+86-760-88758975 Page 1 of 19 Pages Report No.: 11 Test Time: 2017/11/8 20:42 Luminaire Property Luminaire Manufacturer: Luminaire Description: SMD-WANT-SS-10 Current: 0.096 A Power Factor: 0.452 Voltage: 220 V Power: 9.55 W Photometric Results CIE Class: Direct Total Rated Lamp Lumens: 782.6 lm Measurement Flux: 782.6 lm Efficiency: 100% Downward Ratio: 99% Upward Ratio: 1% Horizontal Diffuse Angle(50%): H70.6 Vertical Diffuse Angle(50%): V89.2 Luminaire Efficacy Rating (LER): 81.99 Central Intensity: 459.48 cd Max. Intensity: 518.1 cd Pos of Max. Intensity: H45 V6 S/MH(C0/C180): 1.02 S/MH(C90/C270): 1.13 Picture Of Luminaire Luminous Intensity Distribution Curve 160 170 150 140 130 120 110 100 180 170 160 150 140 130 120 110 100 90 90 129 80 80 70 259 70 60 388 60 50 518 50 40 40 30 647 30 20 10 0 10 20 Unit: cd Average Diffuse Angle(50%): 78.8 C0-C180 C90-C270 G6
+86-760-88758975 Page 2 of 19 Pages Luminous Intensity Distribution Curve 170 160 150 140 130 120 110 100 180 170 160 150 140 130 120 110 100 90 90 80 70 60 129 259 388 80 70 60 50 40 30 20 10 518 647 0 10 20 30 50 40 647 518 388 259 129 0-180 -120-60 0 60 120 180 C0-C180 C90-C270 Unit: cd
+86-760-88758975 Page 3 of 19 Pages Luminous Intensity Distribution Curve(cd/klm) 150 160 170 180 170 160 150 140 140 130 130 120 120 110 110 100 100 90 90 80 165 80 70 331 70 60 496 60 50 40 662 40 50 30 cd/klm C0-C180 C90-C270 20 10 827 0 10 20 30 η=100%
RC RW RCR 0 1 2 3 4 5 6 7 8 9 10 杭州创惠仪器有限公司 +86-760-88758975 Page 4 of 19 Pages Coefficients Of Utilization - Zonal Cavity Method 0.8 0.8 0.8 0.8 0.7 0.7 0.7 0.7 0.5 0.5 0.5 0.3 0.3 0.3 0.1 0.1 0.1 0 0.7 0.5 0.3 0.1 0.7 0.5 0.3 0.1 0.5 0.3 0.1 0.5 0.3 0.1 0.5 0.3 0.1 0 Spacing Criteria (0-180): 1.02 Spacing Criteria (90-270): 1.13 Spacing Criteria (Diagonal): 1.13 N 30 25 20 15 10 RF = 119 119 119 119 116 116 116 116 111 111 111 106 106 106 101 101 101 99 112 108 105 102 109 106 103 100 101 99 97 98 96 94 94 92 91 89 104 97 92 88 101 96 91 87 92 88 85 89 85 83 86 83 81 79 96 88 81 76 94 86 80 75 83 78 74 81 76 73 78 75 72 70 89 80 72 67 87 78 72 66 76 70 65 74 69 65 71 67 64 62 83 72 65 59 81 71 64 59 69 63 58 67 62 58 65 61 57 55 77 66 58 53 76 65 58 53 63 57 52 62 56 52 60 55 51 49 72 61 53 48 71 60 53 47 58 52 47 57 51 47 56 50 46 45 68 56 48 43 66 55 48 43 54 47 43 53 47 42 51 46 42 40 64 52 44 39 62 51 44 39 50 44 39 49 43 39 48 43 39 37 60 48 41 36 59 47 41 36 46 40 36 46 40 36 45 39 36 34 Curves of Luminaires vs Lighting Area H=2 8 7 6 Luminous Flux 5000 lm 5 Maintain Factor 0.70 4 Suspend Length 0.00m Work Height 0.80m 3 Average Lux 100 lx Reflectivity(%) Line Type Ceil Wall Floor 70 50 30 2 10 2 2 3 4 5 6 7 8 910 3 2 3 4 5 6 7 8 910 4 A(sq.m) H=10 H=12 H=7 H=5 H=3
+86-760-88758975 Page 5 of 19 Pages Isocandela (rectangle) 80 60 Vertical(Deg) 40 20 0-20 26 5278 104 130 259 389-40 -60-80 -80-60 -40-20 0 20 40 60 80 Horizontal(Deg) Imax (100%): 518 cd ( 5%): 26 cd ( 10%): 52 cd ( 15%): 78 cd ( 20%): 104 cd ( 25%): 130 cd ( 50%): 259 cd ( 75%): 389 cd (100%): 518 cd
+86-760-88758975 Page 6 of 19 Pages IsoLux Plot 5 4 3 2 3 1 Horizontal(m) 0 1 3 4 4 5 2 3 4 5 5 4 3 2 1 0 1 2 3 4 5 Vertical(m) Mounting Height: 10.0m Max Lux(100%): 5.1 lx ( 50%): 2.6 lx ( 60%): 3.1 lx ( 70%): 3.6 lx ( 80%): 4.1 lx ( 90%): 4.6 lx (100%): 5.1 lx
+86-760-88758975 Page 7 of 19 Pages Lum Limit Curve Dazzle Quality Illuminance (lx) 1.15 A 2000 1000 500 <=300 1.50 B 2000 1000 500 <=300 1.85 C 2000 1000 500 <=300 2.20 D 2000 1000 500 <=300 2.55 E 2000 1000 500 <=300 a b c d e f g h Gamma 85 75 65 a b c d e f g h 8 6 4 a/hs 3 2 55 45 6 7 8 9 1000 2 3 4 5 6 7 8 9 10000 2 3 4 C90 C270 L(cd/sq.m) Gamma 85 75 65 55 a b c d e f g h 8 6 4 a/hs 3 2 45 6 7 8 9 1000 2 3 4 5 6 7 8 9 10000 2 3 4 C0 C180 L(cd/sq.m) L(cd/sq.m) G45 G50 G55 G60 G65 G70 G75 G80 G85 C0 201 159 118 68 30 4 3 2 1 C90 218 184 152 92 65 25 5 2 0 C180 118 68 30 5 3 2 1 0 0 C270 243 183 150 101 63 23 5 2 0
+86-760-88758975 Page 8 of 19 Pages Illuminance at a Distance Dist(m) Enadir(lx) Dh/Dv_B(m) S_B(sq.m) Eav_B(lx) 1.0 459.48 1.37/1.97 2.2 137.61 2.0 114.87 2.73/3.93 8.8 34.40 3.0 51.05 4.10/5.90 19.7 15.29 4.0 28.72 5.46/7.87 35.0 8.60 5.0 18.38 6.83/9.83 54.7 5.50 6.0 12.76 8.19/11.80 78.8 3.82 7.0 9.38 9.56/13.77 107.3 2.81 8.0 7.18 10.92/15.73 140.1 2.15 10.0 4.59 13.66/19.67 218.9 1.38 Dh 12.0 3.19 16.39/23.60 315.2 0.96 Dv Beam Angle(B): H68.6 V89.0 Field Angle(F): H115.8 V133.8
+86-760-88758975 Page 9 of 19 Pages Vertical IsoLux Plot 1 230 2 3 4 Vertical Height(m) 5 6 7 8 9 10 11 0 1 2 3 4 5 6 7 8 9 10 Horizontal distance(m) Lowest(m): 1.0m Highest(m): 11.0m Max Lux: 459.5 lx ( 50%): 229.7 lx ( 60%): 275.7 lx ( 70%): 321.6 lx ( 80%): 367.6 lx ( 90%): 413.5 lx (100%): 459.5 lx
+86-760-88758975 Page 10 of 19 Pages The Average Illuminance Effective Figure Flux Out: 394.56lm 1.0m 269.42/ 459.48lx 1.37m / 1.46sq.m 2.0m 67.36/ 114.87lx 2.73m / 5.86sq.m 3.0m 29.94/ 51.05lx 4.10m / 13.18sq.m 4.0m 16.84/ 28.72lx 5.46m / 23.43sq.m 5.0m 10.78/ 18.38lx 6.83m / 36.61sq.m 6.0m 7.48/ 12.76lx 8.19m / 52.72sq.m 7.0m 5.50/ 9.38lx 9.56m / 71.76sq.m 8.0m 4.21/ 7.18lx 10.92m / 93.73sq.m 10.0m 2.69/ 4.59lx 13.66m / 146.45sq.m 12.0m 1.87/ 3.19lx 16.39m / 210.88sq.m Height Avg./Nadir. E Beam Angle:68.6 Diameter / Area
+86-760-88758975 Page 11 of 19 Pages UGR Table Reflectance: Ceiling (cavity) 0.7 0.7 0.5 0.5 0.3 0.7 0.7 0.5 0.5 0.3 Wall 0.5 0.3 0.5 0.3 0.3 0.5 0.3 0.5 0.3 0.3 Reference plane Room dimensions X=2H Y=2H 3H 4H 6H 8H 12H X=4H Y=2H 3H 4H 6H 8H 12H X=8H Y=4H 6H 8H 12H X=12H Y=4H 6H 8H Viewed crosswise Viewed endwise Variations with the observer position at spacings: S=1.0H -1.$/-1.$ -1.$/-1.$ S=1.5H -1.$/-1.$ -1.$/-1.$ S=2.0H -1.$/-1.$ -1.$/-1.$ Calculate in accordance with CIE Pub.117. The table is revised with 783lm (8log(F/F0) = -0.9).
+86-760-88758975 Page 12 of 19 Pages Utilisation Factor Table(Floor cavity) Utilisation Factors UF(F) SHR NOM = 1.00 Room Reflectance Room Index(RI) Ceiling Wall Floor 0.75 1.00 1.25 1.50 2.00 2.50 3.00 4.00 5.00 0.70 0.50 0 0.67 0.78 0.84 0.89 0.95 1.00 1.02 1.06 1.08 0.30 0.60 0.71 0.78 0.84 0.91 0.95 0.98 1.03 1.05 0 0.56 0.66 0.74 0.79 0.87 0.92 0.95 1.00 1.03 0.50 0.50 0 0.66 0.76 0.82 0.86 0.92 0.96 0.99 1.02 1.04 0.30 0.60 0.70 0.77 0.82 0.88 0.93 0.95 0.99 1.02 0 0.55 0.66 0.73 0.78 0.85 0.90 0.93 0.97 1.00 0.30 0.50 0 0.64 0.74 0.80 0.84 0.89 0.93 0.95 0.98 1.00 0.30 0.59 0.69 0.75 0.80 0.86 0.90 0.93 0.96 0.98 0 0.55 0.65 0.72 0.77 0.83 0.87 0.90 0.94 0.97 0.00 0.00 0.00 0.53 0.63 0.69 0.74 0.80 0.84 0.86 0.90 0.92 Rating:10W Photometrically tested without ceiling board. Multiply UF values by service correction factors Calculate in accordance with CIBSE Technical Memorandum NO.5 1980
+86-760-88758975 Page 13 of 19 Pages Utilisation Factor Table(Wall) Utilisation Factors UF(W) SHR NOM = 1.00 Room Reflectance Room Index(RI) Ceiling Wall Floor 0.75 1.00 1.25 1.50 2.00 2.50 3.00 4.00 5.00 0.70 0.50 0 0.85 0.68 0.56 0.48 0.37 0.31 6 0 0.16 0.30 0.71 0.58 0.49 0.43 0.34 8 4 0.19 0.15 0 0.61 0.51 0.43 0.38 0.31 6 2 0.18 0.15 0.50 0.50 0 0.82 0.65 0.53 0.46 0.35 0.33 4 0.18 0.15 0.30 0.69 0.56 0.47 0.41 0.32 7 3 0.17 0.14 0 0.60 0.49 0.42 0.37 0.30 5 1 0.17 0.14 0.30 0.50 0 0.79 0.62 0.51 0.43 0.33 7 3 0.17 0.14 0.30 0.67 0.54 0.46 0.39 0.31 5 1 0.17 0.13 0 0.59 0.48 0.41 0.36 9 4 0 0.16 0.13 0.00 0.00 0.00 0.48 0.38 0.31 6 0 0.17 0.14 0.11 0.09 Rating:10W Photometrically tested without ceiling board. Multiply UF values by service correction factors Calculate in accordance with CIBSE Technical Memorandum NO.5 1980
+86-760-88758975 Page 14 of 19 Pages Utilisation Factor Table(Ceiling cavity) Utilisation Factors UF(C) SHR NOM = 1.00 Room Reflectance Room Index(RI) Ceiling Wall Floor 0.75 1.00 1.25 1.50 2.00 2.50 3.00 4.00 5.00 0.70 0.50 0 0.16 0.17 0.18 0.19 0 0 1 2 2 0.30 0.10 0.12 0.13 0.14 0.16 0.17 0.18 0.19 0 0 0.06 0.08 0.09 0.11 0.13 0.14 0.16 0.17 0.18 0.50 0.50 0 0.15 0.16 0.17 0.18 0.19 0 0 1 1 0.30 0.10 0.11 0.13 0.14 0.15 0.17 0.17 0.19 0.19 0 0.06 0.08 0.09 0.11 0.13 0.14 0.15 0.17 0.18 0.30 0.50 0 0.15 0.16 0.17 0.17 0.18 0.19 0.19 0 0 0.30 0.10 0.11 0.12 0.14 0.15 0.16 0.17 0.18 0.19 0 0.06 0.08 0.09 0.10 0.12 0.14 0.15 0.16 0.17 0.00 0.00 0.00 0.01 0.01 0.01 0.01 0.01 0.01 0.01 0.01 0.01 Rating:10W Photometrically tested without ceiling board. Multiply UF values by service correction factors Calculate in accordance with CIBSE Technical Memorandum NO.5 1980
+86-760-88758975 Page 15 of 19 Pages Zonal Lumen Gamma Imean Zonal Flux Sum Zonal Flux Rel Zonal FluxSum Rel Zonal Flux [ ] [cd] [lm] [lm] [%] [%] 0.0-1.0 461.6 0.4 0.4 0.06 0.06 1.0-2.0 462.2 1.3 1.8 0.17 3 2.0-3.0 463.3 2.2 4.0 8 0.51 3.0-4.0 464.1 3.1 7.1 0.40 0.91 4.0-5.0 464.2 4.0 11.1 0.51 1.42 5.0-6.0 463.4 4.9 16.0 0.62 2.04 6.0-7.0 460.7 5.7 21.7 0.73 2.77 7.0-8.0 456.2 6.5 28.2 0.83 3.60 8.0-9.0 450.4 7.3 35.5 0.93 4.54 9.0-10.0 443.5 8.0 43.5 1.03 5.56 10.0-11.0 436.0 8.7 52.2 1.11 6.68 11.0-12.0 428.5 9.4 61.6 1.20 7.87 12.0-13.0 421.5 10.0 71.6 1.28 9.15 13.0-14.0 415.5 10.6 82.3 1.36 10.51 14.0-15.0 410.5 11.3 93.5 1.44 11.95 15.0-16.0 406.0 11.9 105.4 1.52 13.47 16.0-17.0 401.3 12.5 117.9 1.60 15.07 17.0-18.0 396.0 13.1 131.0 1.67 16.74 18.0-19.0 390.6 13.6 144.6 1.74 18.47 19.0-20.0 385.5 14.1 158.7 1.80 28 20.0-21.0 380.4 14.6 173.3 1.87 22.14 21.0-22.0 374.8 15.1 188.4 1.93 24.07 22.0-23.0 368.5 15.5 203.8 1.98 26.04 23.0-24.0 361.4 15.8 219.6 2.02 28.06 24.0-25.0 353.9 16.1 235.7 2.06 30.12 25.0-26.0 346.4 16.4 252.1 2.09 32.21 26.0-27.0 339.0 16.6 268.7 2.12 34.33 27.0-28.0 331.8 16.8 285.5 2.15 36.48 28.0-29.0 324.4 17.0 302.4 2.17 38.65 29.0-30.0 316.7 17.1 319.5 2.19 40.83 30.0-31.0 309.0 17.2 336.7 2.20 43.03 31.0-32.0 301.8 17.3 354.0 2.21 45.24 32.0-33.0 295.0 17.4 371.4 2.22 47.46 33.0-34.0 288.5 17.5 388.9 2.23 49.69 34.0-35.0 282.0 17.5 406.4 2.24 51.93 35.0-36.0 275.6 17.5 423.9 2.24 54.17
+86-760-88758975 Page 16 of 19 Pages Zonal Lumen (Continue 1) Gamma Imean Zonal Flux Sum Zonal Flux Rel Zonal FluxSum Rel Zonal Flux [ ] [cd] [lm] [lm] [%] [%] 36.0-37.0 268.8 17.5 441.5 2.24 56.41 37.0-38.0 261.2 17.4 458.9 2.23 58.64 38.0-39.0 252.3 17.2 476.1 2.20 60.84 39.0-40.0 242.0 16.9 493.0 2.16 63.00 40.0-41.0 232.0 16.5 509.5 2.11 65.11 41.0-42.0 222.8 16.2 525.7 2.07 67.18 42.0-43.0 214.6 15.9 541.6 2.03 69.21 43.0-44.0 206.9 15.6 557.2 2.00 71.21 44.0-45.0 199.5 15.3 572.6 1.96 73.17 45.0-46.0 192.2 15.0 587.6 1.92 75.09 46.0-47.0 184.2 14.7 602.3 1.87 76.96 47.0-48.0 175.3 14.2 616.4 1.81 78.77 48.0-49.0 165.2 13.6 630.0 1.73 80.50 49.0-50.0 154.0 12.8 642.8 1.64 82.15 50.0-51.0 143.0 12.1 654.9 1.55 83.69 51.0-52.0 133.3 11.4 666.4 1.46 85.15 52.0-53.0 124.8 10.9 677.2 1.39 86.54 53.0-54.0 117.1 10.3 687.6 1.32 87.86 54.0-55.0 110.7 9.9 697.5 1.26 89.12 55.0-56.0 104.6 9.5 706.9 1.21 90.33 56.0-57.0 97.2 8.9 715.8 1.14 91.47 57.0-58.0 87.3 8.1 723.9 1.03 92.50 58.0-59.0 76.6 7.2 731.0 0.92 93.41 59.0-60.0 67.1 6.3 737.4 0.81 94.22 60.0-61.0 59.3 5.7 743.0 0.72 94.95 61.0-62.0 53.1 5.1 748.2 0.65 95.60 62.0-63.0 47.7 4.6 752.8 0.59 96.19 63.0-64.0 42.6 4.2 757.0 0.53 96.73 64.0-65.0 38.5 3.8 760.8 0.49 97.22 65.0-66.0 34.2 3.4 764.2 0.44 97.65 66.0-67.0 28.2 2.8 767.0 0.36 98.02 67.0-68.0 21.7 2.2 769.2 8 98.30 68.0-69.0 16.9 1.7 771.0 2 98.52 69.0-70.0 14.2 1.5 772.4 0.19 98.70 70.0-71.0 11.7 1.2 773.6 0.15 98.86 71.0-72.0 8.4 0.9 774.5 0.11 98.97
+86-760-88758975 Page 17 of 19 Pages Zonal Lumen (Continue 2) Gamma Imean Zonal Flux Sum Zonal Flux Rel Zonal FluxSum Rel Zonal Flux [ ] [cd] [lm] [lm] [%] [%] 72.0-73.0 5.5 0.6 775.1 0.07 99.04 73.0-74.0 4.1 0.4 775.5 0.05 99.10 74.0-75.0 3.0 0.3 775.8 0.04 99.14 75.0-76.0 2.2 776.1 0.03 99.17 76.0-77.0 1.9 776.3 0.03 99.19 77.0-78.0 1.5 776.4 0.02 99.21 78.0-79.0 1.2 0.1 776.6 0.02 99.23 79.0-80.0 1.0 0.1 776.7 0.01 99.25 80.0-81.0 0.9 0.1 776.8 0.01 99.26 81.0-82.0 0.7 0.1 776.8 0.01 99.27 82.0-83.0 0.6 0.1 776.9 0.01 99.28 83.0-84.0 0.4 0.0 776.9 0.01 99.28 84.0-85.0 0.0 777.0 0.00 99.28 85.0-86.0 0.1 0.0 777.0 0.00 99.29 86.0-87.0 0.1 0.0 777.0 0.00 99.29 87.0-88.0 0.0 0.0 777.0 0.00 99.29 88.0-89.0 0.0 0.0 777.0 0.00 99.29 89.0-90.0 0.0 0.0 777.0 0.00 99.29 90.0-91.0 0.0 0.0 777.0 0.00 99.29 91.0-92.0 0.0 0.0 777.0 0.00 99.29 92.0-93.0 0.0 0.0 777.0 0.00 99.29 93.0-94.0 0.0 0.0 777.0 0.00 99.29 94.0-95.0 0.0 0.0 777.0 0.00 99.29 95.0-96.0 0.0 0.0 777.0 0.00 99.29 96.0-97.0 0.0 0.0 777.0 0.00 99.29 97.0-98.0 0.0 0.0 777.0 0.00 99.29 98.0-99.0 0.0 0.0 777.0 0.00 99.29 99.0-100.0 0.0 0.0 777.0 0.00 99.29 100.0-101.0 0.0 0.0 777.0 0.00 99.29 101.0-102.0 0.0 0.0 777.0 0.00 99.29 102.0-103.0 0.0 0.0 777.0 0.00 99.29 103.0-104.0 0.0 0.0 777.0 0.00 99.29 104.0-105.0 0.1 0.0 777.0 0.00 99.29 105.0-106.0 0.1 0.0 777.0 0.00 99.29 106.0-107.0 0.1 0.0 777.0 0.00 99.29 107.0-108.0 0.0 777.0 0.00 99.29
+86-760-88758975 Page 18 of 19 Pages Zonal Lumen (Continue 3) Gamma Imean Zonal Flux Sum Zonal Flux Rel Zonal FluxSum Rel Zonal Flux [ ] [cd] [lm] [lm] [%] [%] 108.0-109.0 0.0 777.1 0.00 99.30 109.0-110.0 0.0 777.1 0.00 99.30 110.0-111.0 0.0 777.1 0.00 99.30 111.0-112.0 0.0 777.1 0.00 99.30 112.0-113.0 0.0 777.1 0.00 99.31 113.0-114.0 0.0 777.2 0.00 99.31 114.0-115.0 0.3 0.0 777.2 0.00 99.31 115.0-116.0 0.4 0.0 777.2 0.00 99.32 116.0-117.0 0.4 0.0 777.3 0.00 99.32 117.0-118.0 0.4 0.0 777.3 0.01 99.33 118.0-119.0 0.5 0.1 777.4 0.01 99.33 119.0-120.0 0.6 0.1 777.4 0.01 99.34 120.0-121.0 0.6 0.1 777.5 0.01 99.35 121.0-122.0 0.7 0.1 777.5 0.01 99.36 122.0-123.0 0.8 0.1 777.6 0.01 99.37 123.0-124.0 0.8 0.1 777.7 0.01 99.38 124.0-125.0 0.9 0.1 777.8 0.01 99.39 125.0-126.0 0.9 0.1 777.8 0.01 99.40 126.0-127.0 1.0 0.1 777.9 0.01 99.41 127.0-128.0 1.0 0.1 778.0 0.01 99.42 128.0-129.0 1.1 0.1 778.1 0.01 99.43 129.0-130.0 1.1 0.1 778.2 0.01 99.44 130.0-131.0 1.2 0.1 778.3 0.01 99.46 131.0-132.0 1.2 0.1 778.4 0.01 99.47 132.0-133.0 1.3 0.1 778.5 0.01 99.48 133.0-134.0 1.3 0.1 778.6 0.01 99.50 134.0-135.0 1.4 0.1 778.7 0.01 99.51 135.0-136.0 1.4 0.1 778.8 0.01 99.52 136.0-137.0 1.4 0.1 778.9 0.01 99.54 137.0-138.0 1.5 0.1 779.0 0.01 99.55 138.0-139.0 1.5 0.1 779.2 0.01 99.56 139.0-140.0 1.6 0.1 779.3 0.01 99.58 140.0-141.0 1.6 0.1 779.4 0.01 99.59 141.0-142.0 1.7 0.1 779.5 0.01 99.61 142.0-143.0 1.7 0.1 779.6 0.01 99.62 143.0-144.0 1.8 0.1 779.7 0.01 99.64
+86-760-88758975 Page 19 of 19 Pages Zonal Lumen (Continue 4) Gamma Imean Zonal Flux Sum Zonal Flux Rel Zonal FluxSum Rel Zonal Flux [ ] [cd] [lm] [lm] [%] [%] 144.0-145.0 1.8 0.1 779.9 0.01 99.65 145.0-146.0 1.9 0.1 780.0 0.01 99.67 146.0-147.0 1.9 0.1 780.1 0.01 99.68 147.0-148.0 2.0 0.1 78 0.01 99.70 148.0-149.0 2.0 0.1 780.3 0.01 99.71 149.0-150.0 2.1 0.1 780.4 0.01 99.73 150.0-151.0 2.1 0.1 780.5 0.01 99.74 151.0-152.0 2.2 0.1 780.7 0.01 99.76 152.0-153.0 2.2 0.1 780.8 0.01 99.77 153.0-154.0 2.3 0.1 780.9 0.01 99.79 154.0-155.0 2.3 0.1 781.0 0.01 99.80 155.0-156.0 2.4 0.1 781.1 0.01 99.81 156.0-157.0 2.4 0.1 781.2 0.01 99.83 157.0-158.0 2.5 0.1 781.3 0.01 99.84 158.0-159.0 2.5 0.1 781.4 0.01 99.85 159.0-160.0 2.5 0.1 781.5 0.01 99.87 160.0-161.0 2.6 0.1 781.6 0.01 99.88 161.0-162.0 2.6 0.1 781.7 0.01 99.89 162.0-163.0 2.7 0.1 781.8 0.01 99.90 163.0-164.0 2.7 0.1 781.9 0.01 99.91 164.0-165.0 2.7 0.1 781.9 0.01 99.92 165.0-166.0 2.8 0.1 782.0 0.01 99.93 166.0-167.0 2.8 0.1 782.1 0.01 99.94 167.0-168.0 2.8 0.1 782.2 0.01 99.95 168.0-169.0 2.9 0.1 782.2 0.01 99.96 169.0-170.0 2.9 0.1 782.3 0.01 99.96 170.0-171.0 2.9 0.1 782.3 0.01 99.97 171.0-172.0 2.9 0.0 782.4 0.01 99.98 172.0-173.0 2.9 0.0 782.4 0.01 99.98 173.0-174.0 3.0 0.0 782.5 0.00 99.99 174.0-175.0 3.0 0.0 782.5 0.00 99.99 175.0-176.0 3.0 0.0 782.5 0.00 99.99 176.0-177.0 3.0 0.0 782.5 0.00 100.00 177.0-178.0 3.0 0.0 782.6 0.00 100.00 178.0-179.0 3.0 0.0 782.6 0.00 100.00 179.0-180.0 3.0 0.0 782.6 0.00 100.00