(Microsoft Word DH-NVR5208\243\254DH-NVR5216-CE)

Size: px
Start display at page:

Download "(Microsoft Word DH-NVR5208\243\254DH-NVR5216-CE)"

Transcription

1 EMC TEST REPORT Authorized under Declaration of Conformity According to EN 55022:2010 EN : 2010 EN : 2007 EN : 2011 EN : 2006+A2: 2009 IEC : 2008 EN : 2008 IEC : 2010 IEC : 2012 IEC : 2005 IEC : 2008 IEC : 2009 IEC : 2004 Applicant : Zhejiang Dahua Vision Technology Co., Ltd Address : The 1st floor, building F, No.1199 Bin an road, Changhe Street, Binjiang District, Hangzhou, P.R. China Equipment : Network Video Recorder DH-NVR5204, DH-NVR5208, DH-NVR5216, DH-NVR5232, NVR5204, NVR5208,NVR5216, NVR5232, DH-NVR5204-P, Model No. : DH-NVR5208-P, DH-NVR5216-P, DH-NVR5232-P, NVR5204-P, NVR5208-P, NVR5216-P, NVR5232-P, DH-NVR5208-8P, DH-NVR5216-8P, DH-NVR5232-8P, NVR5208-8P, NVR5216-8P, NVR5232-8P The test result refers exclusively to the test presented test model / sample. Without written approval of Cerpass Technology(Suzhou) Corp. the test report shall not be reproduced except in full. This test report is only applicable to European Community. The test report must not be used by the clients to claim product certification approval by NVLAP or any agency of the Government. TEL: FAX: Page No. : 1 of 96

2 Contents CERTIFICATE OF COMPLIANCE Summary of Test Procedure and Test Results Immunity Testing Performance Criteria Definition Test Configuration of Equipment under Test Manufacturer Feature of Equipment under Test Test Software and Test Mode Description of Support Unit General Information of Test Measurement Uncertainty Test of Conducted Emission Test Limit Test Procedures Typical Test Setup Measurement equipment Test Data and Result Test Photographs Test of Radiated Emission Test Limit Test Procedures Typical test Setup Measurement equipment Test Result and Data Test Result and Data (30MHz ~ 1000MHz) Test Result and Data (1000MHz ~ 6000MHz) Test Photographs (30MHz ~ 1000MHz) Test Photographs (1000MHz ~ 6000MHz) Harmonics Test Limits of Harmonics Current Measurement Measurement equipment Test Result and Data Test Photographs Voltage Fluctuations Test Test Procedure Measurement equipment Test Result and Data Test Photographs Electrostatic Discharge Immunity Test Test Procedure Test Setup for Tests Performed in Laboratory Test Severity Levels TEL: FAX: Page No. : 2 of 96

3 8.4. Measurement equipment Test Result and Data Test Photographs Radio Frequency electromagnetic field immunity test Test Procedure Test Severity Levels Measurement equipment Test Result and Data Test Photographs Electrical Fast Transient/ Burst Immunity Test Test Procedure Test Severity Levels Measurement equipment Test Result and Data Test Photographs Surge Immunity Test Test Procedure Test Severity Level Measurement equipment Test Result and Data Test Photographs Conduction Disturbances induced by Radio-Frequency Fields Test Procedure Test Severity Levels Measurement equipment Test Result and Data Test Photographs Power Frequency Magnetic Field Immunity Tests Test Setup Test Severity Levels Measurement equipment Test Result and Data Test Photographs Voltage Dips and Voltage Interruptions Immunity Test Setup Test Conditions Measurement equipment Test Result and Data Test Photographs EUT Photographs TEL: FAX: Page No. : 3 of 96

4 History of this test report ORIGINAL. Additional attachment as following record: Attachment No. Date Description TEL: FAX: Page No. : 4 of 96

5 CERTIFICATE OF COMPLIANCE According to EN 55022:2010 EN : 2010 EN : 2007 EN : 2011 EN : 2006+A2: 2009 IEC : 2008 EN : 2008 IEC : 2010 IEC : 2012 IEC : 2005 IEC : 2008 IEC : 2009 IEC : 2004 Applicant : Zhejiang Dahua Vision Technology Co., Ltd Address : The 1st floor, building F, No.1199 Bin an road, Changhe Street, Binjiang District, Hangzhou, P.R. China Equipment : Network Video Recorder Model No. : DH-NVR5204, DH-NVR5208, DH-NVR5216, DH-NVR5232, NVR5204, NVR5208,NVR5216, NVR5232, DH-NVR5204-P, DH-NVR5208-P, DH-NVR5216-P, DH-NVR5232-P, NVR5204-P, NVR5208-P, NVR5216-P, NVR5232-P, DH-NVR5208-8P, DH-NVR5216-8P, DH-NVR5232-8P, NVR5208-8P, NVR5216-8P, NVR5232-8P I HEREBY CERTIFY THAT : The measurements shown in this test report were made in accordance with the procedures given in EUROPEAN COUNCIL DIRECTIVE 2004/108/EC. The test was carried out on Mar 04, 2013 at Cerpass Technology(Suzhou) Corp. Signature Miro Chueh/ Technical director TEL: FAX: Page No. : 5 of 96

6 1. Summary of Test Procedure and Test Results EMISSION(EN 55022:2010 / EN : 2007) Test Item Normative References Test Result Conducted Emission EN : 2010 EN : 2007 PASS Radiated Emission EN : 2010 EN : 2007 PASS Harmonics EN : 2006+A2: 2009 PASS Voltage Fluctuations EN : 2008 PASS IMMUNITY (EN : 2010) Test Item Test Spec Test Result Electrostatic Discharge Immunity Test (ESD) Radio Frequency electromagnetic field immunity test (RS) Electrical Fast Transient/ Burst Immunity Test (EFT) Surge Immunity Test Conduction Disturbances induced by Radio-Frequency Fields Power Frequency Magnetic Field Immunity Test Voltage Dips and Voltage Interruptions Immunity Test 4 kv (contact discharge) PASS 8 kv (Air discharge) MHz, 3V/m, 80%AM(1KHz) PASS AC Port: 1kV, Signal Port: 0.5 kv PASS AC Power Ports: Line to Line: 1 kv Line to earth: 2 kv PASS Signal and telecommunication port: 1 kv MHz, 3V, 80%AM(1KHz) PASS 50Hz, 1A/m PASS Voltage dips: >95% Reduction, 0.5 Durations (Cycle) PASS 30% Reduction, 25 Durations (Cycle) PASS Voltage interruptions: PASS >95% Reduction, 250 Durations (Cycle) TEL: FAX: Page No. : 6 of 96

7 IMMUNITY (EN : 2011) Test Item Test Spec Test Result Electrostatic Discharge Immunity Test (ESD) Radio Frequency electromagnetic field immunity test (RS) Electrical Fast Transient/ Burst Immunity Test (EFT) Surge Immunity Test Conduction Disturbances induced by Radio-Frequency Fields 6 kv (contact discharge) PASS 8 kv (Air discharge) MHz, 10V/m, 80%AM(1KHz) PASS AC Port: 2.0kV, Signal Port: 1.0 kv PASS AC Power Ports: line to line: 0.5,1 kv line to earth: 0.5,1,2kV PASS Signal Port: 0.5,1 kv MHz, 10V, 80%AM(1KHz) PASS Voltage Interruptions: PASS 100% Reduction, 250 Cycle Voltage Dips and Voltage Interruptions Immunity Test Voltage Dips: 60% Reduction, 10 Cycle 30% Reduction, 25 Cycle 20% Reduction, 250 Cycle PASS 2. Immunity Testing Performance Criteria Definition A. Normal performance within limits specified by the manufacture, requestor or purchaser; B. Temporary loss of function or degradation of performance which ceases after the disturbance ceases, and from which the equipment under test recovers its normal performance, without operator intervention; C. Temporary loss of function or degradation of performance, the correction of which requires operation intervention; D. Loss of function or degradation of performance which is not recoverable, owing to damage to hardware or software, or loss of data. TEL: FAX: Page No. : 7 of 96

8 3. Test Configuration of Equipment under Test 3.1. Manufacturer ZHEJIANG DAHUA TECHNOLOGY CO.,LTD. No.1187, BinAn Road, Binjiang District, Hangzhou city, Zhejiang province,china 3.2. Feature of Equipment under Test Network Video Recorder Model No.: DH-NVR5204, DH-NVR5208, DH-NVR5216, DH-NVR5232, NVR5204, NVR5208,NVR5216, NVR5232, DH-NVR5204-P, DH-NVR5208-P, DH-NVR5216-P, DH-NVR5232-P, NVR5204-P, NVR5208-P, NVR5216-P, NVR5232-P, DH-NVR5208-8P, DH-NVR5216-8P, DH-NVR5232-8P, NVR5208-8P, NVR5216-8P, NVR5232-8P Adapter1# Model No : ADS-65LSI G Input: V~ 50-60Hz 1.5A Output: 12V 5A DC Cable Non-shielding, 1.5m, with one ferrite core bonded Adapter2# Model No : FSP120-AFA DC Cable remark Input: V~ 50-60Hz 2A Output: 48V 2.5A Non-shielding, 1.5m, with one ferrite core bonded DH-NVR5232-P was selected as the test model and its data have been recorded in this report Test Software and Test Mode Test Software a During testing, the interface cables and equipment positions were varied according to Europe Standard. b Turn on the power of all equipment. C Connect the Test System and EUT. d Set the EUT working in test mode of normal operation, then test. The test modes for RE/H-F/ESD/RS/PFMF: Test Mode 1: Normal Operation The test modes for CE: Test Mode 1: Normal Operation with ADS-65LSI G Test Mode 2: Normal Operation with FSP120-AFA Test Mode 3: Normal Operation with FSP120-AFA+ ADS-65LSI G TEL: FAX: Page No. : 8 of 96

9 The test modes for ISN: Test Mode 1: Normal Operation for LAN Port(10Mbps) Test Mode 2: Normal Operation for LAN Port(100Mbps) Test Mode 3: Normal Operation for LAN Port(1000Mbps) Test Mode 4: Normal Operation for POE LAN Port(10Mbps) Test Mode 5: Normal Operation for POE LAN Port(100Mbps) The test modes for EFT/SURGE/CS/DIPS: Test Mode 1: Normal Operation with ADS-65LSI G Test Mode 2: Normal Operation with FSP120-AFA 3.4. Description of Support Unit No Device Manufacturer Model No. Description 1 Notebook PC DELL Vostro 3560 N/A 2 Notebook PC SONY PCG-71811P N/A 3 USB Keyboard DELL SK-8115 N/A 4 Camera DAHUA IP-HFW3100P N/A 5 USB Mouse DELL GOK02XYK N/A 6 LCD Monitor Lenove L2364wA N/A 7 LCD Monitor DELL 3008WFPt N/A 8 Microphone N/A N/A N/A 9 Earphone N/A N/A N/A 10 Monitor PINEER-TIMES PNT-14A N/A No Cable Quantity Description A VGA Cable 1 Shielded, 1.5m,with tow ferrite core bonded B HDMI Cable 1 Shielded, 1.5m, with tow ferrite core bonded C LAN Cable 3 Non-Shielded, 3.0m D BNC Cable 3 Non-Shielded, >3.0m E USB Cable 1 Shielded, 1.8m,with tow ferrite core bonded F USB Cable 1 Shielded, 1.2m G LAN Cable 3 Non-Shielded, >3.0m H RS232 Cable 1 Non-Shielded, 1.5m TEL: FAX: Page No. : 9 of 96

10 3.5. General Information of Test Test Site: Test Site Location : Cerpass Technology (Suzhou) Co.,Ltd No.66,Tangzhuang Road, Suzhou Industrial Park, Jiangsu , China NVLAP LAB Code : FCC Registration Number : , IC Registration Number : 7290A-1, 7290A-2 VCCI Registration Number : Frequency Range Investigated : Test Distance : T-1945 for Telecommunication Test C-2919 for Conducted emission test R-2670 for Radiated emission test below 1GHz G-227 for Radiated emission test above 1GHz Conducted Emission Test: from 150kHz to 30 MHz Radiated Emission Test: from 30 MHz to 1,000 MHz Radiated Emission Test: from 1GHz to 6GHz The test distance of radiated emission below 1GHz from antenna to EUT is 10 M. The test distance of radiated emission above 1GHz from antenna to EUT is 3 M. LABORATORY ACCREDITATION 3.6. Measurement Uncertainty Conducted Emission The measurement uncertainty is evaluated as ± 2.71 db. Radiated Emission (30MHz -1000MHz) (1G-6GHz) Horizontal The measurement uncertainty is evaluated as ±3.59 db. Vertical The measurement uncertainty is evaluated as ± 3.89 db Horizontal The measurement uncertainty is evaluated as ± 2.31 db. Vertical The measurement uncertainty is evaluated as ± 2.15 db. TEL: FAX: Page No. : 10 of 96

11 4. Test of Conducted Emission 4.1. Test Limit Conducted Emissions were measured from 150 khz to 30 MHz with a bandwidth of 9 khz and return leads of the EUT according to the methods defined in European Standard EN The EUT was placed on a nonmetallic stand in a shielded room 0.8 meters above the ground plane. The interface cables and equipment positioning were varied within limits of reasonable applications to determine the position producing maximum conducted emissions. Frequency range (MHz) Table 1 Class B Line Conducted Emission Limits: Quasi Peak Limits (db µ V) Average 0.15 to to to to to Note 1: The lower limits shall apply at the transition frequencies. Note 2: The limit decreases linearly with the logarithm of the frequency in the range 0.15 MHz to.50mhz. Table 2 - Limits of conducted common mode (asymmetric mode) disturbance at telecommunication ports in the frequency range 0.15 MHz to 30 MHz for class B equipment. Frequency range (MHz) Voltage limits db(µv) Current limits db(µa) Quasi-peak Average Quasi-peak Average 0.15 to to to to to to Note 1: The limits decrease linearly with the logarithm of the frequency in the range 0.15 to 0.5 MHz. Note 2: The current and voltage disturbance limits are derived for use with an impedance stabilization network (ISN) which presents a common mode (asymmetric mode) impedance of 150Ω to the telecommunication under test (conversion factor is 20 log10 150/1 = 44dB). TEL: FAX: Page No. : 11 of 96

12 4.2. Test Procedures a. The EUT was placed on a desk 0.8 meters height from the metal ground plane and 0.4 meter from the conducting wall of the shielding room and it was kept at least 0.8 meters from any other grounded conducting surface. b. Connect EUT to the power mains through a line impedance stabilization network (LISN). c. All the support units are connecting to the other LISN. d. The LISN provides 50 ohm coupling impedance for the measuring instrument. e. The CISPR states that a 50 ohm, 50 micro-henry LISN should be used. f. Both sides of AC line were checked for maximum conducted interference. g. The frequency range from 150 khz to 30 MHz was searched h. Set the test-receiver system to Peak Detect Function and Specified Bandwidth with Maximum Hold Mode Typical Test Setup 10cm EUT 80cm 80cm AE 80cm LISN ISN 40cm LISN 40cm TEL: FAX: Page No. : 12 of 96

13 4.4. Measurement equipment Instrument/Ancillary Manufacturer Model No. Serial No. Calibration Date Valid Date. Test Receiver R&S ESCI AMN R&S ESH2-Z Two-Line V-Network R&S ENV ISN FCC FCC-TLISN-T ISN FCC FCC-TLISN-T ISN FCC FCC-TLISN-T ISN TESEQ ISN ST Current Probe R&S EZ Passive Voltage Probe R&S ESH2-Z Attenuator R&S ESH3-Z Temperature/ Humidity Meter Zhicheng ZC1-11 CEP-TH TEL: FAX: Page No. : 13 of 96

14 4.5. Test Data and Result Test Mode : Mode 1: Normal Operation with ADS-65LSI G Product: Network Video Model: DH-NVR5232-P Recorder AC Power : AC 230V/50Hz Phase : LINE Temperature : 22 C Humidity : 50% Pressure(mbar) : 1002 Date: 2013/03/04 No. Frequency Factor Reading Level Limit Margin Detector (MHz) (db) (dbuv) (dbuv) (dbuv) (db) QP AVG QP AVG QP AVG QP AVG QP AVG QP AVG Note: Measurement Level = Reading Level + Correct Factor TEL: FAX: Page No. : 14 of 96

15 Test Mode : Mode 1: Normal Operation with ADS-65LSI G Product: Network Video Model: DH-NVR5232-P Recorder AC Power : AC 230V/50Hz Phase : NEUTRAL Temperature : 22 C Humidity : 50% Pressure(mbar) : 1002 Date: 2013/03/04 No. Frequency Factor Reading Level Limit Margin Detector (MHz) (db) (dbuv) (dbuv) (dbuv) (db) QP AVG QP AVG QP AVG QP AVG QP AVG QP AVG Note: Measurement Level = Reading Level + Correct Factor TEL: FAX: Page No. : 15 of 96

16 Test Mode : Mode 2: Normal Operation with FSP120-AFA Product: Network Video Model: DH-NVR5232-P Recorder AC Power : AC 230V/50Hz Phase : LINE Temperature : 22 C Humidity : 50% Pressure(mbar) : 1002 Date: 2013/03/04 No. Frequency Factor Reading Level Limit Margin Detector (MHz) (db) (dbuv) (dbuv) (dbuv) (db) QP AVG QP AVG QP AVG QP AVG QP AVG QP AVG Note: Measurement Level = Reading Level + Correct Factor TEL: FAX: Page No. : 16 of 96

17 Test Mode : Mode 2: Normal Operation with FSP120-AFA Product: Network Video Model: DH-NVR5232-P Recorder AC Power : AC 230V/50Hz Phase : NEUTRAL Temperature : 22 C Humidity : 50% Pressure(mbar) : 1002 Date: 2013/03/04 No. Frequency Factor Reading Level Limit Margin Detector (MHz) (db) (dbuv) (dbuv) (dbuv) (db) QP AVG QP AVG QP AVG QP AVG QP AVG QP AVG Note: Measurement Level = Reading Level + Correct Factor TEL: FAX: Page No. : 17 of 96

18 Test Mode : Mode 3: Normal Operation with FSP120-AFA+ ADS-65LSI G Product: Network Video Model: DH-NVR5232-P Recorder AC Power : AC 230V/50Hz Phase : LINE Temperature : 22 C Humidity : 50% Pressure(mbar) : 1002 Date: 2013/03/04 No. Frequency Factor Reading Level Limit Margin Detector (MHz) (db) (dbuv) (dbuv) (dbuv) (db) QP AVG QP AVG QP AVG QP AVG QP AVG QP AVG Note: Measurement Level = Reading Level + Correct Factor TEL: FAX: Page No. : 18 of 96

19 Test Mode : Mode 3: Normal Operation with FSP120-AFA+ ADS-65LSI G Product: Network Video Model: DH-NVR5232-P Recorder AC Power : AC 230V/50Hz Phase : NEUTRAL Temperature : 22 C Humidity : 50% Pressure(mbar) : 1002 Date: 2013/03/04 No. Frequency Factor Reading Level Limit Margin Detector (MHz) (db) (dbuv) (dbuv) (dbuv) (db) QP AVG QP AVG QP AVG QP AVG QP AVG QP AVG Note: Measurement Level = Reading Level + Correct Factor TEL: FAX: Page No. : 19 of 96

20 Test Mode : Mode 1: Normal Operation for LAN Port(10Mbps) Product: Network Video Recorder Model: DH-NVR5232-P AC Power : AC 230V/50Hz Phase : LAN 10Mbps Temperature : 22 C Humidity : 50% Pressure(mbar) : 1002 Date: 2013/03/04 No. Frequency Factor Reading Level Limit Margin Detector (MHz) (db) (dbuv) (dbuv) (dbuv) (db) QP AVG QP AVG QP AVG QP AVG QP AVG QP AVG Note: Measurement Level = Reading Level + Correct Factor TEL: FAX: Page No. : 20 of 96

21 Test Mode : Mode 2: Normal Operation for LAN Port(100Mbps) Product: Network Video Recorder Model: DH-NVR5232-P AC Power : AC 230V/50Hz Phase : LAN 100Mbps Temperature : 22 C Humidity : 50% Pressure(mbar) : 1002 Date: 2013/03/04 No. Frequency Factor Reading Level Limit Margin Detector (MHz) (db) (dbuv) (dbuv) (dbuv) (db) QP AVG QP AVG QP AVG QP AVG QP AVG QP AVG Note: Measurement Level = Reading Level + Correct Factor TEL: FAX: Page No. : 21 of 96

22 Test Mode : Mode 3: Normal Operation for LAN Port(1000Mbps) Product: Network Video Recorder Model: DH-NVR5232-P AC Power : AC 230V/50Hz Phase : LAN 1000Mbps Temperature : 22 C Humidity : 50% Pressure(mbar) : 1002 Date: 2013/03/04 No. Frequency Factor Reading Level Limit Margin Detector (MHz) (db) (dbuv) (dbuv) (dbuv) (db) QP AVG QP AVG QP AVG QP AVG QP AVG QP AVG Note: Measurement Level = Reading Level + Correct Factor TEL: FAX: Page No. : 22 of 96

23 Test Mode : Mode 4: Normal Operation for POE LAN Port(10Mbps) Product: Network Video Recorder Model: DH-NVR5232-P AC Power : AC 230V/50Hz Phase : LAN 10Mbps Temperature : 22 C Humidity : 50% Pressure(mbar) : 1002 Date: 2013/03/04 No. Frequency Factor Reading Level Limit Margin Detector (MHz) (db) (dbuv) (dbuv) (dbuv) (db) QP AVG QP AVG QP AVG QP AVG QP AVG QP AVG Note: Measurement Level = Reading Level + Correct Factor TEL: FAX: Page No. : 23 of 96

24 Test Mode : Mode 5: Normal Operation for POE LAN Port(100Mbps) Product: Network Video Recorder Model: DH-NVR5232-P AC Power : AC 230V/50Hz Phase : LAN 100Mbps Temperature : 22 C Humidity : 50% Pressure(mbar) : 1002 Date: 2013/03/04 No. Frequency Factor Reading Level Limit Margin Detector (MHz) (db) (dbuv) (dbuv) (dbuv) (db) QP AVG QP AVG QP AVG QP AVG QP AVG QP AVG Note: Measurement Level = Reading Level + Correct Factor Test engineer: TEL: FAX: Page No. : 24 of 96

25 4.6. Test Photographs Main Port: Mode 1 Front View Rear View TEL: FAX: Page No. : 25 of 96

26 Main Port: Mode 2 Front View Rear View TEL: FAX: Page No. : 26 of 96

27 Main Port: Mode 3 Front View Rear View TEL: FAX: Page No. : 27 of 96

28 LAN Port: 10MHz&100MHz Front View Rear View TEL: FAX: Page No. : 28 of 96

29 LAN Port: 1000MHz Front View Rear View TEL: FAX: Page No. : 29 of 96

30 5. Test of Radiated Emission 5.1. Test Limit The EUT shall meet the limits of below Table when measured at the measuring distance R in accordance with the methods described in European Standard EN If the reading on the measuring receiver shows fluctuations close to the limit, the reading shall be observed for at least 15 s at each measurement frequency; the highest reading shall be recorded, with the exception of any brief isolated high reading, which shall be ignored. Table Limits for radiated disturbance of class B ITE at a measuring distance of 10 m Frequency range Quasi-peak limits MHz db(µv/m) 30 to to NOTE 1 The lower limit shall apply at the transition frequency. NOTE 2 Additional provisions may be required for cases where interference occurs. The EUT shall meet the limits of below Table when measured in accordance with the method described in European Standard EN and the conditional testing procedure described below. Table Limits for radiated disturbance of class B ITE at a measuring distance of 3 m Frequency range GHz Average limit db(µv/m) 1 to to NOTE The lower limit applies at the transition frequency. Peak limits db(µv/m) Conditional testing procedure: The highest internal source of an EUT is defined as the highest frequency generated or used within the EUT or on which the EUT operates or tunes. If the highest frequency of the internal sources of the EUT is less than 108 MHz, the measurement shall only be made up to 1 GHz. If the highest frequency of the internal sources of the EUT is between 108 MHz and 500 MHz, the measurement shall only be made up to 2 GHz. If the highest frequency of the internal sources of the EUT is between 500 MHz and 1 GHz, the measurement shall only be made up to 5 GHz. If the highest frequency of the internal sources of the EUT is above 1 GHz, the measurement shall be made up to 5 times the highest frequency or 6 GHz, whichever is less. TEL: FAX: Page No. : 30 of 96

31 5.2. Test Procedures a. The EUT was placed on a relatable table top 0.8 meter above ground. b. The EUT was set 10 meters from the interference receiving antenna which was mounted on the top of a variable height antenna tower. c. The table was rotated 360 degrees to determine the position of the highest radiation. d. The antenna is a half wave dipole and its height is varied between one meter and four meters above ground to find the maximum value of the field strength both horizontal polarization and vertical polarization of the antenna are set to make the measurement. e. For each suspected emission the EUT was arranged to its worst case and then tune the antenna tower (from 1 M to 4 M) and turn table (from 0 degree to 360 degrees) to find the maximum reading. f. Set the test-receiver system to Peak Detect Function and specified bandwidth with Maximum Hold Mode. TEL: FAX: Page No. : 31 of 96

32 5.3. Typical test Setup Below 1GHz Test Setup Above 1GHz Test Setup TEL: FAX: Page No. : 32 of 96

33 5.4. Measurement equipment Instrument/Ancillary Manufacturer Model No. Serial No. Calibration Date Valid Date. EMI Test Receiver R&S ESCI Preamplifier Agilent 87405B My Preamplifier Agilent 8449B 3008A Ultra Broadband Antenna Broad-Band Horn Antenna R&S HL Schwarzbeck BBHA9120D 9120D Spectrum Analyzer R&S FSP Temperature/ Humidity Meter Zhicheng ZC1-11 CEP-TH TEL: FAX: Page No. : 33 of 96

34 5.5. Test Result and Data 5.6. Test Result and Data (30MHz ~ 1000MHz) Test Mode : Mode 1: Normal Operation Product: Network Video Recorder Model: DH-NVR5232-P AC Power : AC 230V/50Hz Ant. Polarization: Horizontal Temp : 23 Humidity : 52% Pressure(mbar) : 1002 Date : 2013/03/04 No. Frequency (MHz) Factor (db/m) Reading (dbuv) Level (dbuv/m) Limit (dbuv/m) Margin (db) Det. Height (cm) Azimuth (deg) QP QP QP QP QP QP Note: Measurement Level = Reading Level + Correct Factor TEL: FAX: Page No. : 34 of 96

35 Test Mode : Mode 1: Normal Operation Product: Network Video Recorder Model: DH-NVR5232-P AC Power : AC 230V/50Hz Ant. Polarization: Vertical Temp : 23 Humidity : 52% Pressure(mbar) : 1002 Date : 2013/03/04 No. Frequency (MHz) Factor (db/m) Reading (dbuv) Level (dbuv/m) Limit (dbuv/m) Margin (db) Det. Height (cm) Azimuth (deg) QP QP QP QP QP QP Note: Measurement Level = Reading Level + Correct Factor TEL: FAX: Page No. : 35 of 96

36 5.7. Test Result and Data (1000MHz ~ 6000MHz) Test Mode : Mode 1: Normal Operation Product: Network Video Recorder Model: DH-NVR5232-P AC Power : AC 230V/50Hz Ant. Polarization: Horizontal Temp : 23 Humidity : 52% Pressure(mbar) : 1002 Date : 2013/03/04 No. Frequency (MHz) Factor (db/m) Reading (dbuv) Level (dbuv/m) Limit (dbuv/m) Margin (db) Det. Height (cm) Azimuth (deg) peak AVG peak AVG peak AVG peak AVG peak AVG peak AVG Note: Measurement Level = Reading Level + Correct Factor TEL: FAX: Page No. : 36 of 96

37 Test Mode : Mode 1: Normal Operation Product: Network Video Recorder Model: DH-NVR5232-P AC Power : AC 230V/50Hz Ant. Polarization: Vertical Temp : 23 Humidity : 52% Pressure(mbar) : 1002 Date : 2013/03/04 No. Frequency (MHz) Factor (db/m) Reading (dbuv) Level (dbuv/m) Limit (dbuv/m) Margin (db) Det. Height (cm) Azimuth (deg) peak AVG peak AVG peak AVG peak AVG peak AVG peak AVG Note: Measurement Level = Reading Level + Correct Factor Test engineer: TEL: FAX: Page No. : 37 of 96

38 5.8. Test Photographs (30MHz ~ 1000MHz) Front View Rear View TEL: FAX: Page No. : 38 of 96

39 5.9. Test Photographs (1000MHz ~ 6000MHz) Front View Rear View TEL: FAX: Page No. : 39 of 96

40 6. Harmonics Test 6.1. Limits of Harmonics Current Measurement Limits for Class A equipment Limits for Class D equipment Harmonics Order n Max. Permissible harmonics current A Harmonics Order n Max. Permissible harmonics current per watt ma/w Max. Permissible harmonics current A Odd harmonics <=n<= /n Even harmonics Odd Harmonics only <=n<= /n 0.15 x15/n <=n<= /n 6.2. Measurement equipment Calibration Instrument/Ancillary Manufacturer Model No. Serial No. Valid Date. Date EMC Emission Tester EMCPARTNE Harmonics R Temperature/ Zhicheng ZC1-11 CEP-TH Humidity Meter TEL: FAX: Page No. : 40 of 96

41 6.3. Test Result and Data Basic Standard : EN Final Test Result : PASS Test Mode : Mode 1: Normal Operation Equipment : Network Video Recorder Model No. : DH-NVR5232-P Temperature : 22 Humidity : 50 % Atmospheric Pressure : 100 kpa Test Data : Mar 04, 2013 Full Bar : Actual Values Empty Bar : Maximum Values Blue : Current, Green : Voltage, Red : Failed Urms = 229.3V Freq = Range: 1 A Irms = 0.151A Ipk = 0.676A cf = P = 12.84W S = 34.71VA pf = THDi = 85.1 % THDu = 1.70 % Class A Test - Time : 15min ( 100 %) Test completed, Result: PASSED TEL: FAX: Page No. : 41 of 96

42 Order Freq. Irms Irms%L Imax Imax%L Limit [Hz] [A] [%] [A] [%] [A] EUT is PASSED if: - all Average values of the Individual Harmonic Currents (Iavg) are below 100% of the Individual Limits. - all Maximum values of the Individual Harmonic Currents (Imax) are below 150% of the Individual Limits. Test engineer: TEL: FAX: Page No. : 42 of 96

43 6.4. Test Photographs TEL: FAX: Page No. : 43 of 96

44 7. Voltage Fluctuations Test 7.1. Test Procedure The equipment shall be tested under the conditions of Clause 5. The total impedance of the test circuit, excluding the appliance under test, but including the internal impedance of the supply source, shall be equal to the reference impedance. The stability and tolerance of the reference impedance shall be adequate to ensure that the overall accuracy of ±8% is achieved during the whole assessment procedure Measurement equipment Calibration Instrument/Ancillary Manufacturer Model No. Serial No. Valid Date. Date EMC Emission Tester EMCPARTNE Harmonics R Temperature/ Zhicheng ZC1-11 CEP-TH Humidity Meter TEL: FAX: Page No. : 44 of 96

45 7.3. Test Result and Data Basic Standard : EN Final Test Result : PASS Test Mode : Mode 1: Normal Operation Equipment : Network Video Recorder Model No. : DH-NVR5232-P Temperature : 22 Humidity : 50 % Atmospheric Pressure : 100 kpa Test Data : Mar 05,2013 Full Bar : Actual Values Empty Bar : Maximum Values Circles : Average Values Blue : Current, Green : Voltage, Red : Failed TEL: FAX: Page No. : 45 of 96

46 Urms = 227.9V Freq = Range: 1 A Irms = 0.150A Ipk = 0.660A cf = P = 12.79W S = 34.17VA pf = Test - Time : 1 x 10min = 10min ( 100 %) LIN (Line Impedance Network) : No LIN Limits : Plt : 0.65 Pst : 1.00 dmax : 4.00 % dc : 3.30 % dtlim: 3.30 % dt>lim: 500ms Test completed, Result: PASSED Test engineer: TEL: FAX: Page No. : 46 of 96

47 7.4. Test Photographs TEL: FAX: Page No. : 47 of 96

48 8. Electrostatic Discharge Immunity Test 8.1. Test Procedure a. In the case of air discharge testing the climatic conditions shall be within the following ranges: - ambient temperature: 15 to 35 ; - relative humidity : 30% to 60%; - atmospheric pressure : 86 KPa (860 hpa) to 106 KPa (1060 hpa). b. Test programs and software shall be chosen so as to exercise all normal modes of operation of the EUT. The use of special exercising software is encouraged, but permitted only where it can be shown that the EUT is being comprehensively exercised. c. The test voltage shall be increased from the minimum to the selected test severity level, in order to determine any threshold of failure. The final severity level should not exceed the product specification value in order to avoid damage to the equipment. d. The test shall be performed with both air discharge and contact discharge. On reselected points at least 10 single discharges (in the most sensitive polarity) shall be applied on air discharge. On reselected points at least 25 single discharges (in the most sensitive polarity) shall be applied on contact discharge. e. For the time interval between successive single discharges an initial value of one second is recommended. Longer intervals may be necessary to determine whether a system failure has occurred. f. In the case of contact discharges, the tip of the discharge electrode shall touch the EUT before the discharge switch is operated. g. In the case of painted surface covering a conducting substrate, the following procedure shall be adopted : If the coating is not declared to be an insulating coating by the equipment manufacturer, then the pointed tip of the generator shall penetrate the coating so as to make contact with the conducting substrate. Coating declared as insulating by the manufacturer shall only be submitted to the air discharge. The contact discharge test shall not be applied to such surfaces. h. In the case of air discharges, the round discharge tip of the discharge electrode shall be approached as fast as possible (without causing mechanical damage) to touch the EUT. After each discharge, the ESD generator (discharge electrode) shall be removed from the EUT. The generator is then retriggered for a new single discharge. This procedure shall be repeated until the discharges are completed. In the case of an air discharge test, the discharge switch, which is used for contact discharge, shall be closed. TEL: FAX: Page No. : 48 of 96

49 8.2. Test Setup for Tests Performed in Laboratory The test setup consists of the test generator, EUT and auxiliary instrumentation necessary to perform DIRECT and INDIRECT application of discharges to the EUT as applicable, in the follow manner : a. Contact Discharge to the conductive surfaces and to coupling plane; b. Air Discharge at insulating surfaces. The preferred test method is that of type tests performed in laboratories and the only accepted method of demonstrating conformance with this standard. The EUT was arranged as closely as possible to arrangement in final installed conditions. A ground reference plane was provided on the floor of the test site. It was a metallic sheet (copper or aluminum) of 0.25 mm, minimum thickness; other metallic may be used but they shall have at least 0.65 mm thickness. In the Exclusive Certification Corp., we provided 1 mm thickness stainless steel ground reference plane. The minimum size of the ground reference plane is 2.5 m x 2.5 m, the exact size depending on the dimensions of the EUT. It was connected to the protective grounding system. The EUT was arranged and connected according to its functional requirements. A distance of 1m minimum was provided between the EUT and the wall of the lab. and any other metallic structure. In cases where this length exceeds the length necessary to apply the discharges to the selected points, the excess length shall, where possible, be placed non-inductively off the ground reference plane and shall not come closer than 0.2m to other conductive parts in the test setup. Where the EUT is installed on a metal table, the table was connected to the reference plane via a cable with a 470k ohm resister located at each end, to prevent a build-up of charge. The test setup was consist a wooden table, 0.8m high, standing on the ground reference plane. A HCP, 1.6 m x 0.8 m, was placed on the table. The EUT and cables was isolated from the HCP by an insulating support 0.5 mm thick. The VCP size, 0.5 m x 0.5 m. TEL: FAX: Page No. : 49 of 96

50 8.3. Test Severity Levels Contact Discharge Air Discharge Level Test Voltage (KV) of Level Test Voltage (KV) of Contact discharge Air Discharge 1 ±2 1 ±2 2 ±4 2 ±4 3 ±6 3 ±8 4 ±8 4 ±15 X Specified X Specified Remark: X is an open level Measurement equipment Instrument/Ancillary Manufacturer Model No. Serial No. Calibration Date Valid Date. ESD Simulator EM Test dito V ESD Simulator Tonometer EMC PARTNER shanghaifengy un ESD DYM Dehumidifier ZEDO ZD-220LB CEP-TH-01 N/A N/A Humidifier YADU YZ-DS251C CEP-TH-02 N/A N/A Temperature/ Humidity Meter feiyan N/A TEL: FAX: Page No. : 50 of 96

51 8.5. Test Result and Data Basic Standard : IEC Product Standard : EN : 2011 Product Standard : EN : 2010 Equipment Model No. : Network Video Recorder : DH-NVR5232-P Final Test Result : PASS Temperature : 20 C Relative Humidity : 50% Atmospheric Pressure : 100 kpa Test Date : Mar 05, 2013 For EN 55024: 2010 Test Mode 1 Contact Discharge Air Discharge 25 times / each 10 times / each Voltage 2 kv 4 kv 6 kv 8 kv 2 kv 4 kv 8 kv 10 kv Point\Polarity HCP A A A A VCP A A A A Screw A A A A Case A A A A A A Button A A A A A A Light A A A A A A VGA Port A A A A A A RS232 Port A A A A A USB Port A A A A A A Power Port A A A A A A TEL: FAX: Page No. : 51 of 96

52 For EN : 2011 Test Voltage: 230V/50Hz Contact Discharge Air Discharge 25 times / each 10 times / each Voltage 2 kv 4 kv 6 kv 8 kv 2 kv 4 kv 8 kv 10 kv Point\Polarity HCP A A A A A A VCP A A A A A A Screw A A A A A A Case A A A A A A Button A A A A A A Light A A A A A A VGA Port A A A A A A RS232 Port A A A A A A USB Port A A A A A A Power Port A A A A A A Test Voltage: 195.5V/50Hz Contact Discharge Air Discharge 25 times / each 10 times / each Voltage 2 kv 4 kv 6 kv 8 kv 2 kv 4 kv 8 kv 10 kv Point\Polarity HCP A A A A A A VCP A A A A A A Screw A A A A A A Case A A A A A A Button A A A A A A Light A A A A A A VGA Port A A A A A A RS232 Port A A A A A A USB Port A A A A A A Power Port A A A A A A TEL: FAX: Page No. : 52 of 96

53 Test Voltage:253V/50Hz Contact Discharge Air Discharge 25 times / each 10 times / each Voltage 2 kv 4 kv 6 kv 8 kv 2 kv 4 kv 8 kv 10 kv Point\Polarity HCP A A A A A A VCP A A A A A A Screw A A A A A A Case A A A A A A Button A A A A A A Light A A A A A A VGA Port A A A A A A RS232 Port A A A A A A USB Port A A A A A A Power Port A A A A A A Test engineer: TEL: FAX: Page No. : 53 of 96

54 8.6. Test Photographs TEL: FAX: Page No. : 54 of 96

55 9. Radio Frequency electromagnetic field immunity test 9.1. Test Procedure a. The equipment to be tested is placed in the center of the enclosure on a wooden table. The equipment is then connected to power and signal leads according to pertinent installation instructions. b. The required field strength is determined by placing the field strength meter(s) on top of or directly alongside the equipment under test and monitoring the field strength meter via a remote field strength indicator outside the enclosure while adjusting the continuous-wave to the applicable antennae. c. The test is normally performed with the antenna facing the most sensitive side of the EUT. The polarization of the field generated by the bucolical antenna necessitates testing each position twice, once with the antenna positioned vertically and again with the antenna positioned horizontally. The circular polarization of the field from the log-spiral antenna makes a change of position of the antenna unnecessary. d. At each of the above conditions, the frequency range is swept MHz, pausing to adjust the R.F. signal level or to switch oscillators and antenna. The rate of sweep is in the order of 1.5*10-3 decades/s. The sensitive frequencies or frequencies of dominant interest may be discretely analyzed. TEL: FAX: Page No. : 55 of 96

56 9.2. Test Severity Levels Condition of Test Remarks 1. Field Strength 10 V/m 2. Radiated Signal AM 80% Modulated with 1kHz Pulse modulation 1Hz (0.5s ON; 0.5s OFF) 3. Scanning Frequency 80MHz MHz 4 Dwell Time 3 Seconds 5. Frequency step size f : 1% 6. The rate of Swept of Frequency 1.5 x 10-3 decades/s 9.3. Measurement equipment Instrument/Ancillary Manufacturer Model No. Serial No. Calibration Date Valid Date. Signal Generator R&S SML Power Sensor R&S NR P-Z Power Sensor R&S NRP-Z Power Meter R&S NRP Power Amplifer BONN BLWA /100/40D Istropic Electric Field Probe EST.LINDGRE N HI EMS Antenna R&S HL046E N/A N/A Temperature/ Humidity Meter feiyan N/A TEL: FAX: Page No. : 56 of 96

57 9.4. Test Result and Data Basic Standard : IEC Product Standard : EN : 2011 Product Standard : EN : 2010 Equipment : Network Video Recorder Model No. : DH-NVR5232-P Final Test Result : PASS Temperature : 23 C Relative Humidity : 52% Atmospheric Pressure : 100 kpa Test Date : Mar 05, 2013 For EN 55024: 2010 Test Mode 1 Modulation : AM 80%, 1KHz sine wave, Dwell time: 3.0 S Frequency Step Size : 1 % of preceding frequency value Frequency (MHz) Antenna Polarization face Field strength (V/m) Result 80~1000 Vertical Front 3 V/m A 80~1000 Vertical Rear 3 V/m A 80~1000 Vertical Left 3 V/m A 80~1000 Vertical Right 3 V/m A 80~1000 Horizontal Front 3 V/m A 80~1000 Horizontal Rear 3 V/m A 80~1000 Horizontal Left 3 V/m A 80~1000 Horizontal Right 3 V/m A TEL: FAX: Page No. : 57 of 96

58 For EN : 2011 Test Voltage: 230V/50Hz Test Mode 1: Normal Operation Modulation : AM 80%, 1KHz sine wave, Dwell time: 3.0 S Frequency Step Size : 1 % of preceding frequency value Frequency (MHz) Antenna Polarization face Field strength (V/m) Result 80~2700 Horizontal &Vertical Front 10 V/m A 80~2700 Horizontal &Vertical Rear 10 V/m A 80~2700 Horizontal &Vertical Left 10 V/m A 80~2700 Horizontal &Vertical Right 10 V/m A Test Voltage: 195.5V/50Hz Test Mode 1: Normal Operation Modulation : AM 80%, 1KHz sine wave, Dwell time: 3.0 S Frequency Step Size : 1 % of preceding frequency value Frequency (MHz) Antenna Polarization face Field strength (V/m) Result 80~2700 Horizontal &Vertical Front 10 V/m A 80~2700 Horizontal &Vertical Rear 10 V/m A 80~2700 Horizontal &Vertical Left 10 V/m A 80~2700 Horizontal &Vertical Right 10 V/m A Test Voltage: 253V/50Hz Test Mode 1: Normal Operation Modulation : AM 80%, 1KHz sine wave, Dwell time: 3.0 S Frequency Step Size : 1 % of preceding frequency value Frequency (MHz) Antenna Polarization face Field strength (V/m) Result 80~2700 Horizontal &Vertical Front 10 V/m A 80~2700 Horizontal &Vertical Rear 10 V/m A 80~2700 Horizontal &Vertical Left 10 V/m A 80~2700 Horizontal &Vertical Right 10 V/m A Test engineer: TEL: FAX: Page No. : 58 of 96

59 9.5. Test Photographs TEL: FAX: Page No. : 59 of 96

60 10. Electrical Fast Transient/ Burst Immunity Test Test Procedure a. In order to minimize the effect of environmental parameters on test results, the climatic conditions when test is carrying out shall comply with the following requirements: ambient temperature: 15 to 35 ; relative humidity : 45% to 75%; Atmospheric pressure: 86 Kpa (860 hpa) to 106 Kpa (1060 hpa). b. In order to minimize the effect of environmental parameters on test results, the electromagnetic environment of the laboratory shall not influence the test results. c. The variety and diversity of equipment and systems to be tested make it difficult to establish general criteria for the evaluation of the effects of fast transients/bursts on equipment and systems. d. Test on Power Line: The EFT/B-generator was located on the GRP.. The length from the EFT/B-generator to the EUT is not exceeding 1 m. The EFT/B-generator provides the ability to apply the test voltage in a non-symmetrical condition to the power supply input terminals of the EUT. e. Test on Communication Lines The coupling clamp is composed of a clamp unit for housing the cable (length more than 3 m), and was placed on the GRP. The coupling clamp provides the ability of coupling the fast transient/bursts to the cable under test. f. The test results may be classified on the basic of the operating conditions and the functional specification of the equipment under test, according to the following performance criteria : Normal performance within the specification limits. Temporary degradation or loss of function or performance which is self-recoverable. Temporary degradation or loss of function or performance which requires operator intervention or system reset. Degradation or loss of function which is not recoverable due to damage of equipment (components). TEL: FAX: Page No. : 60 of 96

61 10.2. Test Severity Levels The following test severity levels are recommended for the fast transient/burst test : Open circuit output test voltage ± 10% Level On Power Supply On I/O signal, data and control line KV 0.25 KV KV 0.50 KV KV 1.00 KV KV 2.00 KV X Specified Specified Remark : X is an open level. The level is subject to negotiation between the user and the manufacturer or is specified by the manufacturer Measurement equipment Instrument/Ancillary Manufacturer Model No. Serial No. Calibration Date Valid Date. TRANSIENT EMCPARTNER TRA2000IN CDN EMCPARTNER CDN Coupling clamp EMCPARTNER CN-EFT Temperature/ Humidity Meter Zhicheng ZC1-11 CEP-TH TEL: FAX: Page No. : 61 of 96

62 10.4. Test Result and Data Basic Standard : IEC Product Standard : EN : 2011 Product Standard : EN 55024: 2010 Equipment Model No. : Network Video Recorder : DH-NVR5232-P Final Test Result : PASS Temperature : 21 C Relative Humidity : 51% Atmospheric Pressure : 100 kpa Test Date : Mar 05, 2013 For EN : 2010 Test Mode 1& Test Mode 2 Pulse : 5/50 ns Burst : 15m/300ms Repetition Rate: 5 khz above 2.0 kv 5 khz below and equal 2.0 kv Test time : 1 min/each condition Voltage/ Mode/ Polarity/ Result/ Phase 0.5 kv 1.0 kv L A A N A A L-N A A Power Line PE A A L-PE A A N-PE A A L-N-PE A A Signal Line RJ 45 A A TEL: FAX: Page No. : 62 of 96

63 For EN : 2011 Test Mode 1& Test Mode 2 Test Voltage:230V/50Hz Test Mode 1: Normal Operation Pulse : 5/50 ns Burst : 15m/300ms Test time : 1 min/each condition Voltage/ Mode/ Polarity/ Result/ Phase Repetition Rate: 5 khz /100 khz above 2.0 kv 1.0 kv 2.0 kv L A A N A A L-N A A Power Line PE A A L-PE A A N-PE A A L-N-PE A A Signal Line RJ 45 A A Test Mode 1& Test Mode 2 Test Voltage:195.5V/50Hz Test Mode 1: Normal Operation Pulse : 5/50 ns Burst : 15m/300ms Test time : 1 min/each condition Voltage/ Mode/ Polarity/ Result/ Phase Repetition Rate: 5 khz /100 khz above 2.0 kv 1.0 kv 2.0 kv L A A N A A L-N A A Power Line PE A A L-PE A A N-PE A A L-N-PE A A Signal Line RJ 45 A A TEL: FAX: Page No. : 63 of 96

64 Test Mode 1& Test Mode 2 Test Voltage:253V/50Hz Test Mode 1: Normal Operation Pulse : 5/50 ns Burst : 15m/300ms Test time : 1 min/each condition Voltage/ Mode/ Polarity/ Result/ Phase Power Line Repetition Rate: 5 khz /100 khz above 2.0 kv 1 kv 2.0 kv L A A N A A L-N A A PE A A L-PE A A N-PE A A L-N-PE A A Signal Line RJ 45 A A Test engineer: TEL: FAX: Page No. : 64 of 96

65 10.5. Test Photographs Main Port LAN Port TEL: FAX: Page No. : 65 of 96

66 POE LAN Port TEL: FAX: Page No. : 66 of 96

67 11. Surge Immunity Test Test Procedure a. Climatic conditions The climatic conditions shall comply with the following requirements : ambient temperature : 15 to 35 relative humidity : 10 % to 75 % atmospheric pressure : 86 kpa to 106 kpa ( 860 hpa to 1060 hpa ) b. Electromagnetic conditions the electromagnetic environment of the laboratory shall not influence the test results. c. The test shall be performed according the test plan that shall specify the test set-up with generator and other equipment utilized; test level ( voltage/current ); generator source impedance; internal or external generator trigger; number of tests : at least five positive and five negative at the selected points; repetition rate : maximum 1/min. inputs and outputs to be tested; representative operating conditions of the EUT; sequence of application of the surge to the circuit; phase angle in the case of AC. power supply; actual installation conditions, for example : AC : neutral earthed, DC : ( + ) or ( - ) earthed to simulated the actual earthing conditions. d. If not otherwise specified the surges have to be applied synchronized to the voltage phase at the zero-crossing and the peak value of the AC. voltage wave ( positive and negative ). e. The surges have to be applied line to line and line(s) and earth. When testing line to earth, the test voltage has to be applied successively between each of the lines and earth, if there is no other specification. f. The test procedure shall also consider the non-linear current-voltage characteristics of the equipment under test. Therefore the test voltage has to be increased by steps up to the test level specified in the product standard or test plan. g. All lower levels including the selected test level shall be satisfied. For testing the secondary protection, the output voltage of the generator shall be increased up to the worst-case voltage breakdown level ( let-through level ) of the primary protection. h. If the actual operating signal sources are not available, that may be simulated. Under no circumstances may the test level exceed the product specification. The test shall be carried out according to a test plan. i. To find all critical points of the duty cycle of the equipment, a sufficient number of positive and negative test pulses shall be applied. For acceptance test previously unstressed equipment shall be used to the protection devices shall be replaced. TEL: FAX: Page No. : 67 of 96

68 11.2. Test Severity Level Level Open-circuit test voltage, ± 10%, KV X Specified NOTE: X is an open class. This level can be specified in the product specification Measurement equipment Instrument/Ancillary Manufacturer Model No. Serial No. Calibration Date Valid Date. TRANSIENT EMCPARTNER TRA2000IN CDN EMCPARTNER CDN-UTP CDN EMCPARTNER CDN Temperature/ Humidity Meter Zhicheng ZC1-11 CEP-TH TEL: FAX: Page No. : 68 of 96

69 11.4. Test Result and Data Basic Standard : IEC Product Standard : EN : 2011 Product Standard : EN : 2010 Equipment : Network Video Recorder Model No. : DH-NVR5232-P Final Test Result : PASS Temperature : 21 C Relative Humidity : 51% Atmospheric Pressure : 100 kpa Test Date : Mar 05, 2013 For EN 55024: 2010 Power Port Test Mode 1& Test Mode 2 Waveform : 1.2/50µs(8/20µs) Repetition rate : 60 sec Time : 20 time/each condition /Phase Voltage / Mode / Polarity / Result /1.0 kv L-N + A A A A - A A A A 0.5/1.0/2.0kV L-PE N-PE + A A A A - A A A A + A A A A - A A A A Waveform : 10/700µs Repetition rate : 60 sec Time : 5 time/each condition Voltage 0.5 kv 1 kv Mode / Polarity / Result RJ45 B B B B TEL: FAX: Page No. : 69 of 96

70 For EN : 2011 Power Port Test Mode 1& Test Mode 2 Test Voltage:230V/50Hz Test Mode 1 Waveform : 1.2/50µs(8/20µs) Repetition rate : 60 sec Time : 20 time/each condition /Phase Voltage / Mode / Polarity / Result /1.0 kv L-N + A A A A - A A A A 0.5/1.0/2.0kV L-PE N-PE + A A A A - A A A A + A A A A - A A A A Waveform : 1.2/50µs(8/20µs) Repetition rate : 60 sec Time : 5 time/each condition Voltage 0.5 kv 1 kv Mode / Polarity / Result RJ45 B B B B Waveform : 10/700µs Repetition rate : 60 sec Time : 5 time/each condition Voltage 0.5 kv 1 kv Mode / Polarity / Result RJ45 B B B B TEL: FAX: Page No. : 70 of 96

71 Power Port Test Mode 1& Test Mode 2 Test Voltage:195.5V/50Hz Test Mode 1 Waveform : 1.2/50µs(8/20µs) Repetition rate : 60 sec Time : 20 time/each condition /Phase Voltage / Mode / Polarity / Result /1.0 kv L-N + A A A A - A A A A 0.5/1.0/2.0kV L-PE N-PE + A A A A - A A A A + A A A A - A A A A Waveform : 1.2/50µs(8/20µs) Repetition rate : 60 sec Time : 5 time/each condition Voltage 0.5 kv 1 kv Mode / Polarity / Result RJ45 B B B B Waveform : 10/700µs Repetition rate : 60 sec Time : 5 time/each condition Voltage 0.5 kv 1 kv Mode / Polarity / Result RJ45 B B B B TEL: FAX: Page No. : 71 of 96

72 Power Port Test Mode 1& Test Mode 2 Test Voltage:253V/50Hz Test Mode 1 Waveform : 10/700µs Repetition rate : 60 sec Time : 20 time/each condition /Phase Voltage / Mode / Polarity / Result /1.0 kv L-N + A A A A - A A A A 0.5/1.0/2.0kV L-PE N-PE + A A A A - A A A A + A A A A - A A A A Waveform : 1.2/50µs(8/20µs) Repetition rate : 60 sec Time : 5 time/each condition Voltage 0.5 kv 1 kv Mode / Polarity / Result RJ45 B B B B Waveform : 10/700µs Repetition rate : 60 sec Time : 5 time/each condition Voltage 0.5 kv 1 kv Mode / Polarity / Result RJ45 B B B B Test engineer: TEL: FAX: Page No. : 72 of 96

73 11.5. Test Photographs Main Port LAN Port TEL: FAX: Page No. : 73 of 96

74 POE LAN Port TEL: FAX: Page No. : 74 of 96

75 12. Conduction Disturbances induced by Radio-Frequency Fields Test Procedure a. The EUT shall be operated within its intended climatic conditions. The temperature and relative humidity should be recorded. b. This test method test can be performed without using a sell shielded enclosure. This is because the disturbance levels applied and the geometry of the setups are not likely to radiated a high amount of energy, especially at the lower frequencies. If under certain circumstances the radiated energy is too high, a shielded enclosure has to be used. c. The test shall be performed with the test generator connected to each of the coupling and decoupling devices in turn while the other non-excited RF-input ports of the coupling devices are terminated by a 50 ohm load resistor. d. The frequency range is swept from 150 KHz to 100 MHz, using the signal levels established during the setting process, and with the disturbance signal 80% amplitude modulated with a 1KHz sign wave, pausing to adjust the RF-signal level or to switch coupling devices as necessary. The rate of sweep shall no exceed 1.5 x 10-3 decades/s. Where the frequency is swept incrementally, the step size shall no exceed 1% of the start and thereafter 1% of the preceding frequency value. e. The dwell time at each frequency shall not be less than the time necessary for the EUT to be exercised, and able to respond. Sensitive frequencies e.g. clock frequency (ies) and harmonics or frequencies of dominant interest shall be analyzed separately. f. An alternative test procedure may be adopted, wherein the frequency range is swept incrementally, with a step size not exceeding 4% of the start ad thereafter 4% of the preceding frequency value. The test level should be at least twice the value of the specified test level. g. In cases of dispute, the test procedure using a step size not exceeding 1% of the start and thereafter 1% of preceding frequency value shall take precedence. h. Attempts should be made to fully exercise the EUT during testing, and to fully interrogate all exercise modes selected for susceptibility. i. The use of special exercising programs is recommended. j. Testing shall be performed according to a Test Plan, which shall be included in the test report. k. It may be necessary to carry out some investigatory testing in order to establish some aspects of the test plan. TEL: FAX: Page No. : 75 of 96

76 12.2. Test Severity Levels Level Voltage Level ( EMF ), 1 1 V 2 3 V 3 10 V x Specified NOTE - x is an open class. This level can be specified in the product specification Measurement equipment Instrument/Ancillary Manufacturer Model No. Serial No. Conducted immunity test system Calibration Date Valid Date. FRANKONIA CIT-10/75 102D EM Injection clamp FCC F-203I-23MM CDN FRANKONIA CDN-T2 A CDN FRANKONIA CDN-T4 A CDN FRANKONIA CDN-T8 A CDN FRANKONIA CDN-M2 A CDN FRANKONIA CDN-M2+M3 A CDN FCC CDN-M5/32 A db Attenuator FRANKONIA N/A N/A Temperature/ Humidity Meter Zhicheng ZC1-11 CEP-TH TEL: FAX: Page No. : 76 of 96

77 12.4. Test Result and Data Basic Standard : IEC Product Standard : EN : 2011 Product Standard : EN : 2010 Equipment : Network Video Recorder Model No. : DH-NVR5232-P Final Test Result : PASS Temperature : 21 C Relative Humidity : 51% Atmospheric Pressure : 100 kpa Test Date : Mar 05, 2013 For EN 55024: 2010 Test Mode 1& Test Mode 2 Frequency : 0.15~80MHz, Modulation : AM 80%,1KHz sine wave, Dwell time: 2.9s Frequency Step Size : 1 % of preceding frequency value Frequency Test mode Voltage(V) Result 0.15 ~ 80MHz Power(M3) 3 A 0.15 ~ 80MHz RJ45 3 A For EN : 2011 Test Voltage:230V/50Hz Test Mode 1& Test Mode 2 Test Mode 1: Normal Operation Frequency : 0.15~100MHz, Modulation : AM 80%,1KHz sine wave, Dwell time: 2.9s Frequency Step Size : 1 % of preceding frequency value Frequency Test mode Voltage(V) Result 0.15 ~ 100MHz Power(M3) 10 A 0.15 ~ 100MHz RJ45 10 A TEL: FAX: Page No. : 77 of 96

78 Test Voltage:195.5V/50Hz Test Mode 1& Test Mode 2 Test Mode 1: Normal Operation Frequency : 0.15~100MHz, Modulation : AM 80%,1KHz sine wave, Dwell time: 2.9s Frequency Step Size : 1 % of preceding frequency value Frequency Test mode Voltage(V) Result 0.15 ~ 100MHz Power(M3) 10 A 0.15 ~ 100MHz RJ45 10 A Test Voltage:253V/50Hz Test Mode 1& Test Mode 2 Test Mode 1: Normal Operation Frequency : 0.15~100MHz, Modulation : AM 80%,1KHz sine wave, Dwell time: 2.9s Frequency Step Size : 1 % of preceding frequency value Frequency Test mode Voltage(V) Result 0.15 ~ 100MHz Power(M3) 10 A 0.15 ~ 100MHz RJ45 10 A Test engineer: TEL: FAX: Page No. : 78 of 96

79 12.5. Test Photographs Main Port LAN Port TEL: FAX: Page No. : 79 of 96

80 POE LAN Port TEL: FAX: Page No. : 80 of 96

81 13. Power Frequency Magnetic Field Immunity Tests Test Setup GPR : Ground plane C1 : Power supply circuit A : Safety earth C2 : Signal circuit S : Insulating support L : Communication line EUT : Equipment under test B : To power supply source Lc : Induction coil D : To signal source, simulator E : Earth terminal G : To the test generator Test Severity Levels Level Magnetic field strength A/m X 1) special NOTE 1 X is an open level. This level can be givenin the product specification Measurement equipment Instrument/Ancillary Manufacturer Model No. Serial No. Calibration Date Valid Date. TRANSIENT EMCPARTNER TRA2000IN H-Filed-Loop EMCPARTNER MF Temperature/ Humidity Meter Zhicheng ZC1-11 CEP-TH TEL: FAX: Page No. : 81 of 96

82 13.4. Test Result and Data Basic Standard : IEC Product Standard : EN : 2010 Equipment : Network Video Recorder Model No. : DH-NVR5232-P Final Test Result : PASS Temperature : 21 C Relative Humidity : 51 % Atmospheric Pressure : 100 kpa Test Date : Mar 05, 2013 Power Frequency Magnetic Field : 50 Hz, 1 A/m Coil Orientation Testing duration Results X-axis 1.0 Min A Y-axis 1.0 Min A Z-axis 1.0 Min A Test engineer: TEL: FAX: Page No. : 82 of 96

83 13.5. Test Photographs TEL: FAX: Page No. : 83 of 96

84 14. Voltage Dips and Voltage Interruptions Immunity Test Setup Test Conditions 1. Source voltage and frequency : 230V / 50Hz, Single phase. 2. Test of interval : 10 sec. 3. Level and duration : Sequence of 3 dips/interrupts. 4. Voltage rise (and fall) time : 1 5 µs. 5. Test severity : Voltage dips and Interrupt reduction (%) Test Duration (period) >95% % 25 >95% 0.5 Item Environmental Units Test Performance Phenomena Specification Criteria Input AC Power Ports Voltage Dips % Reduction 20 period 250 % Reduction 30 period 25 % Reduction 60 period 10 Voltage Interruptions % Reduction 100 period Measurement equipment Instrument/Ancillary Manufacturer Model No. Serial No. Calibration Date Valid Date. TRANSIENT EMCPARTNER TRA2000IN Temperature/ Humidity Meter Zhicheng ZC1-11 CEP-TH TEL: FAX: Page No. : 84 of 96

85 14.3. Test Result and Data Basic Standard : IEC Product Standard : EN : 2011 Product Standard : EN : 2010 Equipment Model No. Final Test Result : Network Video Recorder : DH-NVR5232-P : PASS Temperature : 21 C Relative Humidity : 51% Atmospheric Pressure : 100 kpa Test Date : Mar 05, 2013 For EN 55024: 2010 Mode 1 Test Voltage: 230V/50Hz Test Mode : Mode 1: Normal Operation Interval(s) : 10s Times : 3 Test mode Test level reduction % Durations (period / ms ) Phase / Result Voltage interrupt ions Voltage dips >95% 250 C C C C C C C C 30% 25 A A A A A A A A >95% 0.5 A A A A A A A A Mode 2 Test Voltage: 230V/50Hz Test Mode : Mode 1: Normal Operation Interval(s) : 10s Times : 3 Test level Durations Test reduction (period / mode % ms ) Phase / Result Voltage interrupt ions Voltage dips >95% 250 C C C C C C C C 30% 25 A A A A A A A A >95% 0.5 A A A A A A A A TEL: FAX: Page No. : 85 of 96

86 For EN : 2011 Test Voltage: 230V/50Hz Voltage(UT): AC 230 V 50 Hz Interval(s) : 10s Times : 3 Test mod Voltage interruptions Durations Phase / Result Test level (period / UT % ms ) 100% 250 C C C C C C C C 20% 250 C C C C C C C C Voltage dips 30% 25 A A A A A A A A 60% 10 A A A A A A A A Test Voltage: 195.5V/50Hz Voltage(UT): AC 230 V 50 Hz Interval(s) : 10s Times : 3 Test mod Voltage interruptions Durations Phase / Result Test level (period / UT % ms ) 100% 250 C C C C C C C C 20% 250 C C C C C C C C Voltage dips 30% 25 A A A A A A A A 60% 10 A A A A A A A A TEL: FAX: Page No. : 86 of 96

87 Test Voltage: 253V/50Hz Voltage(UT): AC 230 V 50 Hz Interval(s) : 10s Times : 3 Test mod Voltage interruptions Durations Phase / Result Test level (period / UT % ms ) 100% 250 C C C C C C C C 20% 250 C C C C C C C C Voltage dips 30% 25 A A A A A A A A 60% 10 A A A A A A A A Test engineer: TEL: FAX: Page No. : 87 of 96

88 14.4. Test Photographs TEL: FAX: Page No. : 88 of 96

89 15. EUT Photographs 1) EUT Photo 2) EUT Photo TEL: FAX: Page No. : 89 of 96

90 3) EUT Photo 4) EUT Photo TEL: FAX: Page No. : 90 of 96

91 5) EUT Photo 6) EUT Photo TEL: FAX: Page No. : 91 of 96

92 7) EUT Photo 8) EUT Photo (Adapter 1#) TEL: FAX: Page No. : 92 of 96

93 9) EUT Photo (Adapter 1#) 10) EUT Photo (Adapter 1#) TEL: FAX: Page No. : 93 of 96

94 11) EUT Photo (Adapter 1#) 12) EUT Photo (Adapter 2#) TEL: FAX: Page No. : 94 of 96

95 13) EUT Photo (Adapter 2#) 14) EUT Photo (Adapter 2#) TEL: FAX: Page No. : 95 of 96

96 15) EUT Photo (Adapter 2#) TEL: FAX: Page No. : 96 of 96

untitled

untitled 索 1. 錄... 3 2.... 4 2.1... 4 2.2 ( 異 )... 5 2.3 輻... 6 2.4 量 不 度... 7 3.... 8 3.1... 8 3.2 輻 (30M~1GHZ)... 8 3.3 輻 (1GHZ~6GHZ)... 9 4.... 10 4.1... 10 4.2... 10 4.3 輻 (30MHZ-1GHZ)... 10 4.4 輻 (1GHZ-6GHZ)...

More information

HCD0174_2008

HCD0174_2008 Reliability Laboratory Page: 1 of 5 Date: December 23, 2008 WINMATE COMMUNICATION INC. 9 F, NO. 111-6, SHING-DE RD., SAN-CHUNG CITY, TAIPEI, TAIWAN, R.O.C. The following merchandise was submitted and identified

More information

HC70245_2008

HC70245_2008 Reliability Laboratory Page: 1 of 6 Date: September 5, 2008 WINMATE COMMUNICATION INC. 9 F, NO. 111-6, SHING-DE RD., SAN-CHUNG CITY, TAIPEI, TAIWAN, R.O.C. The following merchandise was submitted and identified

More information

untitled

untitled : TE251532 ( ) N7510, NDL-2755T CNS 13438 95 ( ) (SL2-IN/R1/R2/A1-E-0012) 101 11 22 102 12 12 01 ...iii...1 1....2 1.1...2 1.2...2 1.3...3 1.4...4 2....5 2.1...5 2.2...6 2.3...7 3....8 4....9 4.1...9 4.2...9

More information

Microsoft Word - HC20138_2010.doc

Microsoft Word - HC20138_2010.doc Page: 1 of 7 Date: April 26, 2010 WINMATE COMMUNICATION INC. 9 F, NO. 111-6, SHING-DE RD., SAN-CHUNG CITY, TAIPEI, TAIWAN, R.O.C. The following merchandise was submitted and identified by the vendor as:

More information

HC50246_2009

HC50246_2009 Page: 1 of 7 Date: June 2, 2009 WINMATE COMMUNICATION INC. 9 F, NO. 111-6, SHING-DE RD., SAN-CHUNG CITY, TAIPEI, TAIWAN, R.O.C. The following merchandise was submitted and identified by the vendor as:

More information

HC70044_2008

HC70044_2008 Page: 1 of 9 Date: July 10, 2008 KORENIX TECHNOLOGY CO., LTD. 9 F, NO. 100-1, MING-CHUAN RD., SHIN TIEN CITY, TAIPEI, TAIWAN The following merchandise was submitted and identified by the vendor as: Product

More information

HC20093A_2008

HC20093A_2008 Reliability Laboratory Page: 1 of 6 Date: March 5, 2008 KORENIX TECHNOLOGY., CO. FL 9, NO. 100-1, MIN-CHUAN RD. SHING TIEN CITY, TAIPEI, TAIWAN The following merchandise was submitted and identified by

More information

Microsoft Word - LD5515_5V1.5A-DB-01 Demo Board Manual

Microsoft Word - LD5515_5V1.5A-DB-01 Demo Board Manual Subject LD5515 Demo Board Model Name (5V/1.5A) Key Features Built-In Pump Express TM Operation Flyback topology with PSR Control Constant Voltage Constant Current High Efficiency with QR Operation (Meet

More information

HC20131_2010

HC20131_2010 Page: 1 of 8 Date: April 14, 2010 WINMATE COMMUNICATION INC. 9 F, NO. 111-6, SHING-DE RD., SAN-CHUNG CITY, TAIPEI, TAIWAN, R.O.C. The following merchandise was submitted and identified by the vendor as:

More information

Microsoft Word - c1467602

Microsoft Word - c1467602 ICS 33.100.20-1- 中 國 國 家 標 準 CNS 電 磁 相 容 測 試 與 量 測 技 術 第 2 部 : 靜 電 放 電 免 疫 力 測 試 總 號 類 號 14676-2 C6424-2 Electromagnetic compatibility (EMC) - Testing and measurement techniques - Part 2 : Electrostatic

More information

( ) ( ) ( ) 1. OEM/ODM ANSI Z89.1 EN GB ANSI S

( ) ( ) ( ) 1. OEM/ODM ANSI Z89.1 EN GB ANSI S (2005-03-23) (2005-03-23) (2005-04-01) 1. OEM/ODM ANSI Z89.1 EN 397-1995 GB 2812-89 ANSI S.3.19-1974 1 2. 2.1 ANSI Z89.1 (1) 1.524 19.36~19.86kg.m/s 5.52m/s (2) 3.54~3.64kg 48 0.8mm 76mm (3) 0~4450N(0~1000lb)

More information

untitled

untitled (100V 120V 220V 230V) i ii ! (Return Lead) iii iv 1....... 1 1-1.... 1 1-2.... 2 2..... 4 3..... 3-1.... 3-2.... 3-3....... 4..... 9 5......... 5-1.LCD..... 5-2.... 5-3.... 5-4.... 6..... 6-1.... 6-2....

More information

untitled

untitled CE according to EUROPEAN STANDARD EN 55022:2006/A1:2007 Class B, EN 61000-3-2:2006, EN 61000-3-3:1995/A1:2001/A2:2005 and EN 55024:1998/A1:2001/A2:2003 ( IEC 61000-4-2:1995/A2:2000, IEC 61000-4-3:2002,

More information

K301Q-D VRT中英文说明书141009

K301Q-D VRT中英文说明书141009 THE INSTALLING INSTRUCTION FOR CONCEALED TANK Important instuction:.. Please confirm the structure and shape before installing the toilet bowl. Meanwhile measure the exact size H between outfall and infall

More information

Chroma 61500/ bit / RMS RMS VA ()61500 DSP THD /61508/61507/61609/61608/ (61500 ) Chroma STEP PULSE : LISTLIST 100 AC DC

Chroma 61500/ bit / RMS RMS VA ()61500 DSP THD /61508/61507/61609/61608/ (61500 ) Chroma STEP PULSE : LISTLIST 100 AC DC MODEL 61509/61508/61507/ 61609/61608/61607 PROGRAMMABLE AC POWER SOURCE MODEL 61509/61508/61507/ 61609/61608/61607 61509/61609: 6kVA 61508/61608: 4.5kVA 61507/61607: 3kVA : 0-175V/0-350V/Auto : DC, 15Hz-2kHz

More information

BC04 Module_antenna__ doc

BC04 Module_antenna__ doc http://www.infobluetooth.com TEL:+86-23-68798999 Fax: +86-23-68889515 Page 1 of 10 http://www.infobluetooth.com TEL:+86-23-68798999 Fax: +86-23-68889515 Page 2 of 10 http://www.infobluetooth.com TEL:+86-23-68798999

More information

01CP-WX3030WNetc_CO_ENG.indd

01CP-WX3030WNetc_CO_ENG.indd Data Video Projector User s Manual (Concise) ModelS: 8928A/8930A/8931WA/ 8933W Information in this Guide may change due to product improvements. To obtain the latest manuals, literature, and software please

More information

8260

8260 8260 2004 9 Lenovo 15 32 1 60 40 60 2 ... 6... 6... 7... 9... 11... 14... 15... 15... 16... 17 PictBridge... 18... 19... 19 Lenovo... 21 Lenovo... 23... 24... 25 Lenovo... 28... 29 3 ... 30... 30... 31...

More information

untitled

untitled : EM-B141520 () #1 ( ) #2 ( ) #3 #4 ( ) #5 #6 金 ( ) #7 #8 ( ) ASUS, H81M-D R2.0 ASUS ( ) H81M-D R2.0 CNS 13438 (C6357) 類 95.06.01 (SL2-IN-E-0004) 2014. 08. 25 (/ 理 ) 數 1 of 41 : ( ): H81M-D R2.0 : ASUS

More information

RF & MICROWAVE COMPONENTS

RF & MICROWAVE COMPONENTS MICROOT MICROWAVE CO., LTD. RF & MICROWAVE COMPONENTS WWW.MIC-ROOT.COM Catalogue 1. ABOUT MICROOT...3 2. Broadband 90/180deg Hybrid and Coupler...4 3. Broadband Power Divider... 13 4. Filter... 20 5. RF

More information

untitled

untitled for 47 CFR Part 15 Subpart C Equipment : Neo 1973 Trade Name Model No. FCC ID Filing Type Applicant : FIC : GTA01BV4 : EUNGTA01BV4 : Certification : FIC (First International Computer, Inc.) No. 300, Yang

More information

QIANZHENYU 2

QIANZHENYU 2 2009-8-7 QIANZHENYU 1 . 1.1 2001 2001 12 3 2009-8-7 QIANZHENYU 2 9 19 132 19 2009-8-7 QIANZHENYU 3 1.2 GB/T4765-1995 2009-8-7 QIANZHENYU 4 1.3 2009-8-7 QIANZHENYU 5 . 2.1 Electromagnetic Environment 2.2

More information

Microsoft PowerPoint - ATF2015.ppt [相容模式]

Microsoft PowerPoint - ATF2015.ppt [相容模式] Improving the Video Totalized Method of Stopwatch Calibration Samuel C.K. Ko, Aaron Y.K. Yan and Henry C.K. Ma The Government of Hong Kong Special Administrative Region (SCL) 31 Oct 2015 1 Contents Introduction

More information

Induction Heating and Melting Capacitors

Induction Heating and Melting Capacitors General Information Induction Heating and Melting Capacitors pplication: The capacitors are applicable for indoor use and intended to be used for power factor correction in induction heating, melting,

More information

* 1 * *1 *2 2

* 1 * *1 *2 2 * 1 * 2 1 2 *1 *2 2 3 1 2 7 bo 8 9 6 5 4 3 bn bm bl bk 1 2 3 * 4 5 6 7 8 9 bk bl p bq bp bm * bn bo bp bq * br br 8 . bs br bq bp bo 1234567 bo bnbm bl 8 9 bk 1 2 3 4 5 6 7 8 9 bk b bl bm bn bo bp

More information

Lexmark Z600 Series Color Jetprinter

Lexmark Z600 Series Color Jetprinter Z600 Series Color Jetprinter Windows 2003 1 www.lexmark.com 2003 1 LEXMARK INTERNATIONAL, INC. LEXMARK INTERNATIONAL, INC. Lexmark International, Inc., Department F95/032-2, 740 West New Circle Road, Lexington,

More information

OVLFx3C7_Series_A3_bgry-KB.pub

OVLFx3C7_Series_A3_bgry-KB.pub (5 mm) x High brightness with well-defined spatial radiation patterns x U-resistant epoxy lens x Blue, green, red, yellow Product Photo Here Each device in the OLFx3C7 series is a high-intensity LED mounted

More information

GH1220 Hall Switch

GH1220 Hall Switch Unipolar Hall Switch - Medium Sensitivity Product Description The DH220 is a unipolar h all switch designed in CMOS technology. The IC internally includes a voltage regulator, Hall sensor with dynamic

More information

untitled

untitled : EM-B1020487 () #1 #2 ( ) #3 #4 ( ) #5 #6 金 ( ) #7 ASUS, H61M-C ASUS ( ) H61M-C CNS 13438 (C6357) 類 95.06.01 (SL2-IN-E-0004) (/ 理 ) 數 1 of 42 : ( ): H61M-C : ASUS 北 北 立 路 150 4 樓 北 林 里 53-11 : (02) 2609-9301~2,

More information

Chapter 24 DC Battery Sizing

Chapter 24  DC Battery Sizing 26 (Battery Sizing & Discharge Analysis) - 1. 2. 3. ETAP PowerStation IEEE 485 26-1 ETAP PowerStation 4.7 IEEE 485 ETAP PowerStation 26-2 ETAP PowerStation 4.7 26.1 (Study Toolbar) / (Run Battery Sizing

More information

Microsoft PowerPoint - ryz_030708_pwo.ppt

Microsoft PowerPoint - ryz_030708_pwo.ppt Long Term Recovery of Seven PWO Crystals Ren-yuan Zhu California Institute of Technology CMS ECAL Week, CERN Introduction 20 endcap and 5 barrel PWO crystals went through (1) thermal annealing at 200 o

More information

LSC操作说明

LSC操作说明 1 C H R I S T A L P H A 1-4 LSC 型 Part. No. 102041 A L P H A 2-4 LSC 型 Part. No. 10204 冷 冻 干 燥 机 操 作 说 明 新 研 制 的 LSC-8 控 制 器, 具 备 图 形 显 示 功 能, 能 以 数 据 表 形 式 显 示 参 数, 并 可 选 配 控 制 软 件 LSC-8 1/4 VGA 大 屏 幕

More information

Microsoft Word - PZ series.doc

Microsoft Word - PZ series.doc 叠 层 片 式 铁 氧 体 磁 珠 P 系 列 Multilayer Chip Ferrite Bead P Series Operating Temp. : -4 ~ +8 特 征 FEATUES 内 部 印 有 银 电 极 的 叠 层 结 构, 铁 氧 体 屏 蔽 无 串 扰 Internal silver printed layers and magnetic shielded structures

More information

AS4610 Series QSG-EN_SC_TC R02.book

AS4610 Series QSG-EN_SC_TC R02.book Quick Start Guide 4/48-Port GE Data Center Switch AS460-0T AS460-0P AS460-54T AS460-54P. Unpack the Switch and Check Contents AS460-0T AS460-0P Note: The switch can also be installed on a desktop or shelf

More information

E15-3D1 1. Specifications Compact 4-Way Cassette type Model name MMU- AP0071MH2UL AP0091MH2UL AP0121MH2UL AP0151MH2UL AP0181MH2UL Cooling Capacity kbt

E15-3D1 1. Specifications Compact 4-Way Cassette type Model name MMU- AP0071MH2UL AP0091MH2UL AP0121MH2UL AP0151MH2UL AP0181MH2UL Cooling Capacity kbt E15-3D1 Compact 4-Way Cassette type MMU-AP0071MH2UL MMU-AP0091MH2UL MMU-AP0121MH2UL MMU-AP0151MH2UL MMU-AP0181MH2UL Contents 1. Specifications 2. Dimensions 3. Center of gravity 4. Piping diagram 5. Wiring

More information

. Land Patterns for Reflow Soldering.Recommended Reflow Soldering Conditions (For Lead Free) TYPE PID0703 PID0704 PID1204 PID1205 PID1207 PID1209 L(mm

. Land Patterns for Reflow Soldering.Recommended Reflow Soldering Conditions (For Lead Free) TYPE PID0703 PID0704 PID1204 PID1205 PID1207 PID1209 L(mm .Features: 1.Magnetic Shielded surface mount inductor with high current rating. 2.Low resistance to keep power loss minimum..applications: Excellent for power line DC-DC conversion applications used in

More information

卡尔费休库仑滴定仪和水蒸发器测量卡氏炉标准物质

卡尔费休库仑滴定仪和水蒸发器测量卡氏炉标准物质 Certificate of Ana lysis Apura Certified Reference Material Producer: Accreditation: Description of CRM: Lot No.: Composition: Merck KGaA, Frankfurter Str. 250, 64293 Darmstadt, Germany. Merck KGaA, Darmstadt,

More information

1.ai

1.ai HDMI camera ARTRAY CO,. LTD Introduction Thank you for purchasing the ARTCAM HDMI camera series. This manual shows the direction how to use the viewer software. Please refer other instructions or contact

More information

TX-NR3030_BAS_Cs_ indd

TX-NR3030_BAS_Cs_ indd TX-NR3030 http://www.onkyo.com/manual/txnr3030/adv/cs.html Cs 1 2 3 Speaker Cable 2 HDMI OUT HDMI IN HDMI OUT HDMI OUT HDMI OUT HDMI OUT 1 DIGITAL OPTICAL OUT AUDIO OUT TV 3 1 5 4 6 1 2 3 3 2 2 4 3 2 5

More information

Preface This guide is intended to standardize the use of the WeChat brand and ensure the brand's integrity and consistency. The guide applies to all d

Preface This guide is intended to standardize the use of the WeChat brand and ensure the brand's integrity and consistency. The guide applies to all d WeChat Search Visual Identity Guidelines WEDESIGN 2018. 04 Preface This guide is intended to standardize the use of the WeChat brand and ensure the brand's integrity and consistency. The guide applies

More information

热设计网

热设计网 例 例 Agenda Popular Simulation software in PC industry * CFD software -- Flotherm * Advantage of Flotherm Flotherm apply to Cooler design * How to build up the model * Optimal parameter in cooler design

More information

Table of Contents Power Film Capacitors Power Film Capacitors Series Table Product Type Series Voltage Capacitance() Page DC-Link Power Film Capacitors Power Film Capacitors Power Film Capacitors Power

More information

DreamStation CPAP DreamStation CPAP Pro DreamStation Auto CPAP

DreamStation CPAP DreamStation CPAP Pro DreamStation Auto CPAP DreamStation CPAP DreamStation CPAP Pro DreamStation Auto CPAP ... 1... 1... 1... 2... 2... 3... 3 Philips Respironics...3... 4 /...5... 6...6... 7... 8... 8...9... 9...10 Bluetooth...14...15...15...15...16...20...22...23...24...24...24...24...25...26...27

More information

Microsoft Word - FR B_R02_15C_High Tech_DIAM210_Report.doc

Microsoft Word - FR B_R02_15C_High Tech_DIAM210_Report.doc According to 47 CFR Part 15 Subpart C Equipment Model No. FCC ID Filing Type Applicant : PDA Phone : DIAM210 : NM8DMM : Certification : High Tech Computer Corp. 23 Xinghua Rd., Taoyuan 330, Taiwan The

More information

Microsoft Word - Lenovo_L15M3PB2 (Winbook)_3S1P_UN38.3 Test Report_SLEU

Microsoft Word - Lenovo_L15M3PB2 (Winbook)_3S1P_UN38.3 Test Report_SLEU Lithium-ion Battery UN38.3 Test Report Recommendations on the TRANSPORT OF DANGEROUS GOODS (Manual of Tests and Criteria, Fifth revised edition, Amend.2) Customer: Lenovo Model: L15M3PB2 Rating: 11.25V,

More information

Microsoft PowerPoint - TTCN-Introduction-v5.ppt

Microsoft PowerPoint - TTCN-Introduction-v5.ppt Conformance Testing and TTCN 工研院無線通訊技術部林牧台 / Morton Lin 03-5912360 mtlin@itri.org.tw 1 Outline Introduction and Terminology Conformance Testing Process 3GPP conformance testing and test cases A real world

More information

全汉不间断电源 全汉集团始于 1993 Began in 1993 UPS

全汉不间断电源 全汉集团始于 1993 Began in 1993 UPS 全汉不间断电源 全汉集团始于 1993 Began in 1993 UPS 专业卓越共赢 Professional excellence and win-win 目录 about company 1 1-3k 2 6-10k 3 RM 1-3k 4 RM 6-10k 5 RT 1-3K 6 RT 6-10K 7 3/1 10-30K 8 3/3 10-30K 9 3/3 40-200K 10 Mplus

More information

HC80279_2007

HC80279_2007 Reliability Laboratory Page: 1 of 7 Date: August 31, 2007 TEMWELL CORPORATION 8F-1, NO. 51, SEC. 1, MIN SHENG E. RD., TAIPEI, TAIWAN The following merchandise was submitted and identified by the vendor

More information

HWG0009-N0 MSL-T0350IC214.0-75B 深圳万润科技股份有限公司 胡文干.doc

HWG0009-N0 MSL-T0350IC214.0-75B 深圳万润科技股份有限公司 胡文干.doc 客 户 承 认 书 SPECIFICATION FOR APPROVAL CUSTOMER./ 客 户 : CUSTOMER P.N./ 客 户 物 料 号 : MODEL OF CERTIFICATE/ 认 证 型 号 : EUC-075S035ST-0009 PRODUCT MODEL/ 产 品 型 号 : MSL-T0350IC214.0-75B PRODUCT NO./ 产 品 编 号 :

More information

ZLF0206-N0 MSL-T2800IC36.0-100B 木林森股份有限公司 朱龙福 UL.doc

ZLF0206-N0 MSL-T2800IC36.0-100B 木林森股份有限公司 朱龙福 UL.doc 客 户 承 认 书 SPECIFICATION FOR APPROVAL CUSTOMER./ 客 户 : CUSTOMER P.N./ 客 户 物 料 号 : MODEL OF CERTIFICATE/ 认 证 型 号 : EUC-100S280ST-0206 PRODUCT MODEL/ 产 品 型 号 : MSL-T2800IC36.0-100B PRODUCT NO./ 产 品 编 号 :

More information

iml88-0v C / 8W T Tube EVM - pplication Notes. IC Description The iml88 is a Three Terminal Current Controller (TTCC) for regulating the current flowi

iml88-0v C / 8W T Tube EVM - pplication Notes. IC Description The iml88 is a Three Terminal Current Controller (TTCC) for regulating the current flowi iml88-0v C / 8W T Tube EVM - pplication Notes iml88 0V C 8W T Tube EVM pplication Notes Table of Content. IC Description.... Features.... Package and Pin Diagrams.... pplication Circuit.... PCB Layout

More information

LH_Series_Rev2014.pdf

LH_Series_Rev2014.pdf REMINDERS Product information in this catalog is as of October 2013. All of the contents specified herein are subject to change without notice due to technical improvements, etc. Therefore, please check

More information

5991-1117CHCN.indd

5991-1117CHCN.indd 开 关 电 源 测 量 应 用 指 南 使 用 Agilent InfiniiVision 3000/4000 X 系 列 示 波 器 并 结 合 开 关 电 源 测 量 选 件 简 介 配 有 开 关 电 源 测 量 选 件 的 Agilent 3000 和 4000 X 系 列 示 波 器 能 够 提 供 一 个 快 速 且 方 便 的 方 法, 帮 助 您 分 析 开 关 电 源 的 可 靠

More information

iml v C / 0W EVM - pplication Notes. IC Description The iml8683 is a Three Terminal Current Controller (TTCC) for regulating the current flowin

iml v C / 0W EVM - pplication Notes. IC Description The iml8683 is a Three Terminal Current Controller (TTCC) for regulating the current flowin iml8683-220v C / 0W EVM - pplication Notes iml8683 220V C 0W EVM pplication Notes Table of Content. IC Description... 2 2. Features... 2 3. Package and Pin Diagrams... 2 4. pplication Circuit... 3 5. PCB

More information

Microsoft Word - MTK平台生产软件使用说明.doc

Microsoft Word - MTK平台生产软件使用说明.doc MTK 1. 1.1 SMT BSN 1.2 1 IMEI 2. 2 2.1 MTK Flash Flash NAND FlashMP3 1 SMT SOFT Flash 2 SOFT MKT USB-RS232 921600 8 2.2 COPY 2.3 USB PCUSB USB 8 USB USB USB-RS232 (USB ) RS232 PCRS232 8 4V2A 2.4 DA File

More information

untitled

untitled GSM CDMA 1 YD 1032-2000 / GSM 900MHz DCS 1800MHz MS EMC 2 GB 19484.1 2004 / CDMA 800MHz MS EMC /CDMA2000 MS EMC 3 GB/T 6113.1 1995 GB 9254-1998 EN 301 489 1 V1.3.1 (2000-12) Electromagnetic compatibility

More information

iml v C / 4W Down-Light EVM - pplication Notes. IC Description The iml8683 is a Three Terminal Current Controller (TTCC) for regulating the cur

iml v C / 4W Down-Light EVM - pplication Notes. IC Description The iml8683 is a Three Terminal Current Controller (TTCC) for regulating the cur iml8683-220v C / 4W Down-Light EVM - pplication Notes iml8683 220V C 4W Down Light EVM pplication Notes Table of Content. IC Description... 2 2. Features... 2 3. Package and Pin Diagrams... 2 4. pplication

More information

Pin Configurations Figure2. Pin Configuration of FS2012 (Top View) Table 1 Pin Description Pin Number Pin Name Description 1 GND 2 FB 3 SW Ground Pin.

Pin Configurations Figure2. Pin Configuration of FS2012 (Top View) Table 1 Pin Description Pin Number Pin Name Description 1 GND 2 FB 3 SW Ground Pin. Features Wide 3.6V to 32V Input Voltage Range Output Adjustable from 0.8V to 30V Maximum Duty Cycle 100% Minimum Drop Out 0.6V Fixed 300KHz Switching Frequency 12A Constant Output Current Capability Internal

More information

Specification For 46 Watts

Specification For 46 Watts SPECIFICATION FOR APPROVAL CUSTOMER : CUSTOMER P.N. : PRODUCT MODEL : JAMSP-ZA700IC72VO-050D PRODUCT NO. : MFT0057-NO SAMPLE DATE : 2013-06-01 CUSTOMER AUTHORIZED SIGNATURE Please return to us one copy

More information

Form: RWPRR401-B

Form: RWPRR401-B Form: RWPRR401-B C C S 通 函 Circular 中 国 船 级 社 (2011 年 ) 通 函 第 81 号 总 第 145 号 2011 年 10 月 17 日 ( 共 4+26 页 ) 发 : 总 部 有 关 处 室 上 海 规 范 所 各 审 图 中 心 各 分 社 本 社 验 船 师 有 关 船 厂 产 品 制 造 厂 设 计 院 及 航 运 公 司 实 施 有 关

More information

Rotary Switch Catalogue

Rotary Switch Catalogue Rotary Switches RS300/400/500 Series Outline Our RS series embody the manufacturing history of our company. All series are sturdy and solid with high dependability designed for control units of plants,

More information

Current Sensing Chip Resistor

Current Sensing Chip Resistor 承認書 APPROVAL SHEET 廠商 : 客戶 : 麗智電子 ( 昆山 ) 有限公司 核準審核制作核準審核簽收 公 司 章 公 司 章 Liz Electronics (Kunshan) Co., LTD No. 989, Hanpu Road Kunshan City Jiangsu Province China Tel:0086-0512-57780531 Fax:0086-0512-57789581

More information

bingdian001.com

bingdian001.com .,,.,!, ( ), : r=0, g=0, ( ). Ok,,,,,.,,. (stackup) stackup, 8 (4 power/ground 4,sggssggs, L1, L2 L8) L1,L4,L5,L8 , Oz Oz Oz( )=28.3 g( ), 1Oz, (DK) Cx Co = Cx/Co = - Prepreg/Core pp,,core pp,, pp.,, :,,

More information

QQGQ2.E Power Supplies, Information Technology Equipment Including Ele... 1/10

QQGQ2.E Power Supplies, Information Technology Equipment Including Ele... 1/10 QQGQ2.E232014 - Power Supplies, Information Technology Equipment Including Ele... 1/10 QQGQ2.E232014 Power Supplies, Information Technology Equipment Including Electrical Business Equipment - Component

More information

1-S40A...-1 DAT00452 V.005

1-S40A...-1 DAT00452 V.005 1. 1-S40A -1 Technical data: DATA SHEET Technical data Unit 1-S40A -1 OIML R60 D1 C3 Emax Max. capacity Kg 50,100,200,500 50,100,200,500 t 1, 2, 3, 5 1, 2, 3, 5 vmin % of Cn 0.0286 0.0120 Sensitivity mv/v

More information

IEC A( ) B C D II

IEC A( ) B C D II ICS 13.120 K 09 GB 4706.1 2005/IEC 60335-1:2004(Ed4.1) 1 Household and similar electrical appliances- Safety General requirements IEC60335-1 2004 Ed4.1,IDT 2005-08-26 2006-08-01 IEC 1 2 3 4 5 6 7 8 9 10

More information

ESD.xls

ESD.xls Transient Suppressor Reverse Reverse ESD Capacitance Stand-off Beakdown Package Contact/Air Channel Circuit Diagram Pin Configuration Remark CMTLCP020CR35BFE CMTLDF02CR35AFE CMTLDF02CR50BLE CSP020 (pf)

More information

pdf

pdf THE INSTLLING INSTRUCTION FOR CONCELED TNK Important instuction:.. Please confirm the structure and shape before installing the toilet bowl. Meanwhile measure the exact size H between outfall and infall

More information

Important Notice SUNPLUS TECHNOLOGY CO. reserves the right to change this documentation without prior notice. Information provided by SUNPLUS TECHNOLO

Important Notice SUNPLUS TECHNOLOGY CO. reserves the right to change this documentation without prior notice. Information provided by SUNPLUS TECHNOLO Car DVD New GUI IR Flow User Manual V0.1 Jan 25, 2008 19, Innovation First Road Science Park Hsin-Chu Taiwan 300 R.O.C. Tel: 886-3-578-6005 Fax: 886-3-578-4418 Web: www.sunplus.com Important Notice SUNPLUS

More information

* RRB *

* RRB * *9000000000RRB0010040* *9000000000RRB0020040* *9000000000RRB0030040* *9000000000RRB0040040* *9000000000RRC0010050* *9000000000RRC0020050* *9000000000RRC0030050* *9000000000RRC0040050* *9000000000RRC0050050*

More information

G2001-204510

G2001-204510 申 请 编 号 :A2013CCC0907-1594801 第 1 页 共 10 页 报 告 编 号 :C-001-13CQC0687-D-E 1. 受 试 设 备 (EUT) 的 设 置 和 工 作 状 态 : 1 试 验 电 压 :AC220V/50Hz 2 传 导 试 验 EUT 设 置 和 工 作 状 态 : 电 源 端 子 : 受 试 设 备 (EUT) 的 输 出 端 接 负 载 ( 存

More information

Microsoft Word - Lenovo_L14M4P23 (Y51)_4S1P_UN38.3 Test Report_SLEU

Microsoft Word - Lenovo_L14M4P23 (Y51)_4S1P_UN38.3 Test Report_SLEU Lithium-ion Battery UN38.3 Test Report Recommendations on the TRANSPORT OF DANGEROUS GOODS (Manual of Tests and Criteria, Fifth revised edition, Amend 1) Customer: Lenovo Model: L14M4P23 Rating: 14.8V,

More information

HP lc200w_UM_Chinese_T_

HP lc200w_UM_Chinese_T_ lc200w 微 型 生 活 記 錄 器 使 用 說 明 書 目 錄 FCC statement... 5 禁 止 同 置... 6 FCC specific absorption rate (SAR) statement... 6 WEEE 通 知... 6 CE regulatory notice... 6 射 頻 暴 露 信 息 (SAR)- CE... 6 NCC 警 語... 7 電 池

More information

PowerPoint Presentation

PowerPoint Presentation Current Status of the 10G-EPON Power Budget and Improvement David Li, Hisense-Ligent dli@ligentphotonics.com Ligent Supporters Bo Wang, China Telecom David Li, Ligent Photonics Frank Chang, Vitesse Corp.

More information

Microsoft Word - P SDV series.DOC

Microsoft Word - P SDV series.DOC 片式压敏电阻器 SDV 系列 Chip SDV Series Operating Temp. : -55 ~ +125 特征 SMD 结构适合高密度安装 优异的限压比, 响应时间短 (

More information

穨control.PDF

穨control.PDF TCP congestion control yhmiu Outline Congestion control algorithms Purpose of RFC2581 Purpose of RFC2582 TCP SS-DR 1998 TCP Extensions RFC1072 1988 SACK RFC2018 1996 FACK 1996 Rate-Halving 1997 OldTahoe

More information

68369 (ppp quickstart guide)

68369 (ppp quickstart guide) Printed in USA 04/02 P/N 68369 rev. B PresencePLUS Pro PC PresencePLUS Pro PresencePLUS Pro CD Pass/Fails page 2 1 1. C-PPCAM 2. PPC.. PPCAMPPCTL 3. DB9D.. STPX.. STP.. 01 Trigger Ready Power 02 03 TRIGGER

More information

ch_code_infoaccess

ch_code_infoaccess 地 產 代 理 監 管 局 公 開 資 料 守 則 2014 年 5 月 目 錄 引 言 第 1 部 段 數 適 用 範 圍 1.1-1.2 監 管 局 部 門 1.1 紀 律 研 訊 1.2 提 供 資 料 1.3-1.6 按 慣 例 公 布 或 供 查 閱 的 資 料 1.3-1.4 應 要 求 提 供 的 資 料 1.5 法 定 義 務 及 限 制 1.6 程 序 1.7-1.19 公 開 資

More information

< B9E2BBFAD7DBBACFCDBCB2E1B6A8B8E52DC7E5CEFAB0E6312E706466>

< B9E2BBFAD7DBBACFCDBCB2E1B6A8B8E52DC7E5CEFAB0E6312E706466> XYR XYR XYR Tel: 00 567068 www.zolix.com.cn 99 Tel: 00 567068 www.zolix.com.cn XYR500 XYR500 XYR000 XYR0000-CH XYmm.5 0 5 z 5 mm 5050 0000 0000 mm 00 00 0000 mm 6.5 76 98 8 Kg 6 8 5 XY/μm 0/5 0XYμm 0.5

More information

入學考試網上報名指南

入學考試網上報名指南 入 學 考 試 網 上 報 名 指 南 On-line Application Guide for Admission Examination 16/01/2015 University of Macau Table of Contents Table of Contents... 1 A. 新 申 請 網 上 登 記 帳 戶 /Register for New Account... 2 B. 填

More information

Gerotor Motors Series Dimensions A,B C T L L G1/2 M G1/ A 4 C H4 E

Gerotor Motors Series Dimensions A,B C T L L G1/2 M G1/ A 4 C H4 E Gerotor Motors Series Size CC-A Flange Options-B Shaft Options-C Ports Features 0 0 5 5 1 0 1 0 3 3 0 0 SAE A 2 Bolt - (2) 4 Bolt Magneto (4) 4 Bolt Square (H4) 1.0" Keyed (C) 25mm Keyed (A) 1.0' 6T Spline

More information

Microsoft Word - VA REV.A.doc

Microsoft Word - VA REV.A.doc Data Sheet Customer: Product : Multilayer Chip Varistor - VA Series Size: 0402/0405/0508/0603/0612/0805/1206/1210/1812 /2220 Issued Date: 22-Jan-11 Edition : REV.A VIKING TECH CORPORATION 光頡科技股份有限公司 No.70,

More information

Microsoft Word - SWRH-B series of Shielded SMD Power Inductor.doc

Microsoft Word - SWRH-B series of Shielded SMD Power Inductor.doc Wire Wound SMD Power Inductors SWRH-B Series Operating Temperature: -25 ~+105 (Including self-heating) FEATURES Various high power inductors are superior to be high saturation Suitable for surface mounting

More information

( )

( ) Secondary School Physical Fitness Award Scheme Student s Handbook Jointly Organized By Hong Kong Childhealth Foundation Education Department ( ) Secondary School Physical Fitness Award Scheme Student s

More information

用EMI接收机测量喀呖声

用EMI接收机测量喀呖声 Using EMI receiver to measure discontinuous disturbance (click) 是德科技 ( 中国 ) 有限公司以是为本以德致远专注测量 75 载 YANG Peiwen 杨培文 Keysight EMC Business Development Manager Agenda Definition and Standards Using EMI receiver

More information

Gerolor Motors Series Dimensions A,B C T L L G1/2 M8 G1/ A 4 C H4 E

Gerolor Motors Series Dimensions A,B C T L L G1/2 M8 G1/ A 4 C H4 E Gerolor Motors Series Size CC-A Flange Options-B Shaft Options-C Ports Features 0 0 12 12 1 1 0 0 2 2 31 31 0 0 SAE A 2 Bolt - (2) 4 Bolt Magneto (4) 4 Bolt Square (H4) 1.0" Keyed (C) 2mm Keyed (A) 1.0'

More information

JOURNAL OF EARTHQUAKE ENGINEERING AND ENGINEERING VIBRATION Vol. 31 No. 5 Oct /35 TU3521 P315.

JOURNAL OF EARTHQUAKE ENGINEERING AND ENGINEERING VIBRATION Vol. 31 No. 5 Oct /35 TU3521 P315. 31 5 2011 10 JOURNAL OF EARTHQUAKE ENGINEERING AND ENGINEERING VIBRATION Vol. 31 No. 5 Oct. 2011 1000-1301 2011 05-0075 - 09 510405 1 /35 TU3521 P315. 8 A Earthquake simulation shaking table test and analysis

More information

Microsoft Word - c1380300.doc

Microsoft Word - c1380300.doc ICS 33.100.10 中 國 國 家 標 準 CNS - 1- 工 業 科 學 醫 學 射 頻 設 備 之 電 磁 干 擾 特 性 的 限 制 值 與 量 測 法 總 號 類 號 13803 C6383 Limits and methods of measurement of electromagnetic interference characteristics of industrial,

More information

DR2010.doc

DR2010.doc DR/2010 HACH 11-8-96-2 HACH. DR/2010, / UL E79852 CSA C22.223 LR 58275 VDE GS 1015-92 FCC"A" 15 : AMADOR CORP, HACH. EN50 011/CISPR 11 "B" (EMI)/89/336/EEC/EMC: AMADOR CORP, HACH.. EN50 082-1( )/89/226/EEC

More information

Page of 1 Pages Luminous Intensity Distribution Curve

Page of 1 Pages Luminous Intensity Distribution Curve 86-760-88758975 Page 1 of 1 Pages Report No.: 1 Test Time: 018//1 1:48 Luminaire Property Luminaire Manufacturer: Luminaire Description: WANT-YS-80W Voltage: 0 V Current: 65 A Power: 77.4W Power Factor:

More information

同步伺朊电机CMP40 ~ 112、CMPZ71 ~ 100

同步伺朊电机CMP40 ~ 112、CMPZ71 ~ 100 驱动技术 \ 驱动自动化 \ 系统集成 \ 服务 *22491708_0316* 操作手册补充文件 安全评估编码器 AK0H(FS) AK1H(FS) 同步伺服电机CMP40 ~ 112 CMPZ71 ~ 100 安全功能 03/2016 版本 22491708/ZH-CN SEW-EURODRIVE Driving the world 目 录 目 录 1 概 述... 5 1.1 手 册 的 使

More information

TSI 8384/8385/8386 Manual

TSI 8384/8385/8386 Manual 8384/85/86 TSI/ VELOCITY FLOWRATE PRESSURE zero TEMP HUMIDITY SAMPLE options NEXT TEST clear STATISTICS review data SAMPLE INTERVAL HEAT FLOW THERMAL PITOT ACTUAL STANDARD ENTER ON/OFF 7 1 8 TEL:(02)26018201

More information

untitled

untitled : EM-B1021010 () #1 #2 ( ) #3 #4 ( ) #5 #6 金 ( ) #7 ASUS, H81-PLUS ASUS ( ) H81-PLUS CNS 13438 (C6357) 類 95.06.01 (SL2-IN-E-0004) ( 劉 李 / 理 ) 數 1 of 41 : ( ): H81-PLUS : ASUS 北 北 立 路 150 4 樓 北 林 里 53-11

More information

GB Sparkle

GB Sparkle GB 24613-2009 Chinese Mandatory Standard for Toy Coatings With growth of the toy industry and improvement of toys quality, the China National Paints and Pigments Standardization Technical Committee introduced

More information

ICS 29.220.01 K 81 GB/T 19826 2005 General specification and safety requirements for DC power supply equipment of power projects 2005-07-29 2006-07-01 ... III 1... 1 2... 1 3... 2 4... 3 5... 4 6... 12

More information

MODEL 62000H SERIES 5KW / 10KW / 15KW 0 ~ 375A 0 ~ 1000V/2000V( ) : 200/220Vac, 380/400Vac, 440/480Vac 3U/15KW / & 150KW / ( 10 ms ~ 99 hours)

MODEL 62000H SERIES 5KW / 10KW / 15KW 0 ~ 375A 0 ~ 1000V/2000V( ) : 200/220Vac, 380/400Vac, 440/480Vac 3U/15KW / & 150KW / ( 10 ms ~ 99 hours) MODEL 62000H SERIES 5KW / 10KW / 15KW 0 ~ 375A 0 ~ 1000V/2000V( ) : 200/220Vac, 380/400Vac, 440/480Vac 3U/15KW / &150KW / ( 10 ms ~ 99 hours) 10 100 / PROGRAMMABLE DC POWER SUPPLY MODEL 62000H SERIES USB

More information

(baking powder) 1 ( ) ( ) 1 10g g (two level design, D-optimal) 32 1/2 fraction Two Level Fractional Factorial Design D-Optimal D

(baking powder) 1 ( ) ( ) 1 10g g (two level design, D-optimal) 32 1/2 fraction Two Level Fractional Factorial Design D-Optimal D ( ) 4 1 1 1 145 1 110 1 (baking powder) 1 ( ) ( ) 1 10g 1 1 2.5g 1 1 1 1 60 10 (two level design, D-optimal) 32 1/2 fraction Two Level Fractional Factorial Design D-Optimal Design 1. 60 120 2. 3. 40 10

More information

MS24264 连接器

MS24264 连接器 DETAIL SPECIFICATION SHEET CONNECTORS, RECEPTACLE, ELECTRICAL, FLANGE MOUNTING, MINIATURE, CLASSES E, F, G AND R Inactive for new design for 14 November 1977.For new design, use MIL-DTL-83723, series III,

More information

Logitech Wireless Combo MK45 English

Logitech Wireless Combo MK45 English Logitech Wireless Combo MK45 Setup Guide Logitech Wireless Combo MK45 English................................................................................... 7..........................................

More information