Siemens AG 2007 SITRANS F flowmeters Overview MASS 2100 DI 1.5 is suitable for low flow measurement applications of a variety of liquids and gases. The sensor offers superior performance in terms of flow accuracy, turn-down range and density accuracy. The ease of installation through a "plug & play" mechanical and electrical interface ensures optimum performance and operation. The sensor delivers true multiparameter measurements i.e.: Mass flow, volume flow, density, temperature and fraction. Benefits High accuracy better than 0.1% of mass flow rate Large dynamic turn down range better than 500:1, from 65 kg/h to a few g/h Densitometer performance available through a density accuracy better than 0.001 g/cm 3 with a repeatability better than 0,0002 g/cm 3 Single continuous tube design, with no internal welds, reductions or flow splitters offers optimal hygiene, safety and CIP cleanability for food & beverage and pharmaceutical applications Market s biggest wall thickness, ensuring optimal lifetime and corrosion resistance and high pressure durability Balanced pipe design with little mechanical energy-loss, ensures optimal performance and stability under non ideal and unstable process conditions (pressure, temperature, densitychanges etc.) -wire Pt1000 temperature measurement ensures optimum accuracy on mass flow, density and fraction flow Multi-plug electrical connector & SENSORPROM enables true "plug & play". Installation and commissioning in less than 10 min. Intrinsically safe EEx ia design as standard Sensor pipe available in high quality AISI 316L stainless steel 1.35 or Hastelloy C 22 2.602 offering optimum corrosion resistance Dual-drive pick-up and driver construction facilitate ultra lowweight pipe construction giving the markets smallest and most stable zero point Rugged and space saving sensor design in stainless steel matching all environments High pressure program as standard The sensor calibration factor is also valid for gas measurement Application In many industries such as the food & beverage or pharamceutical industry, accurate recipe control means everything. The MASS 2100 DI 1.5 has demonstrated superiour performance in numerous applications and field trails relating to accuracy and turn down ratio. It is today the prefeered meter for research and development and mini-plant applications for liquid or gas measurement, where measuring small quantities is important. The main applications for the MASS 2100 DI 1.5 sensor can be found in: Chemical industry Liquid and gas measurement within Miniplant and R&D, dosing of additives and catalysts Cosmetic industry Dosing of essence & fragrances Pharmaceutical industry High speed dosing and coating of pills, filling of ampuls/injectors Food & beverage industry Dosing of flavourings, colours and additives, density measurement, in-line Measurement of liquid or gaseous CO 2 Automotive industry Fuel injection nozzle & pump testing, filling of AC units, engine consumption, paint robots, ABS testbeds Design The MASS 2100 sensor consists of a single bent tube in a double omega pipe configuration, welded directly to the process connectors at each end. The sensor is available in 2 material configurations, AISI 316L or Hastelloy C22 with ¼ NPT or ¼ ISO process connections. The enclosure is made in stainless steel AISI 316L 1.0 with a grade of encapsulation of IP65/NEMA. The sensor is available in either a standard version with a maximum liquid temperature of 125 C (257 F) or a high temperature version, with raised electrical connector for 180 C (356 F). The sensor can be installed in horizontal or vertical position. The enclosed single quick release clamp fitting which, along with its compact design and single multi-plug electrical connector, will keep installation costs and time to a minimum as shown below. Siemens FI 01 2008 /139
SITRANS F flowmeters Siemens AG 2007 Function The measuring principle is based on coriolis force of movement, see System information MASSFLO coriolis mass flowmeters. Technical specifications Versions Inside pipe diameter (sensor consists DI 1.5 (1/16 ) 1.5 mm (0.06 ) Integration of one continuous pipe) Pipe wall thickness 0.25 mm (0.010 ) The sensor can be connected to all MASS 6000 transmitters for remote installation only. Mass flow measuring range Density 0... 65 kg/h (0... 13 lb/h) 0... 2.9 g/cm 3 (0... 0.10 lb/inch 3 ) Fraction e.g. 0... 100 Brix All sensors are delivered with a SENSORPROM containing all information about calibration data, identity and factory pre-programming Temperature of transmitter settings Installation guidelines MASS 2100 DI 1.5 (1/16 ) Standard High temperature version -50... +125 C (-58... +257 F) -50... +180 C (-58... +356 F) Liquid pressure measuring pipe 1) Installation of MASS 2100 sensor Stainless steel 230 bar (3336 psi) at 20 C The optimal installation is horizontal. (68 F) If vertical mounting is necessary, upward flow is recommended to facilitate the removal of air bubbles. To remove the (68 F) Hastelloy C-22 365 bar (529 psi) at 20 C air from the sensor the flow speed in the sensor must be at Materials least 1 m/s. If there are solid particles in the liquid, especially in connection with low flow, it is recommended that the sensor be Measuring pipe and connection 1.35 (AISI 316L) (stainless steel) mounted horizontally with inlet flange uppermost so that particles 2.602 (Hastelloy C-22) are more easily flushed out. To ensure that the sensor Enclosure and enclosure IP66/NEMA and 1.0 does not become partially empty, there must be sufficient material 2) (AISI 316L) (stainless steel) counter-pressure on the unit min. 0.1 to 0.2 bar (1.5 to Connection thread 2.9 psi). ISO 228/1 G¼ male Mount the sensor on a vibration-free wall or steel frame. ANSI/ASME B1.20.1 ¼ NPT male Locate the sensor low in the system in order to avoid an underpressure in the sensor separating air/gas in the liquid. sor 5 x 2 x 0.35 mm 2 twisted and Cable connection Multiple plug connection to sen- Ensure that the sensor is not emptied of liquid (during normal operation) otherwise incorrect measurement will occur. Horizontal Ex-version screened in pairs, ext. Ø 12 mm EEx ia IIC T3-T6, DEMKO 03 ATEX 135252X Weight approx. 2.6 kg (5.73 lb) 1) According to DIN 213, DIN 1757 2) Housing is not rated for pressure containment. For accuracy specifications see System information MASSFLO. Pressure drop Liquid and gas application Vertical p [bar] 100 Viscosity [cst] 1000 500 200 5 100 10 50 20 10 1.0 1 Liquid application (left), gas application (right) 0.1 0.01 0.1 1 10 70 Mass flow [kg/h] MASS 2100 DI 1.5 (1/16 ), pressure drop for density = 1000 kg/m 3 /10 Siemens FI 01 2008
Siemens AG 2007 SITRANS F flowmeters Selection and Ordering data 1) Not possible to order DI 1.5 sensor with heat jacket Order-No. Order code Flow sensors MASSFLO 2100 DI 1.5 (1/16 ) sensor, without heating jacket 1) F) 7ME100-7777 7-7 A 7 7 7 7 7 Diameter Stainless steel 1.35/316L DI 1.5, max. 125 C (257 F) 1 A DI 1.5, max. 180 C (356 F) 1 B 2.602/Hastelloy C22 DI 1.5, max. 125 C (257 F) 2 A DI 1.5, max. 180 C (356 F) 2 B Pressure PN 100 D PN 230 (316L) L PN 365 (C-22) P Process connection/flange Pipe thread G ¼ male 1 0 ¼ NPT male 1 1 Configuration Standard 1 Density 2 Brix/Plato 3 Fraction (specification required) 9 N 0 Y Cable No cable A 5 m (16 ft) cable B 10 m (32 ft) cable C 25 m (82 ft) cable D 50 m (16 ft) cable E 75 m (26 ft) cable F 150 m (92 ft) cable G Calibration Standard calibration 3 flow x 2 points 1 Standard calibration matched pair 3 flow x 2 2 points Accredited calibration matched pair 5 flow x 3 2 points (DANAK) Extended calibration customer specified 8 select Y60, Y61, Y62 or Y63 (see additional information) Please also see www.siemens.com/sitransfordering for practical examples of ordering Selection and Ordering data Additional information Please add -Z to Order No. and specify Order code(s) and plain text. Pressure testing certificate PED: 97/23/EC Material certificate EN 1020-3.1B Welding certificate NDT-Penetrant: ISO 352 Factory certificate according to EN 1020 2.2 Factory certificate according to EN 1020 2.1 Tag name plate, stainless steel Tag name plate, plastic Customer specific transmitter setup Customer specified, matched pair (5x2) Customer specified calibration (5x2) Customer specified, matched pair (10x1) Customer specified calibration (10x1) Special version Order code C11 C12 C13 C1 C15 Y17 Y18 Y20 Y60 Y61 Y62 Y63 Y99 Spare parts Description Order No. F) Multiple plug for cable mounting FDK-083H5056 Description Length Order No. Cable with multiple plug 5 m (16. ft) FDK-083H3015 Standard blue cable between 10 m (32.8 ft) FDK-083H3016 MASS 6000 and MASS 2100, 5 x 2 x 0,3 mm 2 twisted and 25 m (82 ft) FDK-083H3017 screened in pairs. Temperature range -20 C... +110 C 50 m (16 ft) FDK-083H3018 (- F... +230 F) 75 m (26 ft) FDK-083H305 150 m (92 ft) FDK-083H3055 Description Order No. F) 2 kb SENSORPROM unit FDK-083H10 (Sensor Serial No. and Order No. must be specified by ordering) F) All products on this page subject to export regulations AL: 9I999, ECCN: N. Siemens FI 01 2008 /11
SITRANS F flowmeters Siemens AG 2007 Dimensional drawings MASS 2100 DI 1.5 (1/16 ) Dimensions in mm (inch) MASS 2100 DI 1.5 High temperature version to 180 C (356 F) Dimensions in mm (inch) /12 Siemens FI 01 2008
DELLSONICS 北京迪妙声科技有限公司 BEJING DELLSONICS SCIENCE & TECHNOLOGY LTD. 公司简介 北京迪妙声科技有限公司 ( 原名北京妙声力科技有限公司 ), 位于北京市海淀区中关村南大街, 是与西门子公司德国总部正式签约的西门子过程仪表及分析仪器核心合作伙伴, 也是西门子北方区域规模最大 实力最强的优秀代理商 公司主营 : 一 西门子 - 妙声力 (Milltronics) 系列物位产品 : 超声波物位计 超声波液位差计 超声波泥水界面计 超声波明渠流量计 雷达物位计 射频导纳物位计 射频导纳油水界面计 ; 射频导纳物位开关 音叉式物位开关 阻旋式物位开关 ; 皮带称 固体质量流量计 冲板流量计等 二 西门子过程仪表产品 : 电磁流量计 质量流量计 超声波流量计 温度变送器 压力变送器 阀门定位器 气体分析仪等 三 德国 UWT 公司的阻旋式料位开关 音叉式料位开关 重锤式料位计等产品 四 自行研发生产超声波液位计 温度变送器 压力变送器 数显表及油田专用仪器等产品 成立于 195 年的西门子 - 妙声力公司 (Milltronics) 是世界公认的超声波物位测量领域的领导者, 全球最大的超声波物位仪表生产厂家, 在超声波 雷达 电容技术领域拥有超过 60 项专利, 超声波产品的综合性能指标经美国 控制 杂志评比, 其综合性能名列全球第一! 作为西门子公司长期稳定的代理商, 我公司有着 10 余年产品的销售和服务经验, 无论从专业技术水平 现货及备件库存量 售后服务质量 仪表维护以及故障产品国内维修能力等方面, 都具备显著的优势 尤其是我公司一流的技术支持和高效率高品质的服务体系, 在业界具有很高的知名度 如果您需要相关的产品, 需要咨询技术问题, 需要值得信赖的合作伙伴, 敬请来电垂询! 商务部总机电话 :010-88579530/31/32/33,88579597,8857181,81968099( 小灵通 ) 传真 : 总机转 50 谢谢您的合作与支持! 地址 : 北京海淀区魏公村街 1 号韦伯豪家园 3-3-702 (100081) http://www.dellsonics.com 电话 :010-88579530/31/32/33,88579597,8857181 传真 : 总机转 50 E-mail:sales@dellsonics.com