Reliability Laboratory Page: 1 of 6 Date: September 5, 2008 WINMATE COMMUNICATION INC. 9 F, NO. 111-6, SHING-DE RD., SAN-CHUNG CITY, TAIPEI, TAIWAN, R.O.C. The following merchandise was submitted and identified by the vendor as: Product Description: Rugged Box PC Style/ Item No.: I330EAC-XXX/ No. 1 Quantity: Total 1 set Testing Period: Aug. 7, 2008 We have tested the submitted sample(s) as requested and the following results were obtained: Test Required: (According to client s test specification, please see following sheets in detail.) 1. Vibration Test Test Results: -PLEASE SEE ATTACHED SHEETS- Terence Hsieh Asst. Manager
Page: 2 of 6 1. Vibration Test: Test Equipment: Name Brand Model Serial No. Vibration Test System UNHOLTZ-DICKIE SAI60-H560BAC/2/ST 474 Controller Dactron LASER 7110357 Control Accelerometer PCB 353B34 121615 Triaxial ICP Accelerometer PCB 356A02 67433 Lab Environmental Conditions: Ambient temperature: 25±3 Relative humidity: 55±20%RH Test Method/ Specification: 1. Resonance Search: Test method: Reference to IEC 60945:2002, section 8.7 Sample condition: Unpackaged and Operating Wave form: Sinusoidal Frequency: 3~100 Hz Displacement(D p-p ) 2 mm +/-10% (3~13.2 Hz) Acceleration: 0.7 G (13.2~100 Hz) Sweep Rate: 0.5 octave/ minute Direction: X, Y, Z axes (See photo 7 ~ 12) Test duration: 1 sweep / axis
Page: 3 of 6 Test Method/ Specification--Continued: 2. Dwell Vibration test: Frequency: Frequency of major peaks where the amplification factor greater than 2 (if it appears) during Resonance Search in each direction. If no resonance frequency found, dwell at 30 Hz. Acceleration: Same condition as specified in resonance search. Dwell: 120 minutes/ peak Place the product on the vibration table in its normal operating orientation and configuration. The Product shall be no fixture to the vibration table such that the vibratory input is transmitted directly to the product. Operating the product during the test. Vibrate the product up the frequency range at a rate of 3 to 100 Hz. At the appropriate level in the table of test condition in each of three orthogonal axes. The EUT shall be subjected to sinusoidal vertical vibration at all frequencies between: 3 Hz to 5 Hz and up to 13.2 Hz with an excursion of ± 1 mm ± 10 % / above 13.2 Hz and up to 100 Hz with a constant maximum acceleration of 7 m/s 2. The frequency sweep rate shall be 0.5 octaves / min in order to allow the detection of resonances in any part of the EUT as mounted. Document the result during the test. The functional and electrical check is required, document the result after the check. Measuring accelerometer is attached on the designated position of specimen in each axis for Resonance search. (see photo 8, 10 and 12) Examine the appearance of specimen(s) by visual check and perform functional and performance check after this test. Functional check: Connect the specimen with rated power (24 V DC ) then examine whether the booting function of specimen could be work normally or not. (The extreme power supply voltage test shell be with a tolerance of +30% and -25%.) Performance check: Running Windows XP with stress software BCM Diagnostics Pro version 2.30. The requirement of the displacement check shall be met.
Page: 4 of 6 Specimen: Style/ Item No.: I330EAC-XXX/ No. 1 Quantity: Total 1 piece Test Result: 1. Resonance Search Result: Test Item Major Resonance Frequency Unit: Hz Style/ Item No. Direction X axis Y axis Z axis I330EAC-XXX/ No. 1 * * * Note:*No resonance frequency was found. 2. Examination of produce (Appearance check and functional check): Check Item Appearance check (Visual check) Style/ Item No. Initial Final Functional Check & Performance Check I330EAC-XXX/ No. 1 No visible damage No visible damage Normal
Page: 5 of 6 Test Photos: 1. Appearance of specimen 2. Appearance of specimen 3. Appearance of specimen 4. Appearance of specimen 5. Appearance of specimen 6. Appearance of specimen
Page: 6 of 6 Test Photos--Continued: 7. Vibration Test: X axis 8. Vibration Test: X axis 9. Vibration Test: Y axis 10. Vibration Test: Y axis 11. Vibration Test: Z axis 12. Vibration Test: Z axis The End of Test Report