 404 52 13 4873 4359 3418 2304 1295 413 44 23 9 4567 3813 3110 2389 1735 1099 525 105 22 4536 3980 3039 1969 943 151 34 18 7 8 6 4 a/hs 3 2 8 6 4 a/hs 3 2
Dh Dv 杭州创惠仪器有限公司 +86-760-88758975 Page 8 of 19 Pages Illuminance at a Distance Dist(m) Enadir(lx) Dh/Dv_B(m) S_B(sq.m) Eav_B(lx) 1.0 7298.70 2.44/2.66 5.2 1425.10 2.0 1824.68 4.89/5.33 20.8 356.28 3.0 810.97 7.33/7.99 46.9 158.34 4.0 456.17 9.78/10.65 83.3 89.07 5.0 291.95 12.22/13.31 13 57.00 6.0 202.74 14.67/15.98 187.4 39.59 7.0 148.95 17.11/18.64 255.1 29.08 8.0 114.04 19.55/21.30 333.2 22.27 10.0 72.99 24.44/26.63 520.6 14.25 12.0 50.69 29.33/31.95 749.7 9.90 Beam Angle(B): H101.4 V106.2 Field Angle(F): H145.0 V134.4
Vertical Height(m) 1 2 3 4 5 6 7 8 9 10 4379 3649 杭州创惠仪器有限公司 +86-760-88758975 Page 9 of 19 Pages Vertical IsoLux Plot 11 0 1 2 3 4 5 6 7 8 9 10 Horizontal distance(m) Lowest(m): 1.0m Highest(m): 11.0m Max Lux: 7298.7 lx ( 50%):3649.4 lx ( 60%):4379.2 lx ( 70%):5109.1 lx ( 80%):5839.0 lx ( 90%):6568.8 lx (100%):7298.7 lx
+86-760-88758975 Page 10 of 19 Pages The Average Illuminance Effective Figure Flux Out: 13007.11lm 1.0m 2772.03/ 7298.70lx 2.44m / 4.69sq.m 2.0m 693.01/ 1824.68lx 4.89m / 18.77sq.m 3.0m 308.00/ 810.97lx 7.33m / 42.23sq.m 4.0m 173.25/ 456.17lx 9.78m / 75.08sq.m 5.0m 110.88/ 291.95lx 12.22m / 117.31sq.m 6.0m 77.00/ 202.74lx 14.67m / 168.92sq.m 7.0m 56.57/ 148.95lx 17.11m / 229.92sq.m 8.0m 43.31/ 114.04lx 19.55m / 300.31sq.m 10.0m 27.72/ 72.99lx 24.44m / 469.23sq.m 12.0m 19.25/ 50.69lx 29.33m / 675.69sq.m Height Avg./Nadir. E Beam Angle:101.4 Diameter / Area
Reflectance: Ceiling (cavity) Wall Reference plane Room dimensions X=2H X=4H X=8H X=12H Y=2H 3H 4H 6H 8H 12H Y=2H 3H 4H 6H 8H 12H Y=4H 6H 8H 12H Y=4H 6H 8H 0.7 0.5 杭州创惠仪器有限公司 +86-760-88758975 Page 11 of 19 Pages 0.7 0.3 UGR Table 0.5 0.5 0.5 0.3 Viewed crosswise 0.3 0.3 0.7 0.5 0.7 0.3 0.5 0.5 0.5 0.3 Viewed endwise Variations with the observer position at spacings: S=1.0H -1.$/-1.$ -1.$/-1.$ S=1.5H -1.$/-1.$ -1.$/-1.$ S=2.0H -1.$/-1.$ -1.$/-1.$ Calculate in accordance with CIE Pub.117. The table is revised with 17519lm (8log(F/F0) = 9.9). 0.3 0.3
+86-760-88758975 Page 12 of 19 Pages Utilisation Factor Table(Floor cavity) Utilisation Factors UF(F) Room Reflectance Ceiling Wall Floor 0.70 0.50 0 0.30 0 0.50 0.50 0 0.30 0 0.30 0.50 0 0.30 0 0.00 0.00 0.00 Rating:203W Photometrically tested without ceiling board. Multiply UF values by service correction factors Room Index(RI) SHR NOM = 1.25 0.75 1.00 1.25 1.50 2.00 2.50 3.00 4.00 5.00 0.62 0.73 0.80 0.86 0.92 0.97 1.00 1.04 1.06 0.55 0.66 0.74 0.80 0.87 0.92 0.96 1.00 1.03 0.50 0.61 0.69 0.75 0.83 0.88 0.92 0.97 1.01 0.61 0.71 0.78 0.83 0.89 0.93 0.96 1.00 1.02 0.54 0.65 0.72 0.78 0.85 0.89 0.93 0.97 0.99 0.49 0.60 0.68 0.74 0.81 0.86 0.90 0.94 0.97 0.59 0.69 0.76 0.80 0.86 0.90 0.93 0.96 0.98 0.53 0.64 0.71 0.76 0.83 0.87 0.90 0.94 0.96 0.49 0.60 0.67 0.72 0.80 0.84 0.87 0.92 0.94 0.47 0.57 0.64 0.69 0.76 0.80 0.83 0.87 0.89 Calculate in accordance with CIBSE Technical Memorandum NO.5 1980
Utilisation Factors UF(W) Room Reflectance Ceiling Wall Floor 0.70 0.50 0 0.30 0 0.50 0.50 0 0.30 0 0.30 0.50 0 0.30 0 0.00 0.00 0.00 杭州创惠仪器有限公司 +86-760-88758975 Page 13 of 19 Pages Utilisation Factor Table(Wall) Rating:203W Photometrically tested without ceiling board. Multiply UF values by service correction factors Room Index(RI) SHR NOM = 1.25 0.75 1.00 1.25 1.50 2.00 2.50 3.00 4.00 5.00 0.91 0.73 0.61 0.52 0.40 0.33 8 1 0.17 0.76 0.62 0.53 0.46 0.37 0.30 6 0 0.16 0.65 0.54 0.47 0.41 0.33 8 4 0.19 0.16 0.87 0.70 0.58 0.49 0.38 0.35 6 0 0.16 0.74 0.60 0.51 0.44 0.35 9 5 0.19 0.16 0.64 0.53 0.46 0.40 0.32 7 3 0.18 0.15 0.85 0.67 0.55 0.47 0.36 0.30 5 0.19 0.15 0.72 0.59 0.49 0.43 0.34 8 3 0.18 0.15 0.63 0.52 0.45 0.39 0.31 6 2 0.17 0.14 0.52 0.42 0.35 0.30 3 0.19 0.16 0.12 0.10 Calculate in accordance with CIBSE Technical Memorandum NO.5 1980
+86-760-88758975 Page 14 of 19 Pages Utilisation Factor Table(Ceiling cavity) Utilisation Factors UF(C) Room Reflectance Ceiling Wall Floor 0.70 0.50 0 0.30 0 0.50 0.50 0 0.30 0 0.30 0.50 0 0.30 0 0.00 0.00 0.00 Rating:203W Photometrically tested without ceiling board. Multiply UF values by service correction factors Room Index(RI) SHR NOM = 1.25 0.75 1.00 1.25 1.50 2.00 2.50 3.00 4.00 5.00 0.16 0.17 0.18 0.19 0 0 1 2 2 0.10 0.12 0.13 0.14 0.16 0.17 0.18 0.19 0 0.06 0.07 0.09 0.10 0.12 0.14 0.15 0.17 0.18 0.16 0.17 0.18 0.18 0.19 0 0 1 1 0.10 0.11 0.13 0.14 0.15 0.16 0.17 0.18 0.19 0.06 0.07 0.09 0.10 0.12 0.14 0.15 0.16 0.17 0.15 0.16 0.17 0.18 0.18 0.19 0.19 0 0 0.10 0.11 0.12 0.13 0.15 0.16 0.17 0.18 0.19 0.06 0.07 0.09 0.10 0.12 0.13 0.14 0.16 0.17 0.01 0.01 0.01 0.01 0.01 0.01 0.01 0.01 0.01 Calculate in accordance with CIBSE Technical Memorandum NO.5 1980
+86-760-88758975 Page 15 of 19 Pages Zonal Lumen Gamma Imean Zonal Flux Sum Zonal Flux Rel Zonal FluxSum Rel Zonal Flux [ ] [cd] [lm] [lm] [%] [%] 0.0-1.0 7199.5 6.9 6.9 0.04 0.04 1.0-2.0 7198.4 20.7 27.6 0.12 0.16 2.0-3.0 7194.5 34.4 62.0 0 0.35 3.0-4.0 7186.9 48.1 110.1 7 0.63 4.0-5.0 7176.4 61.7 171.8 0.35 0.98 5.0-6.0 7164.0 75.3 247.1 0.43 1.41 6.0-7.0 7149.6 88.8 335.9 0.51 1.92 7.0-8.0 7133.5 102.1 438.0 0.58 2.50 8.0-9.0 7115.3 115.3 553.3 0.66 3.16 9.0-10.0 7096.1 128.4 681.7 0.73 3.89 10.0-11.0 7074.5 141.4 823.1 0.81 4.70 11.0-12.0 7048.3 154.1 977.2 0.88 5.58 12.0-13.0 7018.4 166.6 1143.8 0.95 6.53 13.0-14.0 6986.9 178.9 1322.7 1.02 7.55 14.0-15.0 6954.7 191.0 1513.6 1.09 8.64 15.0-16.0 6921.1 202.8 1716.4 1.16 9.80 16.0-17.0 6883.6 214.4 1930.8 1.22 11.02 17.0-18.0 6842.0 225.6 2156.5 1.29 12.31 18.0-19.0 6799.0 236.6 2393.0 1.35 13.66 19.0-20.0 6756.7 247.3 2640.4 1.41 15.07 20.0-21.0 6714.7 257.9 2898.2 1.47 16.54 21.0-22.0 6670.7 268.1 3166.3 1.53 18.07 22.0-23.0 6624.4 278.0 3444.3 1.59 19.66 23.0-24.0 6575.4 287.5 3731.9 1.64 21.30 24.0-25.0 6522.3 296.6 4028.5 1.69 22.99 25.0-26.0 6466.7 305.3 4333.8 1.74 24.74 26.0-27.0 6410.1 313.6 4647.4 1.79 26.53 27.0-28.0 6350.3 321.6 4969.0 1.84 28.36 28.0-29.0 6283.2 328.8 5297.7 1.88 34 29.0-30.0 6210.4 335.4 5633.1 1.91 32.15 30.0-31.0 6135.1 341.5 5974.6 1.95 34.10 31.0-32.0 6057.6 347.1 6321.7 1.98 36.08 32.0-33.0 5980.0 352.3 6674.0 2.01 38.10 33.0-34.0 5897.0 356.9 7030.9 2.04 40.13 34.0-35.0 5807.6 360.7 7391.6 2.06 42.19 35.0-36.0 5716.5 364.0 7755.7 2.08 44.27
+86-760-88758975 Page 16 of 19 Pages Zonal Lumen (Continue 1) Gamma Imean Zonal Flux Sum Zonal Flux Rel Zonal FluxSum Rel Zonal Flux [ ] [cd] [lm] [lm] [%] [%] 36.0-37.0 5623.9 366.8 8122.5 2.09 46.36 37.0-38.0 5523.6 368.7 8491.3 2.10 48.47 38.0-39.0 5409.5 369.3 8860.5 2.11 50.58 39.0-40.0 5287.8 368.8 9229.4 2.11 52.68 40.0-41.0 5168.0 368.1 9597.4 2.10 54.78 41.0-42.0 5051.8 367.1 9964.5 2.10 56.88 42.0-43.0 4932.0 365.4 10329.9 2.09 58.96 43.0-44.0 4803.3 362.6 10692.5 2.07 61.03 44.0-45.0 4671.0 359.0 11051.5 2.05 63.08 45.0-46.0 4535.8 354.8 11406.3 2.03 65.11 46.0-47.0 4400.7 350.1 11756.3 2.00 67.11 47.0-48.0 4273.1 345.5 12101.8 1.97 69.08 48.0-49.0 4139.1 340.0 12441.8 1.94 71.02 49.0-50.0 4000.4 333.6 12775.4 1.90 72.92 50.0-51.0 3868.2 327.3 13102.7 1.87 74.79 51.0-52.0 3729.2 320.0 13422.7 1.83 76.62 52.0-53.0 3570.3 310.6 13733.3 1.77 78.39 53.0-54.0 3402.2 299.9 14033.2 1.71 80.10 54.0-55.0 3251.4 290.3 14323.5 1.66 81.76 55.0-56.0 3100.4 28 14603.7 1.60 83.36 56.0-57.0 2936.3 268.5 14872.2 1.53 84.89 57.0-58.0 2786.0 257.7 15129.9 1.47 86.36 58.0-59.0 2633.3 246.2 15376.1 1.41 87.77 59.0-60.0 2466.2 233.0 15609.1 1.33 89.10 60.0-61.0 2302.3 219.7 15828.9 1.25 90.35 61.0-62.0 2125.0 204.8 16033.7 1.17 91.52 62.0-63.0 1929.5 187.7 16221.4 1.07 92.59 63.0-64.0 1757.3 172.5 16393.8 0.98 93.58 64.0-65.0 1581.3 156.5 16550.3 0.89 94.47 65.0-66.0 1404.5 140.1 16690.5 0.80 95.27 66.0-67.0 1242.3 124.9 16815.4 0.71 95.98 67.0-68.0 1072.2 108.6 16924.0 0.62 96.60 68.0-69.0 917.5 93.6 17017.7 0.53 97.14 69.0-70.0 775.7 79.7 17097.3 0.45 97.59 70.0-71.0 636.6 65.8 17163.1 0.38 97.97 71.0-72.0 507.4 52.8 17215.9 0.30 98.27
+86-760-88758975 Page 17 of 19 Pages Zonal Lumen (Continue 2) Gamma Imean Zonal Flux Sum Zonal Flux Rel Zonal FluxSum Rel Zonal Flux [ ] [cd] [lm] [lm] [%] [%] 72.0-73.0 406.2 42.5 17258.4 4 98.51 73.0-74.0 325.0 34.2 17292.6 0 98.71 74.0-75.0 248.4 26.3 17318.8 0.15 98.86 75.0-76.0 18 19.1 17337.9 0.11 98.97 76.0-77.0 126.2 13.5 17351.4 0.08 99.04 77.0-78.0 89.3 9.6 17361.0 0.05 99.10 78.0-79.0 63.9 6.9 17367.8 0.04 99.14 79.0-80.0 45.1 4.9 17372.7 0.03 99.16 80.0-81.0 32.5 3.5 17376.2 0.02 99.18 81.0-82.0 25.1 2.7 17378.9 0.02 99.20 82.0-83.0 20.4 2.2 17381.1 0.01 99.21 83.0-84.0 16.2 1.8 17382.9 0.01 99.22 84.0-85.0 12.5 1.4 17384.3 0.01 99.23 85.0-86.0 9.4 1.0 17385.3 0.01 99.24 86.0-87.0 6.0 0.7 17386.0 0.00 99.24 87.0-88.0 2.8 0.3 17386.3 0.00 99.24 88.0-89.0 0.7 0.1 17386.3 0.00 99.24 89.0-90.0 0.0 0.0 17386.3 0.00 99.24 90.0-91.0 0.0 0.0 17386.3 0.00 99.24 91.0-92.0 0.0 0.0 17386.3 0.00 99.24 92.0-93.0 0.3 0.0 17386.4 0.00 99.24 93.0-94.0 0.7 0.1 17386.4 0.00 99.24 94.0-95.0 1.0 0.1 17386.6 0.00 99.24 95.0-96.0 1.8 17386.8 0.00 99.24 96.0-97.0 2.3 17387.0 0.00 99.25 97.0-98.0 2.5 0.3 17387.3 0.00 99.25 98.0-99.0 3.0 0.3 17387.6 0.00 99.25 99.0-100.0 4.0 0.4 17388.0 0.00 99.25 100.0-101.0 4.7 0.5 17388.5 0.00 99.25 101.0-102.0 6.1 0.7 17389.2 0.00 99.26 102.0-103.0 7.4 0.8 17390.0 0.00 99.26 103.0-104.0 8.0 0.9 17390.8 0.00 99.27 104.0-105.0 8.6 0.9 17391.8 0.01 99.27 105.0-106.0 9.3 1.0 17392.7 0.01 99.28 106.0-107.0 10.0 1.1 17393.8 0.01 99.28 107.0-108.0 10.6 1.1 17394.9 0.01 99.29
+86-760-88758975 Page 18 of 19 Pages Zonal Lumen (Continue 3) Gamma Imean Zonal Flux Sum Zonal Flux Rel Zonal FluxSum Rel Zonal Flux [ ] [cd] [lm] [lm] [%] [%] 108.0-109.0 11.3 1.2 17396.1 0.01 99.30 109.0-110.0 11.9 1.2 17397.3 0.01 99.30 110.0-111.0 12.6 1.3 17398.6 0.01 99.31 111.0-112.0 13.4 1.4 17400.0 0.01 99.32 112.0-113.0 14.1 1.4 17401.4 0.01 99.33 113.0-114.0 14.7 1.5 17402.9 0.01 99.34 114.0-115.0 15.4 1.5 17404.4 0.01 99.34 115.0-116.0 16.1 1.6 17406.0 0.01 99.35 116.0-117.0 16.8 1.7 17407.6 0.01 99.36 117.0-118.0 17.5 1.7 17409.4 0.01 99.37 118.0-119.0 18.3 1.8 17411.1 0.01 99.38 119.0-120.0 19.1 1.8 17412.9 0.01 99.39 120.0-121.0 19.9 1.9 17414.8 0.01 99.40 121.0-122.0 20.6 1.9 17416.7 0.01 99.42 122.0-123.0 21.3 2.0 17418.7 0.01 99.43 123.0-124.0 22.0 2.0 17420.7 0.01 99.44 124.0-125.0 22.8 2.1 17422.8 0.01 99.45 125.0-126.0 23.5 2.1 17424.9 0.01 99.46 126.0-127.0 24.3 2.1 17427.0 0.01 99.47 127.0-128.0 25.0 2.2 17429.2 0.01 99.49 128.0-129.0 25.8 2.2 17431.4 0.01 99.50 129.0-130.0 26.5 2.2 17433.7 0.01 99.51 130.0-131.0 27.2 2.3 17435.9 0.01 99.52 131.0-132.0 27.9 2.3 17438.2 0.01 99.54 132.0-133.0 28.7 2.3 17440.5 0.01 99.55 133.0-134.0 29.5 2.3 17442.9 0.01 99.56 134.0-135.0 3 2.4 17445.2 0.01 99.58 135.0-136.0 30.9 2.4 17447.6 0.01 99.59 136.0-137.0 31.6 2.4 17450.0 0.01 99.61 137.0-138.0 32.3 2.4 17452.4 0.01 99.62 138.0-139.0 32.9 2.4 17454.8 0.01 99.63 139.0-140.0 33.7 2.4 17457.2 0.01 99.65 140.0-141.0 34.4 2.4 17459.6 0.01 99.66 141.0-142.0 35.0 2.4 17462.0 0.01 99.67 142.0-143.0 35.7 2.4 17464.3 0.01 99.69 143.0-144.0 36.4 2.4 17466.7 0.01 99.70
+86-760-88758975 Page 19 of 19 Pages Zonal Lumen (Continue 4) Gamma Imean Zonal Flux Sum Zonal Flux Rel Zonal FluxSum Rel Zonal Flux [ ] [cd] [lm] [lm] [%] [%] 144.0-145.0 37.1 2.4 17469.1 0.01 99.71 145.0-146.0 37.7 2.3 17471.4 0.01 99.73 146.0-147.0 38.3 2.3 17473.7 0.01 99.74 147.0-148.0 39.0 2.3 17476.0 0.01 99.75 148.0-149.0 39.5 2.3 17478.3 0.01 99.77 149.0-150.0 40.1 2.2 17480.5 0.01 99.78 150.0-151.0 40.8 2.2 17482.7 0.01 99.79 151.0-152.0 41.3 2.2 17484.9 0.01 99.80 152.0-153.0 41.9 2.1 17487.0 0.01 99.82 153.0-154.0 42.5 2.1 17489.1 0.01 99.83 154.0-155.0 43.1 2.0 17491.1 0.01 99.84 155.0-156.0 43.8 2.0 17493.1 0.01 99.85 156.0-157.0 44.5 1.9 17495.1 0.01 99.86 157.0-158.0 45.1 1.9 17497.0 0.01 99.87 158.0-159.0 45.6 1.8 17498.8 0.01 99.88 159.0-160.0 46.0 1.8 17500.6 0.01 99.89 160.0-161.0 46.5 1.7 17502.3 0.01 99.90 161.0-162.0 47.0 1.6 17503.9 0.01 99.91 162.0-163.0 47.5 1.6 17505.5 0.01 99.92 163.0-164.0 48.0 1.5 17507.0 0.01 99.93 164.0-165.0 48.6 1.4 17508.4 0.01 99.94 165.0-166.0 49.0 1.3 17509.7 0.01 99.95 166.0-167.0 49.5 1.3 17511.0 0.01 99.95 167.0-168.0 49.9 1.2 17512.2 0.01 99.96 168.0-169.0 50.3 1.1 17513.3 0.01 99.97 169.0-170.0 50.5 1.0 17514.3 0.01 99.97 170.0-171.0 50.8 0.9 17515.2 0.01 99.98 171.0-172.0 51.0 0.8 17516.0 0.00 99.98 172.0-173.0 51.2 0.7 17516.8 0.00 99.99 173.0-174.0 51.3 0.6 17517.4 0.00 99.99 174.0-175.0 51.5 0.5 17517.9 0.00 99.99 175.0-176.0 51.5 0.4 17518.4 0.00 100.00 176.0-177.0 51.7 0.3 17518.7 0.00 100.00 177.0-178.0 51.8 17519.0 0.00 100.00 178.0-179.0 51.8 0.1 17519.1 0.00 100.00 179.0-180.0 51.9 0.0 17519.2 0.00 100.00