Page: 1 of 9 Date: July 10, 2008 KORENIX TECHNOLOGY CO., LTD. 9 F, NO. 100-1, MING-CHUAN RD., SHIN TIEN CITY, TAIPEI, TAIWAN The following merchandise was submitted and identified by the vendor as: Product Description: JetNet PoE Switch Style/ Item No.: JetNet 3706/ No.1; JetNet 3706f-m/ No.1; JetNet 3706f-s/ No.1; JetNet 3705/ No.1; JetNet 3705f-m/ No.1; JetNet 3705f-s/ No.1; JetNet 4706/ No.1; JetNet 4706f-m/ No.1; JetNet 4706f-s/ No.1; Quantity: Total 9 pieces Testing Period: Jul. 4, 2008 to Jul. 7, 2008 We have tested the submitted sample(s) as requested and the following results were obtained: Test Required: (According to client s test specification, please see following sheets in detail.) 1. Vibration Test 2. Mechanical Shock Test Test Results: PLEASE SEE ATTACHED SHEETS Terence Hsieh Asst. Manager
Page: 2 of 9 1. Vibration Test: Test Equipment: Name Brand Model Serial No. Vibration Test System UNHOLTZ-DICKIE SAI60-H560BAC/2/ST 474 Controller Dactron LASER 7110357 Control Accelerometer PCB 353B34 121614 Lab Environmental Conditions: Ambient temperature: 25±3 Relative humidity: 55±20%RH Test Method/ Specification: Test method: Reference to IEC 60068-2-6 Sample condition: Operating Wave form: Sinusoidal Frequency: 10~150 Hz Acceleration: 10 m/s 2 Sweep rate: 1 octave/ minute Direction: X, Y, Z axes (see photo 12~17) Test duration: 20 sweeps/ axis Examine the appearance of specimen(s) by visual check and perform functional check after this test. Functional check: Connect the specimen with PC via RJ-45 port and examine the network connecting function of specimen could be work normally or not.
Page: 3 of 9 Specimen: Style/ Item No.: Quantity: JetNet 3706/ No.1; JetNet 3706f-m/ No.1; JetNet 3706f-s/ No.1; JetNet 3705/ No.1; JetNet 3705f-m/ No.1; JetNet 3705f-s/ No.1; JetNet 4706/ No.1; JetNet 4706f-m/ No.1; JetNet 4706f-s/ No.1; Total 9 pieces Test Result: Style / Item No. Check Item Appearance check (Visual check) Functional check JetNet 3706/ No.1 No visible damage Normal JetNet 3706f-m/ No.1 No visible damage Normal JetNet 3706f-s/ No.1 No visible damage Normal JetNet 3705/ No.1 No visible damage Normal JetNet 3705f-m/ No.1 No visible damage Normal JetNet 3705f-s/ No.1 No visible damage Normal JetNet 4706/ No.1 No visible damage Normal JetNet 4706f-m/ No.1 No visible damage Normal JetNet 4706f-s/ No.1 No visible damage Normal
Page: 4 of 9 2. Mechanical Shock Test: Test Equipment: Name Brand Model Serial No. Shock Test System LANSMONT 65-81 TTSII M-13418 Data Acquisition & Analysis System LANSMONT 103570-2-B 0503-73 ICP Accelerometer PCB 353B14 79713 Lab Environmental Conditions: Ambient temperature: 25±3 Relative humidity: 55±20%RH Test Method/ Specification: Test method: Reference to IEC 60068-2-27 Sample condition: Operating Pulse shape: Half sine Acceleration: 50 G Pulse duration: 11 ms Shock direction: 6 faces (±X, ±Y, ±Z axes. see photo 18~26) No. of shock: 3 shocks/ axis (total 18 shocks) Examine the appearance of specimen(s) by visual check and perform functional check after this test. Functional check: Connect the specimen with PC via RJ-45 port and examine the network connecting function of specimen could be work normally or not.
Page: 5 of 9 Specimen: Style/ Item No.: Quantity: JetNet 3706/ No.1; JetNet 3706f-m/ No.1; JetNet 3706f-s/ No.1; JetNet 3705/ No.1; JetNet 3705f-m/ No.1; JetNet 3705f-s/ No.1; JetNet 4706/ No.1; JetNet 4706f-m/ No.1; JetNet 4706f-s/ No.1; Total 9 pieces Test Result: Style / Item No. Check Item Appearance check (Visual check) Functional check JetNet 3706/ No.1 No visible damage Normal JetNet 3706f-m/ No.1 No visible damage Normal JetNet 3706f-s/ No.1 No visible damage Normal JetNet 3705/ No.1 No visible damage Normal JetNet 3705f-m/ No.1 No visible damage Normal JetNet 3705f-s/ No.1 No visible damage Normal JetNet 4706/ No.1 No visible damage Normal JetNet 4706f-m/ No.1 No visible damage Normal JetNet 4706f-s/ No.1 No visible damage Normal
Page: 6 of 9 Test Photos: 1. Appearance of specimen (JetNet 3706) 2. Appearance of specimen (JetNet 3706f-m) 3. Appearance of specimen (JetNet 3706f-s) 4. Appearance of specimen (JetNet 3705) 5. Appearance of specimen (JetNet 3705f-m)
Page: 7 of 9 Test Photos--Continued: 6. Appearance of specimen (JetNet 3705f-s) 7. Appearance of specimen (JetNet 4706) 8. Appearance of specimen (JetNet 4706f-m) 9. Appearance of specimen (JetNet 4706f-s) 10. Functional check 11. Functional check
Page: 8 of 9 Test Photos--Continued: 12. Vibration Test: X axis 13. Vibration Test: X axis 14. Vibration Test: Y axis 15. Vibration Test: Y axis 16. Vibration Test: Z axis 17. Vibration Test: Z axis
Page: 9 of 9 Test Photos--Continued: 18. Mechanical Shock Test (X axis) 19. Mechanical Shock Test (+X axis) 20. Mechanical Shock Test (-X axis) 21. Mechanical Shock Test (Y axis) 22. Mechanical Shock Test (+Y axis) 23. Mechanical Shock Test (-Y axis) 24. Mechanical Shock Test (Z axis) 25. Mechanical Shock Test (+Z axis) The End of Test Report 26. Mechanical Shock Test (-Z axis)