全汉不间断电源 全汉集团始于 1993 Began in 1993 UPS
专业卓越共赢 Professional excellence and win-win 目录 about company 1 1-3k 2 6-10k 3 RM 1-3k 4 RM 6-10k 5 RT 1-3K 6 RT 6-10K 7 3/1 10-30K 8 3/3 10-30K 9 3/3 40-200K 10 Mplus 30-210K
1000 VA / 800 W 2000 VA / 1600 W 3000 VA / 2400 W 100/110/115/120/127VAC 200/208/220/230/240VAC 55-145 VAC 110-300 VAC 40Hz ~ 70 Hz 0.99 @ Nominal Voltage (100% ) 100/110/115/120/127VAC 200/208/220/230/240VAC () ± 1% () 47~ 53 Hz 57 ~ 63 Hz () 50 Hz 60Hz ± 0.1 Hz 3:1 Knight Knight 1K (L) Knight 2K (L) Knight 3K (L) 3 % THD () 6 % THD () 88% 89% 90% 83% 87% 88% 12 V / 9 AH 12 V / 9 AH 12 V / 9 AH 2 4 6 4 90% 1.0 A 27.4VDC ± 1% 54.7 VDC ±1% 82.1 VDC ±1% * 2 3 4 6 6 8 1.0A/2.0A/4.0A/6.0 A 27.4VDC ± 1% 41.0VDC ± 1% 54.7 VDC ±1% 82.1 VDC ±1% 82.1 VDC ±1% 109.4VDC ±1% LCD 4 1 1 282 x 145 x 220 397 x 145 x 220 421 x 190 x 318 (kgs) 9.8 17 27.6 * 282 x 145 x 220 397 x 145 x 220 4.1 6.8 7.4 20-90 % RH @ 0-40 C () 50dBA @ 1 Smart RS-232/USB Windows 2000/2003/XP/Vista/2008, Windows 7/8, Linux, Unix, and MAC SNMP SNMP * 200/208/220/230/240VAC ***100/200/208VAC80% * 4000-870-558 www.quanhan-tw.com
Knight 6K(L)/10K(L)
Knight 6K/10K Knight 6K(L) Knight 10K(L) 6000 VA / 4800 W 10000 VA / 8000 W 3 % THD () 6 % THD () 3 % THD () 6 % THD () 89% 90% 88% 89% 12 V / 7 AH 12 V / 9 AH 16 16 9 90% 9 90% :1.0 A ± 10%, :2.0A ± 10% :1.0 A ± 10%,.:2.0A ± 10% 218.4 VDC ± 1% 218.4 VDC ± 1% 16-20** () :4.0 A ± 10%,.:6.0A ± 10% :4.0 A ± 10%,.:6.0A ± 10% 273 VDC ± 1%(20 pcs), x x (mm) 369 x 190 x 688 442 x 190 x 688 (kgs) 60 75, x x (mm) 369 x 190 x 318 442 x 190 x 318 (kgs) 21 23 55dBA @ 1 208/220/230/240VAC 176-300 VAC ± 3% @ 100% 110-300 VAC ± 3% @ 50% 46 Hz ~ 54 Hz 56 Hz ~ 64 Hz 0.99 @ 100% 208/220/230/240VAC () ± 1% () 46 Hz ~ 54 Hz 56 Hz ~ 64 Hz () 50 Hz ± 0.1 Hz 60 Hz ± 0.1 Hz 3:1 () LCD 4 4 0-95 % RH @ 0-40 C () 58dB @ 1 RS-232/USB SNMP Windows 2000/2003/XP/Vista/2008, Windows 7/8, Linux, Unix, and MAC SNMP * UPS, 40%, UPS 208VAC, 10%. *** 1000, 100m 1% 4000-870-558 www.quanhan-tw.com
RM Knight RM 2K(L) 1000 VA / 800 W 1500 VA / 1200 W 2000 VA / 1600 W 3000 VA / 2400 W 200/208/220/230/240VAC 110-300 VAC ±5% 40Hz ~ 70 Hz 0.99 @ Nominal Voltage (100% ) 200/208/220/230/240VAC () ± 1% () 47~ 53 Hz 57 ~ 63 Hz () 50 Hz ± 0.25Hz 60Hz ± 0.3 Hz 3:1 87% 90% 83% 87% 89% 12 V / 9 AH 2 12 V / 9 AH 3 12 V / 9 AH 4 12 V / 9 AH 6 4 90% 1.0 A 27.4VDC ± 1% 41.1VDC ± 1% 54.8VDC ± 1% 82.1VDC ± 1% * 1.0A/2.0A/4.0A/6.0A ± 10% - 41.0VDC ± 1% 82.1VDC ± 1%109.4VDC ± 1% 82.1VDC ± 1%109.4VDC ± 1% LCD 4 1 1 (kgs) 380 x 438 x 88 13.2 380 x 438 x 88 6.5 Knight Knight RM 1K (L) Knight RM 1.5K (L) Knight RM 3K (L) * Smart RS-232/USB SNMP 480 x 438 x 88 18.5 480x 438 x 88 10.7 ***100/200/208VAC80% * 3 % THD () 6 % THD () 480 x 438 x 88 20.6 380x 438 x 88 8.3 20-90 % RH @ 0-40 C () 50dBA @ 1 Windows 2000/2003/XP/Vista/2008, Windows 7/8, Linux, Unix, and MAC SNMP 600 x 438 x 88 29 480x 438 x 88 10 4000-870-558 www.quanhan-tw.com
Knight RM 6K(L) Knight RM 10K(L) 6000 VA / 4800 W 10000 VA / 8000 W 208/220/230/240VAC () () LCD RS232/USB SNMP 89% 90% 88% 89% 12 V / 9 AH 12 V / 9 AH 16 pcs 20 pcs 990% :1.0 A ± 10%, :2.0A ± 10% :1.0 A ± 10%, :2.0A ± 10% 218.4 VDC ± 1% 273 VDC ± 1% (20) 16-20** () :4.0 A ± 10%, :6.0A ± 10% :4.0 A ± 10%, :6.0A ± 10% 273 VDC ± 1% (20), x x (mm) (kgs) Knight 6K/10K RACK 176-300 VAC ± 3% @ 100% 110-300 VAC ± 3% @ 50% 46Hz ~ 54 Hz 56Hz ~ 64 Hz 0.99 @ 100% 208/220/230/240VAC () ± 1% UPS: 580x438x88 [2U] : 580x438x133 [3U] UPS: 15 : 48 UPS: 668x438x88 [2U] : 580x438x133[3U] UPS: 18 : 63, x x (mm) 580 x 438 x 88 [2U] 668 x 438 x 88[2U] (kgs) 15 18 55dBA @ 1 ***100/200/208VAC60% *** 1000, 100m 1% * 46Hz ~ 54 Hz 56Hz ~ 64 Hz 50 Hz ± 0.1 Hz 60 Hz ± 0.1 Hz 3:1 () 3 % THD (), 5 % THD () 4 1 0-95 % RH @ 0-40 C () SNMP 58dBA @ 1 Windows 2000/2003/XP/Vista/2008, Windows 7/8, Linux, Unix, and MAC 4000-870-558 www.quanhan-tw.com
Custos 9X + 1KVA/1.5KVA/2KVA/3KVA RACK/TOWER Custos 9X + 1K Custos 9X+ 1K(L) Custos 9X + 1.5K Custos 9X + 1.5K(L) Custos 9X + 2K Custos 9X + 2K(L) Custos 9X + 3K Custos 9X + 3K(L) 1000 VA 1500 VA 2000 VA 3000 VA 900 W 800 W 1350 W 1200 W 1800 W 1600 W 2700 W 2400 W 100*/110*/115*/120 VAC 208/220/230/240 VAC 55-150 VAC ± 5% 110-300 VAC ± 5% 40Hz ~ 70 Hz () ± 1% () 47 ~ 53 Hz 57 ~ 63 Hz () 50 Hz ± 0.5% 60Hz ± 0.5% 5:1 () 2 % THD (); 8 % THD () 4 ms () 86% (), 88% () 88% (), 90% () 83% (), 86% () 85% (), 88% () 12 V / 9 AH 12 V / 9 AH 12 V / 9 AH 12 V / 9 AH 2 3 4 6 490% 490% 490% 490% 1.0 A 4A 8 A 1.0 A 4A 8 A 1.0 A 4A 8 A 1.0 A 4A 8 A 27.4 VDC ± 1% 41.1 VDC ± 1% 54.7 VDC ±1% 82.1 VDC ±1% LCD, x x (mm) 380 x 438 x 88[2U] 480 x 438 x 88[2U] 480 x 438 x 88[2U] 600 x 438 x 88[2U] (kgs)) RS-232/USB SNMP 12.9 8.6 17.6 10.7 20.6 11.3 28 13.8 ***115/110/100VAC95%/90%/80% * 0.99 @ nominal voltage (100% ) 100*/110*/115*/120 VAC 208/220/230/240 VAC 4 1 1 20-90 % RH @ 0-40 C () 50dBA @ 1 Windows 2000/2003/XP/Vista/2008, Windows 7/8, Linux, Unix, and MAC SNMP 4000-870-558 www.quanhan-tw.com
Custos 9X + 6K/10K RACK/TOWER Custos 9X + 6K Custos 9X + 10K 6000 VA / 5400 W 10000 VA / 9000 W 200/208/220/230/240 VAC 176-300 VAC (100% ) 110-300 VAC (50% ) 46~54 Hz 56~64 Hz 0.99 @ 100% 200/208/220/230/240 VAC 200/208/220/230/240 VAC () ± 1% () 46~54 Hz 56~64 Hz () 50 Hz ± 0.1 Hz 60 Hz ± 0.1 Hz 3:1 () ECO 2 % THD () 4 % THD () 2 % THD () 4 % THD () 90% 90% 88% 88% 96% 96% 240 VDC 12 V / 7 AH 12 V / 9 AH 20 (18-20 pcs )* 20 (18-20 pc 790% 990% 1.0 A 1.0 A / 273 VDC (20) 4.0 A 4.0 A 273 VDC (20) LCD 4 1, x x (mm) UPS: 580 x 438 x 133 : 580 x 438 x 133 UPS: 668 x 438 x 133 : 580 x 438 x 133 (kgs)) UPS: 20 : 57 UPS: 23.5 63 RS-232/USB SNMP, x x (mm) 580 x 438 x 133 668 x 438 x 133 (kgs)) 20 23.5 58dBA @ 1 0-95 % RH @ 0-40 C () SNMP 60dBA @ 1 Windows 2000/2003/XP/Vista/2008, Windows 7/8, Linux, Unix, and MAC *** 1000, 100m 1% * L * 4000-870-558 www.quanhan-tw.com
Proline 3P/1P 10K/15K/20K/30K Proline 3/1-10K (L) Proline 3/1-15K (L) Proline 3/1-20K (L) Proline 3/1-30K (L) 10000 VA / 8000 W 15000 VA / 12000 W 20000 VA / 16000 W 30000 VA / 24000 W 89% 89% 89% 90% 86% 88% 87% 89% 20 pcs 12 V / 9 AH 20 pcs x 2 strings 20pcs x 3 strings 990% 1A 2A 2A 4A 273 VDC ± 1% 4A 4A 4A 12A 273 VDC ± 1% LCD / 4 1, x x (mm), x x (mm) 592 x 250 x 576 592 x 250 x 576 815 x 250 x 826 592 X 250 X 576 815 x 250 x 826 592 X 250 X 576 815 x 300 x 1000 815 x 250 x 826 (kgs) (kgs)) 83 28 164 40 164 40 234 64 0-95 % RH @ 0-40 C () 60dB @ 1 65dB @ 1 RS-232/USB 2000/2003/XP/Vista/2008, Windows 7/8, Linux, Unix, and MAC *When using internal batteries from 18-19, the unit will de-rate according to below formula: P=Prating X N/20 ***208VAC60% * L * 3 x 400 VAC (3Ph+N) 305-478 VAC (3-phase) @ 100% 190-520 VAC (3-phase) @ 50% 46~54 Hz 56~64Hz 0.99 @ 100% 6% @ 100% () 208/220/230/240VAC ± 1% () 46~54Hz 56~64Hz () 50 Hz ± 0.1 Hz 60 Hz ± 0.1 Hz 3:1 SNMP 2 % THD () 5 % THD () SNMP 4000-870-558 www.quanhan-tw.com
() () () Proline 3/3-10K (L) Proline 3/3-15K (L) Proline 3/3-20K (L) Proline 3/3-30K (L) 10000 VA / 8000 W 15000 VA / 12000 W 20000 VA / 16000 W 30000 VA / 24000 W 0.99 @ 100% 3 x 400 VAC (3Ph+N) () ± 1% 89% 89% 89% 90% 86% 88% 87% 89% 20 pcs 12 V / 9 AH 20 pcs x 2 strings 20pcs x 3 strings 990% 1A 2A 2A 4A 273 VDC ± 1% 4A 4A 4A 12A 273 VDC ± 1% LCD UPS/ 4 1, x x (mm), x x (mm) 815 x 250 x 826 592 x 250 x 826 815 x 250 x 826 592 X 250 X 826 815 x 250 x 826 592 X 250 X 826 815 x 300 x 1000 815 x 250 x 826 (kgs) (kgs) 109 38 164 40 164 40 233.5 64 0-95 % RH @ 0-40 C () 60dB @ 1 65dB @ 1 RS-232/USB Windows 2000/2003/XP/Vista/2008, Windows 7/8, Linux, Unix, and MAC SNMP Proline 3P/3P 10K/15K/20K/30K 3 x 400 VAC (3Ph+N) 305-478 VAC (3-phase) @ 100% 190-520 VAC (3-phase) @ 50% 46~54 Hz 56~64Hz 46~54Hz 56~64Hz 50 Hz ± 0.1 Hz 60 Hz ± 0.1 Hz 3:1 (.) 2 % THD () 5 % THD () SNMP * L **When using internal batteries from 18-19, the unit will de-rate according to below formula: P=Prating X N/20 ***208VAC90% * 4000-870-558 www.quanhan-tw.com
Agies 3P/3P Agies 40K 40KVA/32KW Agies 60K Agies 80K Agies 100K Agies 120K Agies 160K Agies 200K 60KVA/48KW 80KVA/64KW 100KVA/80KW 120KVA/96KW 160KVA/128KW 200KVA/160KW < 1.0% @ 100% < 2.0% @ 50% < 5.0% @ 10% 3 x 400V (3Ph + N) +15% 20% 50/60 Hz ± 5 % : PFC () 1.0 3 x 400V (3Ph + N) : ±1% : ±2% ( 100-0-100%) 50/60 Hz () ±4 % ±0.05% ±10 Hz/s < 1.5% @ 100% < 2.0% @ 50% < 6.0% @ 10% <0.5% () <1.5% () 120º ±1% () 120º ±2% (50%) 10 ms. (98 % 125% 10, 150% 60 3.2 : 1 2.8 : 1 3.2 :1 3.0 :1 0.7 inductive to 0.7 capacitive () <1% High overload, short-circuit: RMS Voltage Limit High Crest-Factor current: Peak Voltage Limit 3x400V (3Ph + N) 50/60 Hz 400% 10 150% 3 x 400V (3Ph + N) 50/60 Hz () 92.5% 93.0% 94.0% 93.0% 93.3% 92.8% 92.6%, x x (mm) 805x590x1320 () (Kg) (2x31) () () (Kg) * 180 12V 18Ah 7 565 210 230 255 255 550 550 - - - 4000-870-558 www.quanhan-tw.com
Mplus 30K Mplus 60K Mplus 90K Mplus 120K Mplus 150K Mplus 180K Mplus 210K 30KW 60KW 90KW 120KW 150KW 180KW 210KW 1 2 3 4 5 6 7 3 x 400 VAC (3Ph+N) 305 ~ 477 VAC (100% ) 208 ~ 304VAC (70% ) 50/60Hz () 40Hz ~70Hz > 0.99 (100% ) >0.98(50%) < 3% @ 100% 3 x 400 VAC (3Ph+N) () / xx xx IP RS-232/USB SNMP EMC * * ± 1% Typical () ± 2% Typical () ± 5% 50/60Hz 46Hz ~ 54Hz 56Hz ~ 64Hz 110%1, 120%10, 150%1 >150%200 1% THD () 4% THD () > 96% @ 50% > 95% @ 25% +/- 216V (12V x 36 Pcs) +/- 240V (12V x 40 Pcs) +/- 192V (12V x 38 Pcs) 2.25V/Cell 2.35V/Cell 8A 600 x 1100 x 1485 (30U) mm - 600 x 1100 x 2030 (42U) mm 0 ~ 40 0 ~ 95% IP 20 Windows 2000/2003/XP/Vista/2008/7, Linux, Unix and MAC IEC/EN 60950-1; IEC/EN 62040-1 IEC/EN 62040-2 Category C3 4000-870-558 www.quanhan-tw.com
Module UPS MPlus Module UPS PHASE 3-phase in/3-phase out 30 KW 60 KW 90 KW 120 KW 150 KW 180 KW 210 KW 1 2 3 4 5 6 7 True Double-Conversion Online Nominal Voltage 3 x 400 VAC (3Ph+N) Voltage Range 305 ~ 477 VAC @Full load; 208 ~ 304VAC@ <70% Load Nominal Frequency 50/60Hz (Auto Sensing) Frequency Range 40Hz ~70Hz Power Factor > 0.99 @ 100% Load, >0.98 @ 50% Load Harmonic Distortion (THDi) < 3% @ 100% load Nominal Voltage 3 x 400 VAC (3Ph+N) Voltage Regulation (Steady state) ± 1% Typical (balanced load) ; ± 2% Typical (unbalanced load) Voltage Regulation (Transient) ± 5% Typical Nominal Frequency 50/60Hz Frequency Range (Synchronized) 46Hz ~ 54Hz or 56Hz ~ 64Hz Overload Capability 1 hour for 110%, 10 mins for 120%,; 1 min for 150%, 20 for >150% Harmonic Distortion 1% THD (Linear Load) ; 4% THD (Non-linear Load) > 96% @ over 50% Load, > 95% @ over 25% Load Nominal Voltage +/- 216V (12V x 36 pcs) Maximum Voltage +/- 240 (12V x 40 pcs) Minimum Voltage +/- 192V (12V x 32 pcs) Float Charging Voltage 2.25V / Cell Boost Charging Voltage 2.35V / Cell Temperature Compensation Yes Maximum Charging Current 8A (User-adjustable) Medium Size, D x W x H(mm) 1100 x600 x 1485 (30U) mm - Full Size, D x W x H(mm) 1100 x600 x 2030 (42U) mm Operation Temperature 0 ~ 40 C Relative Humidity 0 ~ 95% non-condensing Altitude <1000m for Nominal power IP Class IP 20 Smart RS-232 / USB Supports Windows 2000/2003/XP/Vista/2008, Windows 7/8, Linux, Unix, and MAC Optional SNMP Power management from SNMP manager and web browser Safety IEC/EN 60950-1; IEC/EN 62040-1 EMC IEC/EN 62040-2 Category C3 * When temperature is above 30 C, the output power will be derated, 27kW @ 31 ~ 35 C and 24kW @ 36 ~ 40 C. * Note: One battery module contains 10 pcs of 12V/7Ah or 12/9Ah sealed lead acid batteries. One power module provides 30kW power capacity
Module UPS Input / Output Maintenance Bypass Breakers LCD Panel Display STS Module Includes Communication Ports Power Module Battery Module 30U Cabinet 42U Cabinet 30KW+30KW redundant 60KW+30KW redundant 60KW+30kW redundant 90kW+30kW redundant System Cabinet Selection Capacity 30KVA 60KVA 90KVA 30KVA 60KVA 90KVA 120KVA Power Module Units 1 2 3 1 2 3 4 Power Redundancy Availability Yes, 1+1 Yes, 2+1 No Yes, 1+1 Yes, 2+1 Yes, 3+1 No Built-in Battery Yes, 80pcs Yes, 120pcs Yes, 120pcs *External battery cabinet is necessary. Yes, 80pcs Yes, 120pcs Yes, 200pcs Yes, 200pcs *External battery cabinet is necessary. Capacity 30KVA 60KVA 90KVA 120KVA 150KVA 280KVA Power Module Units 1 2 3 4 5 6 Power Redundancy Availability Yes, 1+1 Yes, 2+1 Yes, 3+1 Yes, 4+1 Yes, 5+1 Yes, No Built-in Battery No External battery is depending on customer s applicatio Capacity 30KVA 60KVA 90KVA 120KVA 150KVA 180KVA 210KVA Power Module Units 1 2 3 4 5 6 7 Power Redundancy Availability Yes, 1+1 Yes, 2+1 Yes, 3+1 Yes, 4+1 Yes, 5+1 Yes, 6+1 Yes, 7+1 Built-in Battery No External battery is depending on customer s applicatio