Reliability Laboratory Page: 1 of 6 Date: March 5, 2008 KORENIX TECHNOLOGY., CO. FL 9, NO. 100-1, MIN-CHUAN RD. SHING TIEN CITY, TAIPEI, TAIWAN The following merchandise was submitted and identified by the vendor as: Product Description: 1. Industrial Communication Computer 2. JetNet PoE Switch 3. Industrial Fast Ethernet to Fiber Media Converter Style/ Item No.: 1. JetBox8210/ No.1, No.2; JetBox9310/ No.1; JetBox9300/ No.1; JetBox8100/ No.1 2. JetNet 5010G/ No.1; JetNet 4706/ No.1 3. JetCon 1301-s/ No.1 Quantity: Total 8 sets Testing Period: Jan. 30, 2008 to Jan. 31, 2008 We have tested the submitted sample(s) as requested and the following results were obtained: Test Required: (According to client s test specification, please see following sheets in detail.) 1. Vibration Test Test Results: PLEASE SEE ATTACHED SHEETS *HC20093/2008, dated February 26, 2008, is hereby canceled and replaced by HC20093A/2008. Terence Hsieh Asst. Manager
Page: 2 of 6 1. Vibration Test: Test Equipment: Name Brand Model Serial No. Vibration test System UNHOLTZ-DICKIE SAI60-H560BAC/2/ST 474 Controller Dactron LASER 7110357 Control Accelerometer PCB 353B34 121615 Lab Environmental Conditions: Ambient temperature: 25±3 Relative humidity: 55±20%RH Test Method/ Specification: Test method: Reference to IEC 60068-2-6:1996 Sample condition: Operating Wave form: Sinusoidal Frequency: 10~150 Hz Amplitude(D p-p ): 0.7 mm (10~60 Hz) Acceleration 50 m/s 2 (60~150 Hz) Sweep rate: 1 octave/ minute Direction: X, Y, Z axes (see photo 8~13) Test duration: 150 minutes/ axis Examine the appearance of specimen(s) by visual check and perform functional check after this test. Functional check: Connect the specimen with PC via RJ-45 port and examine the Network Connecting Function of specimen could be work normally or not.
Page: 3 of 6 Specimen: Style/ Item No.: Quantity: 1. JetBox8210/ No.1, No.2; JetBox9310/ No.1; JetBox9300/ No.1; JetBox8100/ No.1 2. JetNet 5010G/ No.1; JetNet 4706/ No.1 3. JetCon 1301-s/ No.1 8 sets Test Result: Style/ Item No. Check Item Appearance check (visual check) Functional Check JetBox8210/ No.1 No visible damage Normal JetBox8210/ No.2 No visible damage Normal JetBox9310/ No.1 No visible damage Normal JetBox9300/ No.1 No visible damage Normal JetBox8100/ No.1 No visible damage Normal JetNet 5010G/ No.1 No visible damage Normal JetNet 4706/ No.1 No visible damage Normal JetCon 1301-s/ No.1 No visible damage Normal
Page: 4 of 6 Test Photos: 1. Appearance of specimen (JetBox8100) 2. Appearance of specimen (JetBox9310) 3. Appearance of specimen (JetBox9300) 4. Appearance of specimen (JetBox8210) 5. Appearance of specimen (JetNet 4706) 6. Appearance of specimen (JetNet 5010G)
Page: 5 of 6 Test Photos--Continued: 7. Appearance of specimen (JetCon 1301-s) 8. Vibration test--x axis 9. Vibration test--x axis 10. Vibration test--y axis 11. Vibration test--y axis
Page: 6 of 6 Test Photos--Continued: 12. Vibration test--z axis 13. Vibration test--z axis 14. Functional check The End of Test Report