+'0, &RPSOLDQFH 7HVW (TXLSPHQW 6WDQGDUG &RQW +'0, &RPSOLDQFH 7HVW,WHP $GGLWLRQDO 7HVWV ¾ +($& ± (OHFWULFDO &KDUDFWHULVWLFV 7HVWV ± &DEOH $VVHPEO\ 7HVWV ± &DSDELOLW\ 'LVFRYHU\ DQG &RQWURO ± 1HWZRUNLQJ ¾ +'&3 &RPSOLDQFH 7HVW 6SHF 9HUVLRQ ± 6RXUFH 7HVWV ± 6LQN 7HVWV ± &DEOH 7HVWV 3-16
3-17
Quick Fact Sheet Agilent Infiniium 9000 Series Oscilloscopes Engineered for broadest measurement capability Extend your scope capability with protocol analysis. The tracking marker/bar shows precise time alignment between protocol viewer and analog waveforms What makes the Infiniium 9000 Series the go-to scope for a complete range of test and debug challenges? Use responsive deep memory to see longer periods of time. Three instruments in one. Oscilloscope: Fast sample and update rates let you see a precise representation of your signal. Scope is packed with features and analysis capabilities. Logic analyzer: Fast, deep-memory digital channels show critical data values and timing relationships Protocol analyzer: World s fi rst scopebased protocol viewer with multi-tab viewing so you can quickly move between protocol and physical layers. Widest range of application-specific software for debug, analysis and compliance testing Sized to fit your environment with the largest display (15 ), a smaller depth (9 ) and lighter weight (26 lbs) than any other scope in its class. Integrated mixed-signal oscilloscope lets you trigger across time-correlated analog and digital channel combinations. Key specifications Bandwidth 600 MHz, 1 GHz, 2.5 GHz and 4 GHz models Channels 4-ch,and 4-ch + 16 digital channels models Sample rate 10 GSa/s (20 GSa/s on 2-ch) (600 MHz is 5 GSa/s on 4 ch and 10 GSa/s on 2 ch) Memory 10 Mpts standard (20 Gpts on 2-ch) Display 15 high-defi nition display with XGA resolution Triggering Edge, glitch, runt, timeout, pattern/ pulse range, state, pulse width line, window, setup and hold, video and serial Warranty Standard 1-year warranty
Quick Fact Sheet Order the mixed-signal oscilloscope (MSO) to add 16 digital timing channels to any scope Oscilloscope models Sample* rate Memory * depth Scope channels Model Bandwidth DSO9064A 600 MHz 5 GSa/s 10 Mpts 4 MSO9064A 600 MHz 5 GSa/s 10 Mpts 4 + 16 digital DSO9104A 1 GHz 10 GSa/s 10 Mpts 4 MSO9104A 1 GHz 10 GSa/s 10 Mpts 4 + 16 digital DSO9254A 2.5 GHz 10 GSa/s 10 Mpts 4 MSO9254A 2.5 GHz 10 GSa/s 10 Mpts 4 + 16 digital DSO9404A 4 GHz 10 GSa/s 10 Mpts 4 MSO9404A 4 GHz 10 GSa/s 10 Mpts 4 + 16 digital * In 2 ch mode, sample rate and memory depth double Options and accessories Model Description N2900A-020 Upgrade to 20 Mpts of memory N2900A-050 Upgrade to 50 Mpts of memory N2900A-100 Upgrade to 100 Mpts of memory N2900A-200 Upgrade to 200 Mpts of memory N2900A-500 Upgrade to 500 Mpts of memory N2901D DSO9064A to MSO9064A upgrade kit N2901A DSO9104A to MSO9104A upgrade kit N2901B DSO9254A to MSO9254A upgrade kit N2901C DSO9404A to MSO9404A upgrade kit N5473A External DVD-RW with USB connection N2902A 9000 Series oscilloscope rackmount kit N2903A Additional removable hard disk drive (requires option 801 at time of purchase) N4865A GPIB to LAN adapter N2918B Infi niium Evaluation Kit For a complete listing of available Agilent probes, see the Agilent Probes and Accessories Selection Guide, publication number 5989-6162EN. Recommended service options Additional two years of Return-to-Agilent warranty Additional two years of Return-to-Agilent calibrations For more information go to www.agilent.com/find/removealldoubt Product specifi cations and descriptions in this document subject to change without notice. Agilent Technologies, Inc. 2009, Printed in USA, December 8, 2009 5990-3772EN Recommended probes Model Key characteristics N2783A 500-MHz passive probes (standard) 1130A 1.5 GHz Infi niimax probe (optional) 1131A 3.5 GHz Infi niimax probe (optional) Applications Model Description N5462B RS-232/UART triggering and decode E2681A EZJIT jitter analysis software N5384A High-speed SDA and clock recovery N5400A EZJIT Plus jitter analysis software N5464B USB triggering and decode N5463B PCI Express 1.1 triggering and decode N5391B I²C/SPI triggering and decode N8803B CAN/FlexRay triggering and decode N5415B Infi niiscan N5430A User-defi ned function N5452A Application remote programming interface N5461A Infi niisim signal equalization U1882A Power measurement application software N5397A Xilinx FPGA dynamic probe N5433A Altera FPGA dynamic probe N5392A Ethernet compliance application N5416A USB 2.0 compliance application U7233A DDR1 validation application N5413A DDR2 validation application U7231A DDR3 validation application N5467A User-defi nable application N8802A MIPI D-PHY Trigger and decode U7238A MIPI D-PHY compliance N8801A SATA Trigger and compliance For more information on this and other Agilent scopes please visit www.agilent.com/find/9000
Topic 4 HDMI ()
HDMI Active/Passive Cable Test Solution - HDMI () HDMI1.4 Wire/Passive and Active Cable 1>. HDMI Category and Connector Type 2>. HDMI Wire/Passive Cable & Parametric Tests 3>. HDMI Active Cable 4>. Alternative HDMI Cable Eye Diagram Test 5>. HDMI Cable Key Points http://www.litektw.com HDMI Category and Connector Type (Part1) Cable Assembly Maximum Pixel frequency Cable Adaptors Cat 1 74.25 MHz Type A- Type A/C/D Type C- Type C Cat 2 340 MHz Type A- Type A/C/D Type C- Type C Cat 1 with HEAC 74.25 MHz Type A- Type A/C/D Type C- Type C Cat 2 with HEAC 340 MHz Type A- Type A/C/D Type C- Type C Cat 1 Automotive 74.25 MHz Type E- Type E Type E- Type A Relay Receptacle *See Table 4-1 of HDMI 1.4 specification for details Electrical Perform ance See 4.2.6 See 4.2.6 See 4.2.6, Supple ment2 See 4.2.6, Supple ment2 See 4.2.6 Marketing Name Standard High Speed Standard with Ethernet High Speed with Ethernet Only for Automotive Manufactur es Type A- Type A See 4.2.6 Standard Automotive 4-1
HDMI Category and Connector Type (Part2) Type A/E Connector Pin Signal Assignment Pin Signal Assignment 1 TMDS Data 2+ 2 TMDS Data 2 shield 3 TMDS Data 2-4 TMDS Data 1+ 5 TMDS Data 1 shield 6 TMDS Data 1-7 TMDS Data 0+ 8 TMDS Data 0 shield 9 TMDS Data 0-10 TMDS Clock+ 11 TMDS Clock shield 12 TMDS Clock- 13 CEC 14 Utility/ HEAC+ 15 SCL 16 SDA 17 DDC/CEC/HEAC 18 +5V Power GND 19 HPD/ HEAC- 4.45mm P02 P01 P01 1mm P19 13.9mm 21.9mm P19 P02 9.8mm 1.5mm HDMI Category and Connector Type (Part3) Type C Connector Pin Signal Assignment Pin Signal Assignment 1 TMDS Data 2+ shield 11 TMDS Clock+ P01 10.42mm P19 2 TMDS Data 2+ 12 TMDS Clock- 3 TMDS Data 2-13 DDC/CEC/HEAC GND 4 TMDS Data 1 shield 14 CEC 5 TMDS Data 1+ 15 SCL 6 TMDS Data 1-16 SDA 7 TMDS Data 0 shield 17 Utility/ HEAC+ 8 TMDS Data 0+ 18 +5V Power 9 TMDS Data 0-19 HDP/ HEAC- 10 TMDS Clock shield 2.42mm 0.4mm 4-2
HDMI Category and Connector Type (Part4) Type D Connector Pin Signal Assignment Pin Signal Assignment 1 HPD/ HEAC- 2 Utility/ HEAC+ 3 TMDS Data 2+ 4 TMDS Data 2 shield 5 TMDS Data 2-6 TMDS Data 1+ 7 TMDS Data 1 shield 8 TMDS Data 1-9 TMDS Data 0+ 10 TMDS Data 0 shield 11 TMDS Data 0-12 TMDS Clock+ 13 TMDS Clock shield 14 TMDS Clock- 15 CEC 16 DDC/CEC/HEAC GND 17 SCL 18 SDA 19 +5V Power P01 5.83mm P19 2.2mm 0.4mm HDMI Category and Connector Type (Part5) TMDS D0, D1, D2 and CLK Pairs TMDS D0, D1, D2 and CLK Pairs Utility Utility HPD HPD HEAC Pairs GND GND CEC SDA 5V SCL CEC SDA 5V SCL HDMI cable without Ethernet structure HDMI cable with Ethernet structure 4-3
HDMI Wire/Passive Cable (Part1) HDMI Wire cable (without Passive EQ) Only with connector and raw cable. For some purpose, with a short pcb between connector and cable. In low frequency with low loss. HDMI Passive EQ cable (with R, L, C) With R, L, C components in the cable. With a short pcb between connector and cable. With a flat insertion loss trace from low to desired frequency. HDMI Wire/Passive Cable (Part2) HDMI Wire/Passive Cable requirement: Parameter Cat1 (74.25MHz) Cat2 (340MHz) Intra Pair Skew 151 ps 112 ps Inter Pair Skew 2.42 ns 1.78 ns Far End Crosstalk <-20dB <-20dB Attenuation (Insertion Loss) Differential Impedance Connection and transition area(up to 1ns) Cable Area (1ns ~ 2.5ns) See Next page drawing 100 +/- 15 Ohms 100 +/- 10 Ohms A single excursion is permitted out to a maximum of 100 +/- 25 ohms and of a duration of less than 250 ps. 4-4
HDMI Wire/Passive Cable (Part3) HDMI Wire/Passive Cable Attenuation: 8dB 21dB 825MHz 30dB 5dB 12dB 825MHz 2475MHz 20dB 4125MHz 25dB A B C 2475MHz Cat1 Attenuation Cat2 Attenuation Passive Attenuation For 0<x<5, A=0, B=12, C=20 For 5<x<8, A=2.5(x-5), B=3(x-5)+12, C=10/3(x-5)+20 HDMI Wire/Passive Cable (Part4) HDMI Utility/ HEAC requirements: Parameter Utility Line Impedance Intra Pair Skew Differential Impedance Connection and transition area(up to 1ns) Cable Area (1ns ~ 2.5ns) Common Mode Impedance Limit 35.75~74.25 Ohms (Single-ended impedance) 111 ps 100 +/- 15 Ohms (~1ns) 100 +/- 10 Ohms (1~2.5ns) 24 ~36 Ohms (1~2.5ns) HEAC Attenuation limit: 300KHz~10MHz: <1.6dB 10~100MHz: <5dB 100~200MHz: <7.1dB f HEACATT Max( A, B) : A 5[ db], B 0.5[ db], f0 100MHz f 0 4-5
HDMI Wire/Passive Cable (Part5) HDMI Intra Pair Skew Measurement: (TEST ID 5-4) (TEST ID HEACT 6-1) Equipment: 86100C with TDT mode or ENA with Time domain method. Do Deskew of TDR or ENA Setup up the rise-time to 200 ps (10%~90%) Set horizontal to 100 ps/div, vertical to 100 mv/div Mark 100mV for positive and -100mV for negative 86100C-TDR E5071C with opt010 DUT DUT HDMI Wire/Passive Cable (Part6) HDMI Inter Pair Skew Measurement: (TEST ID 5-5) Equipment: 86100C with TDT mode or ENA with Time domain method. Do Deskew of TDR or ENA Setup up the rise-time to 200 ps (10%~90%) Set horizontal to 100 ps/div, vertical to 100 mv/div Mark All TMDS Pairs 100 mv position 86100C-TDR E5071C with opt010 DUT DUT 4-6
HDMI Wire/Passive Cable (Part7) HDMI Far End Crosstalk Measurement: (TEST ID 5-6) Equipment: ENA Set frequency range 300KHz~5GHz Set data points to 1601 Do 4 Port Calibration Terminated with all other un-tested pairs 6 Combinations should be tested: CLK D0, CLK D1, CLK D2, D0 D1, D0 D2, D1 D2. E5071C with opt010 DUT HDMI Wire/Passive Cable (Part8) HDMI Attenuation Measurement: (TEST ID 5-7) (TEST ID HEACT 6-2) Equipment: ENA Set frequency range 300KHz~5GHz Set data points to 1601 Do 4 Port Calibration Terminated with all other un-tested pairs E5071C with opt010 DUT 4-7
HDMI Wire/Passive Cable (Part9) HDMI Differential Impedance Measurement: (TEST ID 5-8) (TEST ID HEACT 6-3) Equipment: 86100C or ENA with Time domain method. Do Deskew of TDR or ENA Setup up the rise-time to 200 ps (10%~90%) Set horizontal to 500 ps/div ~1ns for connector and transition area, 1~2.5 ns for cable area. Terminated with all un-tested pairs. 86100C-TDR E5071C with opt010 DUT DUT HDMI Active Cable Definition: HDMI Active Cable (Part1) With Active Circuits components. Without TX and RX TMDS functions. With Active Equalizer function on D0, D1 and D2 pairs. HDMI Active Cable Application: Thin HDMI Cable (36AWG~40AWG), extended to 5M. Long HDMI Cable up to 25 Meters or longer. 4-8
HDMI Active Cable (Part2) HDMI Active Cable requirement: Parameter Cat1 (74.25MHz) Cat2 (340MHz) Inter Pair Skew 2.42 ns 1.78 ns Differential Impedance Connection and transition area(up to 1ns) Cable Area (1ns ~ 2.5ns) 100 +/- 15 Ohms 100 +/- 10 Ohms A single excursion is permitted out to a maximum of 100 +/- 25 ohms and of a duration of less than 250 ps. Alternative HDMI Cable Eye Diagram Test (Part1) HDMI Eye Diagram test: Equipments for measurements: N4903B (Signal Generator), 86100C (As Scope) HDMI Test fixtures Active Test Fixture for Active Cable. Passive Test Fixture for Wire/ Passive Cable. 4-9
Alternative HDMI Cable Eye Diagram Test (Part2) HDMI Eye Diagram test: Calibrate Differential voltage swing to 800 mv Calibrate Jitter with 0.3Tbit To PPG To Scope or TDR HDMI Power Supply Module HAT-18 HAT-17 SMA Power Adapters Fig5: Eye Diagram Calibration drawing Alternative HDMI Cable Eye Diagram Test (Part3) HDMI Eye Diagram test: Cable without Active Module Cable with Active Module DUT 4-10
HDMI Cable Key Points (Part1) For Wire/Passive Cable: Cable which passed Insertion Loss of Cat2 will pass Eye diagram. Large Intra pair skew value will let the insertion loss worse. Take care the peeled length of STP structure for impedance and Far End Crosstalk. Since P14 is far to P19 of Type A connector, HEAC Common Mode Impedance is not easy to pass. For Active Cable: For thin cable, be care the DC voltage drop. For long cable, be care the capacitance will be out of specification. Active cable is not suitable for short length. If the sink device is designed with active Equalizer function, it may hit the high and low limit eye mask. 4-11
Agilent 86100C Infiniium DCA-J Eye diagram/mask test and jitter analysis for next-generation components and systems NEW Modules 86105D 8x FC, 10G and 16x FC (14.025 Gb/s) reference receivers, 750-1650 nm, 20 GHz optical bandwidth 86116C-025 100 GbE 25 Gb/s reference receiver 86116C-040 wide-bandwidth 40 Gb/s reference receiver Increase yield and test margins of high-performance designs With over 33 GHz bandwidth and residual jitter below 60 fs, the 86108A Precision Waveform Analyzer allows you to see the true performance of your best designs. Jitter Analysis on very long or random data patterns 86100CU-401 Advanced Eye Analysis software allows separation of jitter into random and deterministic components as well as estimates of total jitter on any data pattern, including random data. (External PC and Microsoft Excel 2003/2007 required) Seconds UI RJ 1.2E-12 13.4E-3 DJ (d-d) 5.0E-12 54.0E-3 TJ 22.6E-12 242.1E-3 TJ probability 1.0E-12
Fast, automated mask margin test TWDP on-board calculation www.agilent.com www.agileny.com/find/dca For more information on Agilent Technologies products, applications or services, please contact your local Agilent office. The complete list is available at: www.agilent.com/find/contactus Phone Easily determine eye-mask margins to a no-hit or user defined hit ratio (802.3ah, aq, ba etc.). (New feature with revision A.08.00) I-Q diagrams for complex modulation receiver test Convert receiver outputs to I-Q diagrams to visualize how receivers detect advanced communications signals New feature at revision A.08.10 Jitter spectrum/jitter transfer function TWDP, xwdp or general MATLAB(R) analysis performed real-time in the oscilloscope. No external PC required. Option 201 and MATLAB required) 86105D broad wavelength plug-in module 20 GHz optical bandwidth 750 to 1650 nm, 62.5/125 µm fiber Reference receiver: 8.5 G, 9.95 G, 10.3 G, 10.5 G, 14.025 Gb/s (16x FC) 35 GHz electrical channel The 86100C DCA-J allows jitter spectrum analysis on both data and clock signals to diagnose the root causes of difficult jitter problems. In conjunction with a jitter source such as the N4903A/B J-BERT, Jitter Transfer Function or PLL loop bandwidth can be easily and quickly characterized. The software is downloadable for free, Works only with either 86108A or 83496B. External PC and Microsoft Excel 2003/2007 required. Americas Canada (877) 894-4414 Latin America 305 269 7500 United States (800) 829-4444 Asia Pacific Australia 1 800 629 485 China 800 810 0189 Hong Kong 800 938 693 India 1 800 112 929 Japan 012 (421) 345 Korea 080 769 0800 Malaysia 1 800 888 848 Singapore 1 800 375 8100 Taiwan 0800 047 866 Thailand 1 800 226 008 Europe Austria 01 36027 71571 Belgium 32 (0) 2 404 93 40 Denmark 45 70 13 15 15 Finland 358 (0) 10 855 2100 France 0825 010 700 Germany 07031 464 6333 Ireland 1890 924 204 Isreal 972-3-9288-504/544 Italy 39 02 92 60 8484 Netherlands 31 (0) 20 547 2111 Spain 34 (91) 631 3300 Sweden 0200-88 22 55 Switzerland 0800 80 53 53 United Kingdom 44 (0) 118 9276201 Other European countries: www.agilent.com/find/contactus Revised: October 1, 2008 Product specifications and descriptions in this document subject to change without notice. Agilent Technologies, Inc. 2001, 2009 Printed in USA, March 20, 2009 5990-3814EN
http://www.agilent.com/find/service 0800-047866 Agilent CertiPrime www.agilent.com.tw/find/certiprime
www.agilent.com.tw & www.agilent.com.tw/find/events www.agilent.com.tw/find/handouts 104 27 (02) 8772-5888 324 20 (03) 492-9666 802 6251 (07) 535-5035 2007 Printed in Taiwan 1/2010 5990-5268ZHA Agilent Email Updates www.agilent.com.tw/find/emailupdates