Quick Start Guide 4/48-Port GE Data Center Switch AS460-0T AS460-0P AS460-54T AS460-54P. Unpack the Switch and Check Contents AS460-0T AS460-0P Note: The switch can also be installed on a desktop or shelf using the included adhesive rubber foot pads.. Ground the Switch AS460-54T AS460-54P Rack mounting kit two brackets and eight screws Four adhesive foot pads Two power cords Console cable RJ-45 to DB-9 Micro-USB to RJ-45 Cable Documentation Safety and Regulatory Information, Quick Start Guide (this document) and WEEE flyer Ensure the rack on which the switch is to be mounted is properly grounded and in compliance with ETSI ETS 00 5. Verify that there is a good electrical connection to the grounding point on the rack (no paint or isolating surface treatment). For a PoE switch, attach a lug (not provided with PSU) to a # AWG minimum grounding wire (not provided with PSU), and connect it to the grounding point on the switch rear panel. Then connect the other end of the wire to rack ground. For a Non-PoE switch, attach a lug (not provided with PSU) to a #8 AWG minimum grounding wire (not provided with PSU), and connect it to the grounding point on the switch rear panel. Then connect the other end of the wire to rack ground. Note: For information on switch software, refer to www.edge-core.com. Switches with part numbers 460-54-O-******** have the Open Network Installer Environment software installer preloaded on the switch, but no switch software image. Information about compatible switch software can be found at www.edge-core.com. Caution: The earth connection must not be removed unless all supply connections have been disconnected. 4. Connect Power Warning: For indoor use only. The switch, AC power, and all connected cables are not designed for outdoor use.. Mount the Switch Install one or two universal AC PSUs in the switch. Connect an external AC power source to the PSUs. 5. Verify Switch Operation Attach the brackets to the switch. Use the screws and cage/clip nuts appropriate for the rack to secure the switch in the rack. Caution: Installing the switch in a rack requires two people. One person should position the switch in the rack, while the other secures it using the rack screws. www.edge-core.com E008-AP-R0 50000050A
Quick Start Guide Verify basic switch operation by checking the system LEDs. When operating normally, the PSU/PSU and System LEDs should all be on green. Hardware Specifications Switch Chassis 6. Perform Initial Configuration ONIE Installer Software If the network operating system (NOS) installer is located on a network server, first connect the RJ-45 Management (Mgmt) port to the network using Category 5, 5e or better twisted-pair cable. (Not required if the NOS installer is located on attached storage.) Boot the switch. Wait for the ONIE software to locate and execute the NOS installer, and then wait for the installer to load the NOS software image. Subsequent switch boots will bypass ONIE and directly run the NOS software. Note: Refer to NOS installer and NOS documentation for details on software location options and set up for ONIE. 7. Connect Network Cables Weight 440 x 50 x 44 mm (7. x.78 x.77 inches) AS460-0T: 5.6 kg (.7 lb) AS460-0P: 6.0 kg (.7 lb) AS460-54T: 5.8 kg (.86 lb) AS460-54P: 6.6 kg (4.0 lb) Temperature Operating: 0 C to 45 C ( F to F) Storage: -40 C to 70 C (-40 F to 58 F) Humidity 50 W AC PSU AC Input Power Rating Operating: 5% to 95% (non-condensing) 00-40 VAC, 50-60 Hz, -.5 A 50 W maximum 600 W AC PSU (AS460-0P) AC Input 54.5 x 0 x 40.5 mm (.5 x 8.66 x.58 inch) 00-40 VAC, 50-60 Hz, 8.5-4.5 A Power Rating 600 W maximum 54.5 x 0 x 40.5 mm (.5 x 8.66 x.58 inches) 90 W AC PSU (AS460-54P) AC Input 00-40 VAC, 50-60 Hz, -6.5 A Power Rating 90 W maximum For RJ-45 ports, connect 00-ohm Category 5, 5e or better twisted-pair cable. For AS460-0P, ports -6 can suport PoE connections up to 0 W and ports 7-4 can support UPoE connections up to 60 W. For AS460-54P, ports -40 can support PoE connections up to 0 W and ports 4-48 can support UPoE connections up to 60 W. Connect DAC cables to the SFP+/QSFP+ slots. Or first install SFP+/QSFP+ transceivers and then connect fiber optic cabling to the transceiver ports. The following transceivers are supported: 40GBASE-CR4 40GBASE-SR4 0GBASE-CR 0GBASE-SR (ET540-SR) 000BASE-SX (ET40-SX) 000BASE-LX (ET40-LX) As connections are made, check the port status LEDs to be sure the links are valid: On/Blinking Green Port has a data link. Blinking indicates network activity. On/Blinking Amber Port has a data and PoE link. Blinking indicates network activity. Regulatory Compliances Emissions Immunity Safety Taiwan RoHS 54.5 x 0 x 40.5 mm (.5 x 8.66 x.58 inches) EN 550:0+AC:0/EN 550:05+AC: 06, Class A EN 6000--:04, Class A EN 6000--:0 AS/NZS CISPR :05, Class A FCC Class A VCCI Class A CE Mark CCC GB954-008 BSMI (CNS48) KC Certification (AS460-54P Only) EN 5504:00+A:05 IEC 6000-4-//4/5/6/8/ UL (CSA. No 60950- & UL60950-) CB (IEC/EN60950-) CCC GB494-0 BSMI (CNS46-) CNS566
AS460-0T AS460-0P AS460-54T AS460-54P AS460-0T AS460-0P AS460-54T AS460-54P. www.edge-core.com
4
AS460-0T AS460-0P AS460-54T AS460-54P AS460-0T AS460-0P AS460-54T AS460-54P www.edge-core.com 5
6