MODEL 62000H SERIES 5KW / 10KW / 15KW 0 ~ 375A 0 ~ 1000V/2000V( ) : 200/220Vac, 380/400Vac, 440/480Vac 3U/15KW / &150KW / ( 10 ms ~ 99 hours) 10 100 / PROGRAMMABLE DC POWER SUPPLY MODEL 62000H SERIES USB / RS232 / RS485 GPIB / Ethernet ON / OFF (I / P) LabView Labwindows Chroma 62000H 3U 15KW DC 6 2 0 0 0 H 5KW 15KW 375A 1000V 62000H 10 150K W 450V/150A/67.5KW 100 ON/OF 62000H 16 bit 62000H U S B /RS232 / RS485 / APGGPIB Ethernet3U 62000H DC DC/DC I-V 100 I-V CE APG RS-485 RS-232 Ethernet GPIB USB Compliant
3U/15KW 62000H 3U 15KW 30V~1000V 375A~25A 3U (132.8mm) / 150KW 62000H/ / Local Front Panel Remote GPIB/USB/RS232 Master SYSTEM BUS Slave RS485/Ethernet 62150H-600S/1000SI-V I-V (MPPT) A&B SoftPanelI-V & * Solar Array Simulator A : Dynamic MPPT B : Solar Panel PC DC Input AC Power Output Solar Array Simulator UUT (PV Inverter)
62000HLIST STEP LIST100 5ms 15000s / STEP 10ms 99 hours DC/DC LIST Mode STEP Mode ISO 16750-2 ISO 16750-2
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 1. AC 2. VFD, 3. 4. ON/OFF 5. CONFIG 6. 7. 8. PROG 9. 10. 11. / & 12. RS-232 RS-485 ( ) 13. / 14. USB 15. 16. 17. / 18. 19. GPIB Ethernet (, ) 20. AC 2KW 5KW 10KW 15KW 62000H 62020H-150S : 150V/40A/2KW 62050H-40 : 40V/125A/5KW 62050H-450 : 450V/11.5A/5KW 62050H-600 : 600V/8.5A/5KW 62050H-600S : 600V/8.5A/5KW 62075H-30 : 30V/250A/7.5KW 62100H-30 : 30V/375A/11KW 62100H-40 : 40V/250A/10KW 62100H-100P*3 : 100V/250A/10KW 62100H-450 : 450V/23A/10KW 62100H-600 : 600V/17A/10KW 62100H-600S : 600V/17A/10kW 62100H-1000 : 1000V/10A/10KW 62150H-40 : 40V/375A/15KW 62150H-100P*3 : 100V/375A/15KW 62150H-450 : 450V/34A/15KW 62150H-600 : 600V/25A/15KW 62150H-600S : 600V/25A/15KW 62150H-1000 : 1000V/15A/15KW 62150H-1000S : 1000V/15A/15kW A620024 : GPIB ( ) A620025 : Ethernet ( ) A620026 : 19 *1 : 200/220Vac, 380/400Vac 440/480Vac (600V/1000V ) *2 : 200/220 Vac 440/480 Vac (30V/40V/100V/450V) *3 : 62000H-P>0.98
Program Sequences Function ISO 16750-2 Standard for Transient Test GS-95024 Standard for Transient Test Battery Charge Test -1 Model 62075H-30 62050H-40 62050H-450 62050H-600 62100H-30 62100H-40 62100H-100P Output Ratings Output 0-30V 0-40V 0-450V 0-600V 0-30V 0-40V 0-100V Output 0-250A 0-125A 0-11.5A 0-8.5A 0-375A 0-250A 0-250A Output Power 7500W 5000W 5000W 5000W 11250W 10000W 10000W Line Regulation 0.01% F.S. 0.05% F.S. Load Regulation 0.02% F.S. 0.1% F.S. Measurement Range 6V / 30V 8V / 40V 90V / 450V 120V / 600V 6V / 30V 8V / 40V 20V/100V 0.05% + 0.05% F.S. Measurement Range 50A / 250A 25A / 125A 2.3A / 11.5A 1.7A / 8.5A 75A / 375A 50A / 250A 50A / 250A 0.1% + 0.1% F.S. Output Noise & Ripple Noise (P-P) 60mV 60mV 300mV 350mV 60mV 60mV 100mV Ripple (rms) 15mV 15mV 450mV 600mV 15mV 15mV 20mV Ripple (rms) 100mA 50mA 20mA 15mA 150mA 100mA 100mA OVP Adjustment Range Range 0-110% programmable from front panel, remote digital inputs 1% of full-scale output Programming Response Time Rise Time: Full Load 6ms 8ms 60ms 60ms 6ms 8ms 20ms Rise Time: No Load 6ms 8ms 60ms 60ms 6ms 8ms 20ms Fall Time: Full Load 6ms 8ms 60ms 60ms 6ms 8ms 20ms Fall Time: 10% Load 100ms 100ms 250ms 250ms 100ms 100ms 625ms Fall Time: No Load 1s 1s 2.5s 2.5s 1s 1s 2.5s Slew Rate Control slew rate range ~ ~ ~ ~ ~ ~ ~ 5V/ms 5V/ms 7.5V/ms 10V/ms 5V/ms 5V/ms 5V/ms slew rate range 0.001A~1A/ms, Min. transition time 0.5ms Transient Response Time Recovers within 1ms to +/- 0.75% of steady-state output for a 50% to 100% or 100% to 50% load change(1a/µs) Efficiency (Typical) 0.87 0.87 0.87 0.87 0.87 0.87 0.91 Drift (30 minutes) 0.04% of Vmax 0.01% of Vmax 0.06% of Imax 0.06% of Imax Drift (8 hours) 0.02% of Vmax 0.005% of Vmax 0.04% of Imax 0.005% of Imax Temperature Coefficient 0.04% of Vmax/ C 0.005% of Vmax/ C 0.06% of Imax/ C 0.01% of Imax/ C
-2 Model 62100H-450 62100H-600 62100H-1000 62150H-40 62150H-100P 62150H-450 62150H-600 62150H-1000 Output Ratings Output 0-450V 0-600V 0-1000V 0-40V 0-100V 0-450V 0-600V 0-1000V Output 0-23A 0-17A 0-10A 0-375A 0-375A 0-34A 0-25A 0-15A Output Power 10000W 10000W 10000W 15000W 15000W 15000W 15000W 15000W Line Regulation 0.01% F.S. 0.05% F.S. Load Regulation 0.02% F.S. 0.02% F.S. 0.05% F.S. 0.02% F.S. 0.02% F.S. 0.02% F.S. 0.02% F.S. 0.05% F.S. 0.1% F.S. Measurement Range 90V/450V 120V/600V 200V/1000V 8V/40V 20V/100V 90V/450V 120V/600V 200V/1000V 0.05% + 0.05%F.S. Measurement Range 4.6A/23A 3.2A/17A 4A/10A 75A/375A 75A/375A 6.8A/34A 5A/25A 6A/15A 0.1% + 0.1%F.S. Output Noise & Ripple Noise(P-P) 300mV 350mV 2550mV 60mV 100mV 300mV 350mV 2550mV Ripple(rms) 450mV 600mV 1500mV 15mV 20mV 450mV 600mV 1500mV Ripple(rms) 40mA 30mA 180mA 150mA 100mA 60mA 45mA 270mA OVP Adjustment Range Range 0-110% programmable from front panel, remote digital inputs 1% of full-scale output Programming Response Time Rise Time:Full Load 60ms 60ms 25ms (30% F.S. 25ms (50% F.S. 8ms 20ms 60ms 60ms Rise Time:No Load 60ms 60ms 25ms 8ms 20ms 60ms 60ms 25ms Fall Time: Full Load 60ms 60ms 25ms (50% F.S. 25ms (50% F.S. 8ms 20ms 60ms 60ms Fall Time: 10% Load 250ms 250ms 120ms (10% F.S. 80ms (10% F.S. 100ms 625ms 250ms 250ms Fall Time: No Load 2.5s 2.5s 3s 1s 2.5s 2.5s 2.5s 3s Slew Rate Control slew rate range slew rate range Min. transition time Transient Response Time ~7.5V/ms ~10V/ms 0.001Vms~ 40V/ms ~5V/ms ~5V/ms 0.001A~0.1A/ms, ~7.5V/ms ~10V/ms Note *1 : Please specify GPIB or Ethernet Interface (alternative) at time of order. Note *2 : All models output power are available for 200/220Vac, 380/400Vac and 440/480Vac (600V/1000V models) line voltage. Note *3 : Call for availability. (30V/40V/100V/450V for 200/220 Vac and 440/480 Vac line voltage) 0.5ms ~40V/ms Recovers within 1ms to +/- 0.75% of steady-state output for a 50% to 100% or 100% to 50% load change(1a/µs) Efficiency (Typical) 0.87 0.87 0.85 0.87 0.92 0.87 0.87 0.87 Drift (30 minutes) 0.04% of Vmax 0.01% of Vmax 0.04% of Vmax 0.06% of Imax 0.06% of Imax 0.06% of Imax Drift (8 hours) 0.02% of Vmax 0.005% of Vmax 0.02% of Vmax 0.04% of Imax 0.005% of Imax 0.04% of Imax Temperature Coefficient 0.04% of Vmax/ C 0.005% of Vmax/ C 0.04% of Vmax/ C 0.06% of Imax/ C 0.01% of Imax/ C 0.06% of Imax/ C
Programming & Measurement Resolution (Front Panel ) 0.1mV / 1mV / 10mV / 100mV (VO < 10V / 40V / 600V / 1000V) (Front Panel) 0.1mA / 1mA / 10 ma (IO < 10A / 100A / 1000A) (Digital Interface) 0.002% of Vmax (Digital Interface) 0.002% of Imax (Analog Interface ) 0.04% of Vmax (Analog Interface ) 0.04% of Imax Remote Interface Analog programming Standard USB Standard RS-232 Standard RS485 Standard GPIB Optional Ethernet Optional System BUS(CAN) Standard for master/slave control Programming (Front Panel and Digital Interface ) 0.1% of Vmax / 0.05% of Vmax (100P models) (Front Panel and Digital Interface ) 0.3% of Imax / 0.2% of Imax (100P models) (Analog Interface) 0.2% of Vmax (Analog Interface) 0.3% of Imax GPIB Command Response Time Vout setting GPIB send command to DC source receiver <20ms Measure V & I Under GPIB command using Measure <25ms Analog Interface (I/O) and Programming inputs (I/P) 0-10Vdc / 0-5Vdc / 0-5k ohm / 4-20 ma of F.S. and monitor output (O/P) 0-10Vdc / 0-5Vdc / 4-20mA of F.S. External ON/OFF (I/P) TTL:Active Low or High(Selective) DC_ON Signal (O/P) Level by user define. ( Time delay = 1 ms at voltage slew rate of 10V/ms.) CV or CC mode Indicator (O/P) TTL Level High=CV mode ; TTL Level Low= CC mode OTP Indicator (O/P) TTL: Active Low System Fault indicator(o/p) TTL: Active Low Auxiliary power supply(o/p) Nominal supply voltage : 12Vdc / Maximum current sink capability: 10mA Safety interlock(i/p) Time accuracy: <100ms Remote inhibit(i/p) TTL: Active Low Series & Parallel Operation Master / Slave control via CAN for 10 units up to 150KW. (Series: two units / Parallel: ten units ) Auto Sequencing(List Mode) Number of program 10 Number of sequence 100 Dwell time Range 5ms - 15000S Trig. Source Manual / Auto / External Auto Sequencing (Step Mode) Start voltage 0 to Full scale End voltage 0 to Full scale Run time 10ms - 99hours Input Specification 3Ø 200~220Vac 10% VLL AC input voltage 3phase, 3 wire + ground 3Ø 380~400Vac 10% VLL 3Ø 440~480Vac 10% VLL AC frequency range 47-63 Hz Max (each phase) General Specification Maximum Remote Sense Line Drop Compensation 200/220 Vac 5KW Model : 39A 10KW Model : 69A 15KW Model : 93A 380/400 Vac 5KW Model : 22A 10KW Model : 37A/30A *5 15KW Model : 50A/30A *5 440/480 Vac 5KW Model : 19A 10KW Model : 32A 15KW Model : 44A 30V/40V model : 5% of full scale voltage per line(10% total) 100V model : 2.5% of full scale voltage per line (5% total) >100V model : 2% of full scale voltage per line (4% total) Operating Temperature Range 0 C ~ 50 C *1 Storage Temperature Range -40 C ~ +85 C Dimension (HxWxD) 132.8 x 428 x 610 mm / 5.23 x 16.85 x 24.02 inch 5KW Model : Approx. 23 kg / 50.66 lbs Weight 10KW Model : Approx. 29 kg / 63.88 lbs *2 *3 15KW Model : Approx. 35 kg / 77.09 lbs *4 Note*1 : The operating temperature range is 0 C ~ 40 C for Model 62100H-1000/62150H-1000. Note*2 : The weight is approx. 35kg/77.09 lbs for Model 62100H-1000. Note*3 : The weight is approx. 31kg/68.34 lbs for Model 62100H-100P. Note*4 : The weight is approx. 38kg/83.77 lbs for Model 62150H-100P. Note*5 : Max. input current L1,L3=17.5A & L2=30A for 62100H-100P ; Max. input current L1,L2,L3=30A for 62150H-100P.
- MODEL 62020H-150S 62050H-600S 62100H-600S 62150H-600S 62150H-1000S Output Ratings Output 0-150V 0-600V 0-600V 0-600V 0-1000V Output 0-40A 0-8.5A 0-17A 0-25A 0-15A Output Power 2000W 5000W 10000W 15000W 15000W Line Regulation +/- 0.01% F.S. +/- 0.05% F.S. Load Regulation +/- 0.05% F.S. +/- 0.1% F.S. Measurement Range 60V / 150V 120V / 600V 120V / 600V 120V / 600V 200V / 1000V 0.05% + 0.05%F.S. Measurement Range 16A / 40A 3.4A / 8.5A 6.8A / 17A 10A / 25A 6A / 15A 0.1% + 0.1%F.S. Output Noise&Ripple Noise(P-P) 450 mv 1500 mv 1500 mv 1500 mv 2550 mv Ripple(rms) 65 mv 650 mv 650 mv 650 mv 1950 mv Ripple(rms) 80 ma 150 ma 300 ma 450 ma 270mA OVP Adjustment Range Range 0-110% programmable from front panel, remote digital inputs. +/- 1% of full-scale output Programming Response Time Rise Time: 50%F.S. CC Load 10ms (6.66A loading) 30ms 30ms 30ms 25ms Rise Time: No Load 10ms 30ms 30ms 30ms 25ms Fall Time: 50%F.S. CC Load 10ms (6.66A loading) 30ms 30ms 30ms 25ms Fall Time: 10%F.S. CC Load 83ms (1.33A loading) 100ms 100ms 100ms 80ms Fall Time: No Load 300ms 1.2s 1.2s 1.2s 3s Slew Rate Control Slew Rate Range - 15V/ms - 20V/ms - 20V/ms - 20V/ms - 40V/ms Slew Rate Range Minimum Transition Time Transient response time 0.001A/ms - 1A/ms, 0.001A/ms - 0.1A/ms, 0.001A/ms - 0.1A/ms, 0.001A/ms - 0.1A/ms, 0.5ms Recovers within 1ms to +/- 0.75% of steady-state output for a 50% to 100% or 100% to 50% load change(1a/us) 0.001A/ms - 0.1A/ms, Efficiency 0.77 (Typical) 0.87 (Typical) Programming & Measurement Resolution (Front Panel) 10 mv 10 mv 10 mv 10 mv 100mV (Front Panel) 1mA 1mA 1mA 1mA 1mA (Digital Interface) 0.002% of Vmax (Digital Interface) 0.002% of Imax (Analog Interface) 0.04% of Vmax (Analog Interface) 0.04% of Imax Programming (Front Panel and Digital Interface) 0.1% of Vmax (Front Panel and Digital Interface) 0.3% of Imax (Analog Interface) 0.2% of Vmax (Analog Interface) 0.3% of Imax Parallel Operation*1 Master / Slave control via CAN for 10 units up to 150KW. (Parallel: ten units ) Auto Sequencing (I-V program) Number of program 10 Number of sequence 100 Dwell time Range 1s - 15,000S Trig. Source Manual / Auto All specifications are subject to change without notice. Please visit our website for the most up to date specifications. Note*1 : Max. Power is 20kW for 62020H-150S. Note*2 : There is parallel mode for DC power supply when the I-V curve function is enabled. 33383 66 T +886-3-327-9999 F +886-3-327-8898 www.chromaate.com info@chromaate.com ( ) 4 8F PC : 518052 T +86-755-2664-4598 F +86-755-2641-9620 www.chroma.com.cn info@chromaate.com T +86-769-8663-9376 F +86-769-8631-0896 T +86-10-5764-9600/5764-9601 F +86-10-5764-9609 T +86-23-6703-4924/6764-4839 F +86-23-6311-5376 ( ) 855 7 T +86-512-6824-5425 F +86-512-6824-0732 T +86-592-826-2055 F +86-592-518-2152 ( ) 333 40 3 T +86-21-6495-9900 F +86-21-6495-3964 62000H Series-TC-201708-pdf