RAID RAID 0 RAID 1 RAID 5 RAID * ( -1)* ( /2)* No Yes Yes Yes A. B. BIOS SATA C. RAID BIOS RAID ( ) D. SATA RAID/AHCI ( ) SATA M.2 SSD ( )

Similar documents
RAID RAID 0 RAID 1 RAID 5 RAID * (-1)* (/ 2)* No Yes Yes Yes SATA A. B. BIOS SATA C. RAID BIOS RAID ( ) D. RAID/AHCI ( ) S ATA S S D ( ) (

Guide to Install SATA Hard Disks

Serial ATA ( Silicon Image SiI3114)...2 (1) SATA... 2 (2) B I O S S A T A... 3 (3) RAID BIOS RAID... 5 (4) S A T A... 8 (5) S A T A... 10

IT (1) IDE... 2 (2) BIOS IDE RAID... 3 (3) RAID BIOS RAID... 5 (4) R A I D (5) ID E RA ID... 15

Ác Åé å Serial ATA ( Sil3132) S A T A (1) SATA (2) BIOS SATA (3)* RAID BIOS RAID (4) SATA (5) SATA (a) S A T A ( S A T A R A I D ) (b) (c) Windows XP

Serial ATA ( Nvidia nforce430)...2 (1) SATA... 2 (2) B I O S S A T A... 3 (3) RAID BIOS RAID... 6 (4) S A T A... 9 (5) S A T A (6) Microsoft Win

K7VT2_QIG_v3

Serial ATA ( nvidia nforce4 Ultra/SLI)...2 (1) SATA... 2 (2) B I O S S A T A... 3 (3) RAID BIOS RAID... 6 (4) S A T A... 9 (5) S A T A (6) Micro

Serial ATA ( Silicon Image SiI3512)...2 (1) SATA... 2 (2) B I O S S A T A... 3 (3) RAID BIOS RAID... 5 (4) S A T A... 8 (5) S A T A... 10

Ác Åé å Serial ATA ( nvidia nforce4 SLI) S A T A (1) SATA (2) BIOS SATA (3)* RAID BIOS RAID (4) SATA (5) SATA (a) S A T A ( S A T A R A I D ) (b) (c)

P4VM800_BIOS_CN.p65

P4Dual-915GL_BIOS_CN.p65

Windows 2000 Server for T100

P4V88+_BIOS_CN.p65

Ác Åé å Serial ATA ( nvidia nforce4-4x; nvidia nforce3 250/Ultra; nvidia nforce2 MCP RAID) S A T A (1) SATA (2) BIOS SATA (3)* RAID BIOS RAID (4) SATA

775i65PE_BIOS_CN.p65

P4i45GL_GV-R50-CN.p65

SA-DK2-U3Rユーザーズマニュアル

第4章 系统设置

LSI U320 SCSI卡用户手册.doc

T

如 果 此 設 備 對 無 線 電 或 電 視 接 收 造 成 有 害 干 擾 ( 此 干 擾 可 由 開 關 設 備 來 做 確 認 ), 用 戶 可 嘗 試 用 以 下 一 種 或 多 種 方 法 來 消 除 這 個 干 擾 : 重 新 調 整 與 確 定 接 收 天 線 方 向 增 大 此 設

穨FT66_CMan_0814.PDF

穨FT100_CMan_0815.PDF

AL-MX200 Series

TPM BIOS Infineon TPM Smart TPM Infineon TPM Smart TPM TPM Smart TPM TPM Advanced Mode...8

T

典型自编教材

T1028_Manual_KO_V3 0.pdf

(Load Project) (Save Project) (OffLine Mode) (Help) Intel Hex Motor

RAID 简介 : RAID 0 RAID 1 RAID 5 RAID 10 硬盘数目 总容量 硬盘数目 * 容量最小容量最小的硬盘 ( 硬盘数目 -1)* 容量 ( 硬盘数目 /2)* 容量的硬盘最小的硬盘最小的硬盘 容错功能 No Yes Yes Yes 若要构建完整的 SATA

Windows 2000 Server for T100

CHN_p000A_Cover.ai

HighPoint产品的FAQ手册

AL-M200 Series

Cadence SPB 15.2 VOICE Cadence SPB 15.2 PC Cadence 3 (1) CD1 1of 2 (2) CD2 2of 2 (3) CD3 Concept HDL 1of 1

穨TX2使用手冊草稿.PDF

1.ai

Chapter 2

Dell Vostro 14–3459 用户手册

Windows 2000 Server for T100

Symantec™ Sygate Enterprise Protection 防护代理安装使用指南

产品手册

2 : ; :

audiogram3 Owners Manual

IP505SM_manual_cn.doc

TX-NR3030_BAS_Cs_ indd

<55342D323637CBB5C3F7CAE92E786C73>

els0xu_zh_nf_v8.book Page Wednesday, June, 009 9:5 AM ELS-0/0C.8

untitled

Cover-YP-35-ch

QNAP Turbo NAS Software User Manual

CA-C750К


+01-10_M5A_C1955.p65

Product Specification Chip Connectors Interface Data Transfer Rate Intel DSL5520 Thunderbolt 2 Controller 2 x Thunderbolt 2 ports (TBT 1/TBT 2), suppo

Logitech Wireless Combo MK45 English

相 关 知 识 1 计 算 机 工 作 原 理 1946 年 2 月, 世 界 上 第 一 台 电 子 计 算 机 ENIAC (Electronic Numerical Integrator And Computer, 电 子 数 字 积 分 计 算 机 ) 诞 生 于 美 国 宾 夕 法 尼 亚

ebook140-9

P3V4X JumperFree TM

Microsoft Word _TC_Lemel_new.doc

Hitachi Vantara Hitachi Vantara Hitachi, Ltd. Hitachi Vantara IT OT Go Go

CL-S10w

2 EZ 模 式 默 认 情 况 下, 进 入 BIOS 设 置 程 序 时,EZ Mode ( EZ 模 式 ) 屏 幕 会 出 现 EZ 模 式 是 一 个 仪 表 盘, 包 含 系 统 当 前 状 态 的 多 个 读 数 您 可 以 检 查 系 统 最 重 要 的 信 息, 如 : CPU 速

CANVIO_AEROCAST_CS_EN.indd

Microsoft PowerPoint - AWOL - Acrobat Windows Outlook.ppt [Compatibility Mode]

Sun StorEdge 3000 系列安装、操作和维护手册 (3310)

S325A 2

GoFlex Home UG Book.book

f2.eps

IBM System x 系列手册

untitled

P3B-F Pentium III/II/Celeron TM

1692_UG.book

User’s Manual

Microsoft Word doc

尊 敬 的 中 磐 服 务 器 用 户 : 衷 心 感 谢 您 选 用 中 磐 服 务 器! 本 手 册 介 绍 了 中 磐 E3VX 塔 式 单 路 服 务 器 的 技 术 特 性 与 系 统 的 设 置 安 装, 有 助 于 您 更 详 细 地 了 解 和 便 捷 地 使 用 此 款 服 务 器

GA-8IG P4 533 Pentium Rev MC-8IG-1201

HY144-D-SRC 固件升级指南

EK-STM32F

C10_ppt.PDF

Microsoft Word - Front cover_white.doc

(Guangzhou) AIT Co, Ltd V 110V [ ]! 2

cosa Quick Start Manual

KDC-U5049 KDC-U4049 Made for ipod, and Made for iphone mean that an electronic accessory has been designed to connect specifically to ipod, or iphone,

ARM JTAG实时仿真器安装使用指南

MSAC-EX1

操作指导手册

Microsoft Word - template.doc

Data Management Software CL-S10w

國 立 政 治 大 學 教 育 學 系 2016 新 生 入 學 手 冊 目 錄 表 11 國 立 政 治 大 學 教 育 學 系 博 士 班 資 格 考 試 抵 免 申 請 表 論 文 題 目 申 報 暨 指 導 教 授 表 12 國 立 政 治 大 學 碩 博 士 班 論

Dell EMC Data Domain DDOS 5.5 Data Domain Data Domain Data Domain : Data Domain Boost (DDBoost) Dell EMC DDBoost Data Domain DDBoost Source De-Dup Bac

CONTENTS Chapter - Introduction Chapter 2 - Hardware Installation Chapter 3 - BIOS Setup Utility Chapter 4 - Supported Software M804

User ID 150 Password - User ID 150 Password Mon- Cam-- Invalid Terminal Mode No User Terminal Mode No User Mon- Cam-- 2

Microsoft Word - PS2_linux_guide_cn.doc

请 先 阅 读 本 节! 表 示 安 全 信 息 警 告 : 为 了 减 少 火 灾 或 电 击 的 危 险, 不 要 让 本 机 受 到 雨 淋 或 放 置 在 潮 湿 的 地 方 为 减 少 火 患 或 电 击 的 危 险, 本 设 备 应 避 开 一 切 使 用 液 体 的 场 合, 并 只

Move Component Object selection Component selection UV Maya Hotkeys editor Maya USING MAYA POLYGONAL MODELING 55

User’s Manual

Transcription:

RAID RAID 0 RAID 1 RAID 5 RAID 10 2 2 3 4 * (-1)* (/2)* No Yes Yes Yes A. B. BIOS SATA C. RAID BIOS RAID ( ) D. SATA RAID/AHCI ( ) SATA M.2 SSD ( ) ( ) ( ) Windows USB 1 SATA A. SATASATAIntel SATA (SATA3 0~5)M.2 SSD M.2 ( ) ( ) ( ) RAID M.2 PCIe SSD M.2 SATA SSD SATA SATA M.2 SSD M.2 Socket 3-1 -

B. BIOS SATA BIOS SATA BIOS POST<Delete> BIOSPeripherals\SATA ConfigurationSATA Controller(s) RAID SATA Mode Selection RAID ( 1) 1 UEFI RAID C-1 RAID ROMC-2 BIOS BIOS BIOS - 2 -

C-1. UEFI RAID Windows 10/8.1 64-bit BIOS BIOS Features Windows 8/10 Features Windows 8/10 CSM SupportDisabled ( 2) 2 BIOS BIOS Peripherals\Intel(R) Rapid Storage Technology ( 3) 3-3 -

Intel(R) Rapid Storage TechnologyCreate RAID Volume<Enter> Create RAID VolumeName 16 <Enter>RAID Level RAID ( 4) RAID RAID 0(Stripe) RAID 1(Mirror) Recovery RAID 10 RAID 5 ( RAID )RAIDSelect Disks 4 Select Disks <Space> X(Stripe Size) ( 5) 4 KB 128 KB (Capacity) 5-4 -

Create Volume () Create Volume <Enter> ( 6) 6 Intel(R) Rapid Storage TechnologyRAID Volumes <Enter> ( 7) 7-5 -

Intel(R) Rapid Storage Technology <Enter> RAID VOLUME INFODelete <Enter> Yes<Enter> ( 8) 8-6 -

C-2 RAID ROM Intel RAID BIOS SATA RAID RAID BIOS POST ( 9) <Ctrl> + <I> RAID BIOS RAID Volumes : None defined. Physical Devices : ID Device Model Serial # Size Type/Status(Vol ID) 1 Hitachi HDS72105 JP1532ER04EJTK 465.7GB Non-RAID Disk 2 Hitachi HDS72105 JP1532ER046AGK 465.7GB Non-RAID Disk Press <CTRL - I> to enter Configuration Utility... 9 <Ctrl> + <I>RAID( 10) (Create RAID Volume) Create RAID Volume<Enter>RAID 1. Create RAID Volume 2. Delete RAID Volume 3. Reset Disks to Non-RAID [ MAIN MENU ] 4. Recovery Volume Options 5. Acceleration Options 6. Exit RAID Volumes : None defined. [ DISK/VOLUME INFORMATION ] Physical Deivces : ID Device Model Serial # Size Type/Status(Vol ID) 1 Hitachi HDS72105 JP1532ER04EJTK 465.7GB Non-RAID Disk 2 Hitachi HDS72105 JP1532ER046AGK 465.7GB Non-RAID Disk [hi]-select [ESC]-Exit [ENTER]-Select Menu 10-7 -

CREATE VOLUME MENUName 16 <Enter>RAID (RAID Level) ( 11) RAID RAID 0 RAID 1 Recovery RAID 10 RAID 5 (RAID )RAID <Enter> [ CREATE VOLUME MENU ] Name : Volume0 RAID Level : RAID0(Stripe) Disks : Select Disks Strip Size : 16KB Capacity : 931.5 GB Sync : N/A Create Volume [ HELP ] RAID 0: Stripes data (performance). [hi]-change [TAB]-Next [ESC]-Previous Menu [ENTER]-Select 11 Disks (Strip Size) ( 12) 4 KB 128 KB <Enter> (Capacity) [ CREATE VOLUME MENU ] Name : Volume0 RAID Level : RAID0(Stripe) Disks : Select Disks Strip Size : 16KB Capacity : 931.5 GB Sync : N/A Create Volume [ HELP ] The following are typical values: RAID0-128KB RAID10-64KB RAID5-64KB [hi]-change [TAB]-Next [ESC]-Previous Menu [ENTER]-Select 12-8 -

<Enter>Create Volume () Create Volume <Enter> <Y> <N> ( 13) Copyright(C) Intel Corporation. All Rights Reserved. [ CREATE VOLUME MENU ] Name : Volume0 RAID Level : RAID0(Stripe) Disks : Select Disks Strip Size : 128 MB Capacity : 931.5 GB Sync : N/A Create Volume WARNING : ALL DATA ON SELECTED DISKS WILL BE LOST. [ HELP ] Are you sure you want to create this volume? (Y/N) : Press ENTER to create the specified volume. [hi]-change [TAB]-Next [ESC]-Previous Menu [ENTER]-Select 13 DISK/VOLUME INFORMATION ( 14) 1. Create RAID Volume 2. Delete RAID Volume 3. Reset Disks to Non-RAID [ MAIN MENU ] 4. Recovery Volume Options 5. Acceleration Options 6. Exit [ DISK/VOLUME INFORMATION ] RAID Volumes : ID Name Level Strip Size Status Bootable 0 Volume0 RAID0(Stripe) 128KB 931.5GB Normal Yes Physical Devices : ID Device Model Serial # Size Type/Status(Vol ID) 1 Hitachi HDS72105 JP1532ER04EJTK 465.7GB Member Disk(0) 2 Hitachi HDS72105 JP1532ER046AGK 465.7GB Member Disk(0) [hi]-select [ESC]-Exit [ENTER]-Select Menu 14 <Esc> 6. Exit <Enter> RAID - 9 -

(Recovery Volume Options) Intel (Rapid Recover Technology) RAID 1 (Master Drive) (Recovery Drive) Recovery Volume RAID 1. Create RAID Volume ( 15) 1. Create RAID Volume 2. Delete RAID Volume 3. Reset Disks to Non-RAID [ MAIN MENU ] 4. Recovery Volume Options 5. Acceleration Options 6. Exit RAID Volumes : None defined. [ DISK/VOLUME INFORMATION ] Physical Disks : ID Drive Model Serial # Size Type/Status(Vol ID) 1 Hitachi HDS72105 JP1532ER04EJTK 465.7GB Non-RAID Disk 2 Hitachi HDS72105 JP1532ER046AGK 465.7GB Non-RAID Disk [hi]-select [ESC]-Exit [ENTER]-Select Menu 15 RAID LevelRecovery <Enter> ( 16) [ CREATE VOLUME MENU ] Name : Volume0 RAID Level : Recovery Disks : Select Disks Strip Size : N/A Capacity : 465.7 GB Sync : Continuous Create Volume [ HELP ] Recovery: Copies data between a master and a recovery disk. [hi]-change [TAB]-Next [ESC]-Previous Menu [ENTER]-Select 16-10 -

Select Disks <Enter> SELECT DISKS <Tab> <Space> ( ) <Enter> ( 17) [ CREATE VOLUME MENU ] Name : Volume0 RAID Level : Recovery Disks [ SELECT : Select DISKS Disks ] Strip Size : 128KB Capacity : 223.6 GB ID Drive Model Serial # Create Volume Size Status M1 Hitachi HDS72105 JP1532ER04EJTK 465.7GB Non-RAID Disk R2 Hitachi HDS72105 JP1532ER046AGK [ HELP ] 465.7GB Non-RAID Disk Choose the RAID level: RAID0: Stripes data (performance). Select 1 Master RAID1: and 1 Recovery Mirrors disk data to (redundancy). create volume. Recovery: Copies data between a master and a recovery disk. RAID10: Mirrors data and stripes the mirror. [hi]-prev/next [TAB]-(M)aster RAID5: Stripes [SPACE]-(R)ecovery data and parity. [ENTER]-Done [hi]-change [TAB]-Next [ESC]-Previous Menu [ENTER]-Select 17 Sync Continuous On Request ( 18) (Continuous Update) (Update On Request) Intel [ CREATE VOLUME MENU ] Name : Volume0 RAID Level : Recovery Disks : Select Disks Strip Size : N/A Capacity : 0.0 GB Sync : Continuous Create Volume [ HELP ] Select a sync option: On Request: volume is updated manually Continuous: volume is updated automatically [hi]-change [TAB]-Next [ESC]-Previous Menu [ENTER]-Select 18 Create Volume <Enter> - 11 -

(Delete RAID Volume) Delete RAID Volume DELETE VOLUME MENU<Delete> <Y> <N> ( 19) [ DELETE VOLUME MENU ] Name Level Drives Capacity Status Bootable Volume0 RAID0(Stripe) 2 931.5GB Normal Yes [ DELETE VOLUME VERIFICATION ] ALL DATA IN THE VOLUME WILL BE LOST! (This does not apply to Recovery volumes) Are you sure you want [ HELP to delete ] "Volume0"? (Y/N) : Deleting a volume will reset the disks to non-raid. WARNING: ALL DISK DATA WILL BE DELETED. (This does not apply to Recovery volumes) [hi]-select [ESC]-Previous Menu [DEL]-Delete Volume (Acceleration Options) 19 I ntel / ( 20) Intel Intel RAID ROM/ ( ) Acceleration Options // <R> <Y> / <S> <Y> [ ACCELERATION OPTIONS ] Name Type Capacity Mode Status DISK PORT 3 Non-RAID Disk 465.7GB Enhanced In Sync [ HELP ] Press 's' to synchronize data from the cache device to the Accelerated Disk/Volume Press 'r' to remove the Disk/Volume Acceleration WARNING: IT IS RECOMMENDED THAT YOU PERFORM A SYNCHRONIZATION BEFORE REMOVING ACCELERATION [hi]-select 20 [ESC]- Previous Menu - 12 -

2 SATA RAID/AHCI BIOS SATA A. SATA RAID/AHCI Xpress Install SATA RAID/AHCI \Boot IRST-x64 IRST-x86 USB ( ) USB ( IRST-x64 IRST-x86 ) 1Intel Chipset SATA RAID Controller 1-13 -

B. RAID 1 RAID 5 RAID 10 RAID 1 ( ) Press <Ctrl-I> to enter Configuration Utility <Ctrl> + <I> Intel RAID BIOS [ MAIN MENU ] 1. Create RAID Volume[ DEGRADED VOLUME DETECTED 3. ] Reset Disks to Non-RAID "Degraded 2. Delete volume RAID and disk Volume available for rebuilding detected. Selecting 4. Exit a disk initiates a rebuild. Rebuild completes in the operating system. Select the port of the destination disk [ DISK/VOLUME for rebuilding (ESC INFORMATION to exit): ] RAID Volumes : None defined. ID Drive Model Serial # Size 5 Hitachi HDS721050CLA JP1532FR046M2K 465.7GB Physical Disks : ID Drive Model [hi]-previous/next Serial # [ENTER]-Select Size Type/Status(Vol [ESC]-Exit ID) 4 Hitachi HDS72105 JP1532ER04EJTK 465.7GB Member Disk (0) 5 Hitachi HDS72105 JP1532FR046M2K 465.7GB Non-RAID Disk [hi]-select [ESC]-Exit [ENTER]-Select Menu <Enter> ( ) 1. Create RAID Volume 2. Delete RAID Volume 3. Reset Disks to Non-RAID [ MAIN MENU ] 4. Recovery Volume Options 5. Acceleration Options 6. Exit [ DISK/VOLUME INFORMATION ] RAID Volumes : ID Name Level Strip Size Status Bootable 0 Volume0 RAID1(Mirror) N/A 465.7GB Rebuild Yes Physical Devices : ID Devices Model Serial # Size Type/Status(Vol ID) 4 Hitachi HDS72105 JP1532ER04EJTK 465.7GB Member Disk (0) 5 Hitachi HDS72105 JP1532FR046M2K 465.7GB Non-RAID Disk Volumes with "Rebuild" status will be rebuilt within the operating system. [hi]-select [ESC]-Exit [ENTER]-Select Menu - 14 -

Intel Intel - 15 -

(Recovery Volume) Recovery Volume (Update on Request) Intel R AID BIOS 4. Recover y Volume Options RECOVERY VOLUME OPTIONS Enable Only Recovery Disk RAID BIOS [ RECOVERY VOLUME OPTIONS ] 1. Enable Only Recovery Disk 2. Enable Only Master Disk [ SELECT RECOVERY VOLUME ] Name Level Capacity [ HELP ] Status Bootable } Volume0 Recovery(OnReq) 465.7GB NeedsUpdate Yes Choose the RAID level: RAID0: Stripes data (performance). RAID1: Mirrors data (redundancy). Recovery: Select a Copies Recovery data volume between to a do master the operation. and a recovery disk. RAID10: Mirrors data and stripes the mirror. RAID5: Stripes data and parity. [hi]-up/down [SPACE]-Selects [ENTER]-Done [hi]-select [ESC]-Previous Menu [ENTER]-Select Intel - 16 -