EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 1 Of 11 LUMINAIRE PHOTOMETRIC TEST REPORT Test:U:12.4V I:.256A P:3.12W PF:.991 Lamp Flux:352.3x1 lm SERIAL No.:27 DATA OF LAMP PHOTOMETRIC DATA Eff: 116.28 lm/w MODEL ASD-LVP2SM-4N315HE Imax(cd) 15 S/MH(C/18) 1.29 NOMINAL POWER(W) 3 LOR(%) 1. S/MH(C9/27) 1.24 RATED VOLTAGE(V) 12 TOTAL FLUX(lm) 352.3 UP,DN(C-18) 3.,46.2 NOMINAL FLUX(lm) 352.3 CIE CLASS DIRECT UP,DN(C18-36) 3.3,47.5 LAMPS INSIDE 1 up(%) 6.4 CIBSE SHR NOM 1.25 TEST VOLTAGE(V) 12.4 down(%) 93.6 CIBSE SHR MAX 1.35 LUMINOUS INTENSITY DISTRIBUTION DIAGRAM C PLANE ISOLUX DIAGRAM (UNIT:lx) MH(m) 14-15 -/+18 15 18 22-12 12 26 3-9 9 34 3 6-6 9 6 12 UNIT:cd C/18,128.6deg -3 15 3 C9/27,11.9deg AVERAGE BEAM ANGLE(5%):119.7 DEG 38 42 46. 17. 34. 6.1 5.1 1..81 S(m) 4. 3. 2..51.4.3 C Range: - 36DEG C Interval: 45.DEG Test Date:215-9-26 Range: - 18DEG Interval: 1.DEG Test System:EVERFINE GO-2A_V1 SYSTEM V2..281 Humidity:65.% Test Distance:18.4m [K=1.] D:\ 卜礼佳 \ASD-LVP2SM-4N315HE.GOS
EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 2 Of 11 ZONAL FLUX DIAGRAM AND LUMINANCE LIMITATION CURVES ZONAL FLUX DIAGRAM: C C45 C9 C135 C18 C225 C27 C315 zone total %lum,lamp 1 985.9 989.7 983.8 978.5 991.5 983.4 985.3 994.6-1 95. 95. 2.76,2.76 2 939.4 942.4 926.7 92.2 949.3 929.6 93. 951.9 1-2 272.5 367.5 1.7,1.7 3 868.8 865.3 837. 832.4 88.7 846.3 842.1 879. 2-3 414.8 782.3 22.7,22.7 4 776.2 763.2 719.9 721. 789.2 738.2 726.7 78.4 3-4 55. 1287 37.4,37.4 5 667.2 641.3 58.8 592.4 68.6 612.4 589.2 661.7 4-5 534.1 1821 52.9,52.9 6 547.5 57.5 423.6 455.3 561.2 476.7 433.9 529.7 5-6 52. 2323 67.4,67.4 7 426.4 371. 254. 321.5 44. 341.8 266.1 393.5 6-7 417.8 2741 79.6,79.6 8 313.1 246.1 89.25 24. 325.1 221.2 1.9 266.8 7-8 31. 342 88.3,88.3 9 216.5 147.7.611 116. 225.6 128.3 3.943 164.2 8-9 183.8 3226 93.6,93.6 1 14.1 81.67.545 61.27 146.8 68.64 1.49 91.69 9-1 17.1 3333 96.7,96.7 11 84.23 41.2.5678 3.67 89.71 34.85.649 45.74 1-11 59.67 3393 98.5,98.5 12 46.39 17.95.8263 14.39 51.6 16.88.9182 2.26 11-12 3 3423 99.3,99.3 13 22.63 7.351 1.46 5.998 26.42 7.349 1.175 8.74 12-13 13.62 3437 99.7,99.7 14 9.23 2.987 1.21 2.497 11.8 3.335 1.494 3.911 13-14 5.449 3442 99.9,99.9 15 3.276 1.75 1.43 1.719 4.412 5 1.74 2.2 14-15 2.38 3444 1,1 16 1.732 1.682 1.58 1.696 4 1.79 1.766 1.751 15-16.8894 3445 1,1 17 1.78 1.773 1.644 1.787 1.798 1.728 1 1.742 16-17.4869 3446 1,1 18 1.774 4 1.793 1.837 1.837 4 1.836 1.815 17-18.1689 3446 1,1 DEG LUMINOUS INTENSITY:cd UNIT:lm LUMINANCE LIMITATION CURVES GLARE CLASS ILLUMINANCE (lx) 1.15 A 2 1 5 <=3 1.5 B 2 1 5 <=3 1.85 C 2 1 5 <=3 2.2 D 2 1 5 <=3 2.55 E 2 1 5 <=3 a b c d e f g h a b c d e f g h G(DEG) 85 75 65 55 45 8 1 2 3 4 5 6 8 1 2 3 4 1 C/18 C9/27 LUMINANCE (cd/(m2)) 8 6 4 3 a/h 2 LUMINANCE cd/(m2) G(DEG) C/18 C9/27 85 842 837 8 542 1422 75 3976 184 7 3486 254 65 322 2223 6 362 2343 55 2964 2431 5 292 25 45 2861 2553 C Range: - 36DEG C Interval: 45.DEG Test Date:215-9-26 Range: - 18DEG Interval: 1.DEG Test System:EVERFINE GO-2A_V1 SYSTEM V2..281 Humidity:65.% Test Distance:18.4m [K=1.] D:\ 卜礼佳 \ASD-LVP2SM-4N315HE.GOS
EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 3 Of 11 CU AND LUMINAIRE BUDGETARY ESTIMATE DIAGRAM Test:U:12.4V I:.256A P:3.12W PF:.991 Lamp Flux:352.3x1 lm SERIAL No.:27 cc 8% 7% 5% 3% 1% w 5% 3% 1% 5% 3% 1% 5% 3% 1% 5% 3% 1% 5% 3% 1% fc 2% 2% 2% 2% 2% RCR RCR:Room Cavity Ratio Coefficients of Utilization(CU). 1.18 1.18 1.18 1.14 1.14 1.14 1.8 1.8 1.8 1.2 1.2 1.2.96.96.96.94 1...95.9.97.92.88.91.88.84.86.83.81.82.79.77.75 2..86.79.72.84.77.71.79.73.68.75.7.66.71.67.63.61 3..75.66.59.73.65.58.69.62.57.65.6.55.62.57.53.5 4..66.57.5.64.56.49.61.54.48.58.52.46.55.5.45.43 5..59.5.43.57.49.42.55.47.41.52.45.4.49.44.39 6..53.44.52.43.49.42.36.47.4.35.45.39.34 7..48.39.33.47.38.45.43.36.31.41.35.3.28 8..44.35.29.43.34.29.41.33.28.39.28.31.27.25 9..4.26.39.31.26.38.3.25.36.29.25.35.29.24.22 1..29.23.36.28.23.35.28.23.33.27.22.26.22.2 LAMPS 5 LUMINAIRE BUDGETARY DIAGRAM 4 3 2 1 9 8 7 6 5 4 3 5 6 6 H=7 H=7 CONDITIONS 4 5 4 2 1 2 3 4 5 7 1 2 3 5 7 1k 2k 3k 4k 5k 7k AREA(m2) FLUX 5lm FACTOR.7 Hdown.m Hwork.m Ework(AVE) 1lx cc w fc 7 5 3 5 3 2 C Range: - 36DEG C Interval: 45.DEG Test Date:215-9-26 Range: - 18DEG Interval: 1.DEG Test System:EVERFINE GO-2A_V1 SYSTEM V2..281 Humidity:65.% Test Distance:18.4m [K=1.] D:\ 卜礼佳 \ASD-LVP2SM-4N315HE.GOS
EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 4 Of 11 WEC AND CCEC Test:U:12.4V I:.256A P:3.12W PF:.991 Lamp Flux:352.3x1 lm SERIAL No.:27 cc 8% 7% 5% 3% 1% w 5% 3% 1% 5% 3% 1% 5% 3% 1% 5% 3% 1% 5% 3% 1% fc 2% 2% 2% 2% 2% RCR RCR:Room Cavity Ratio Wall Exitance Coeffcients(WEC). 1..356.23.64.347.198.63.33.189.6.314.181.58.3.174.56 2..318.174.54.31.171.53.295.164.51.281.157.49.268.151.48 3..287.153.46.28.15.45.266.144.44.254.139.43.242.134.41 4..261.136.4.254.133.39.242.128.38.231.124.22.12.36 5..239.122.35.233.12.35.222.116.34.212.112.33.22.18 6..22.11.215.18.31.25.15.31.195.12.3.187.98.29 7..23.11.29.199.99.28.19.96.28.181.93.27.174.9.26 8..189.92.26.185.91.26.177.88.25.169.86.25.162.83.24 9..177.86.24.173.84.24.165.82.23.159.79.23.152.77.22 1..166.79.22.162.78.22.155.76.21.149.74.21.143.72.21 cc w fc RCR. 1. 2. 3. 4. 5. 6. 7. 8. 9. 1. 8% 7% 5% 3% 1% 5% 3% 1% 5% 3% 1% 5% 3% 1% 5% 3% 1% 5% 3% 1% 2% 2% 2% 2% 2% RCR:Room Cavity Ratio Ceiling Cavity Exitance Coefficients(CCEC).239.233.225.217.21.22.194.187.181.175.169.239.25.181.164.151.141.133.126.12.115.111.239.18.144.121.16.96.88.83.79.75.73.24.199.193.186.18.173.167.161.156.15.145.24.176.156.141.131.122.115.19.14.1.96.24.155.125.15.92.83.77.72.69.66.63.139.136.132.128.124.119.115.111.18.14.11.139.121.18.98.91.85.8.77.73.7.68.139.8.17.78.87.76.74.74.65.72.59.69.54.67.51.65.49.63.47.61.45.59.8.8.7.62.63.51.57.44.53.38.5.35.47.45.3.43.29.42.28.4.27.26.26.25.23.24.2.24.19.23.17.22.16.22.15.21.15.2.14.2.14.19.13.26.2.17.14.13.12.11.1.1.9.9 C Range: - 36DEG C Interval: 45.DEG Test Date:215-9-26 Range: - 18DEG Interval: 1.DEG Test System:EVERFINE GO-2A_V1 SYSTEM V2..281 Humidity:65.% Test Distance:18.4m [K=1.] D:\ 卜礼佳 \ASD-LVP2SM-4N315HE.GOS
EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 5 Of 11 Uncorrected UGR Table Test:U:12.4V I:.256A P:3.12W PF:.991 Lamp Flux:352.3x1 lm SERIAL No.:27 ceiling/cavity.7.7.5.5.3.7.7.5.5.3 walls.5.3.5.3.3.5.3.5.3.3 working plane.2.2.2.2.2.2.2.2.2.2 Room dimensions Viewed crosswise Viewed endwise x = 2H y = 2H 3H 4H 6H 8H 12H 16.4 18.6 19.7 2.9 21.6 22.4 17.9 19.9 21. 22.2 22.8 23.5 16.8 19. 2.1 21.3 22. 22.8 18.2 2.3 21.4 22.6 23.2 23.9 18.6 2.7 21.8 23. 23.6 24.4 15.5 17. 17.6 17.9 18. 18. 17. 18.4 18.9 19.1 19.2 19.2 15.9 17.4 18. 18.3 18.4 18.4 17.3 18.7 19.2 19.5 19.6 19.6 17.7 19.1 19.6 2. 2. 2. 4H 2H 3H 4H 6H 8H 12H 17. 18.3 17.4 18.7 19.1 16.4 17.7 16.8 18. 18.4 19.4 2.6 19.8 21. 21.4 18.1 19.3 18.5 19.7 2.1 2.7 21.8 21.2 22.2 22.7 18.8 19.9 19.3 2.3 2.8 22.1 23.1 22.6 23.5 24. 19.4 2.3 19.9 2.8 21.3 22.9 23.8 23.4 24.3 24.8 19.5 2.4 2. 2.9 21.4 23.8 24.6 24.3 25.1 25.6 19.6 2.4 2.1 2.9 21.5 8H 4H 6H 8H 12H 21. 21.9 21.6 22.4 22.9 19.5 2.4 2. 2.9 21.4 22.7 23.5 23.3 24. 24.5 2.3 21.1 2.9 21.6 22.2 23.7 24.3 24.2 24.9 25.5 2.7 21.3 21.2 21.9 22.5 24.8 25.4 25.4 25.9 26.6 2.9 21.5 21.5 22. 22.7 12H 4H 6H 8H 21.1 22.8 23.9 21.9 23.5 24.5 21.6 23.4 24.5 22.4 24. 25. 22.9 24.6 25.6 19.7 2.7 21.1 2.5 21.3 21.7 2.2 21.2 21.7 21. 21.9 22.3 21.5 22.5 22.9 Variations with the observer position at spacings: S = 1.H +.1 / -.1 +.1 / -.2 1.5H +.2 / -.3 +.2 / -.3 2.H +.2 / -.3 +.2 / -.4 CIE Pub.117 Corrected 3446 lm Total Lamp Luminous Flux.(8log(F/F) = 4.3) C Range: - 36DEG C Interval: 45.DEG Test Date:215-9-26 Range: - 18DEG Interval: 1.DEG Test System:EVERFINE GO-2A_V1 SYSTEM V2..281 Humidity:65.% Test Distance:18.4m [K=1.] D:\ 卜礼佳 \ASD-LVP2SM-4N315HE.GOS
EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 6 Of 11 UTILIZATION FACTORS TABLE Test:U:12.4V I:.256A P:3.12W PF:.991 Lamp Flux:352.3x1 lm SERIAL No.:27 REFLECTANCE Ceiling.8.8.8.7.7.7.5.5.5 Walls.7.5.3.7.5.3.7.5.3 Working plane.2.2.2.2.2.2.2.2.2 ROOM INDEX UTILIZATION FACTORS(PERCENT) k(ri) x RCR = 5 k =.6 53 41 34 52 41 34 51 4 34 27.8 63 5 43 62 5 42 59 49 42 35 1. 71 59 51 69 58 5 67 59 5 42 1.25 78 66 58 76 65 58 73 63 57 48 1.5 83 72 64 81 71 63 77 68 62 53 2. 9 8 72 88 78 71 83 76 7 6 2.5 94 85 78 92 83 77 87 8 74 64 3. 98 89 83 95 87 81 9 84 79 68 4. 12 95 89 99 93 88 94 89 84 73 5. 15 99 94 12 96 92 96 92 88 77 ROOM INDEX UF(total) Direct According to DIN EN 1332-2 24 Suspended SHRNOM = 1.25 C Range: - 36DEG C Interval: 45.DEG Test Date:215-9-26 Range: - 18DEG Interval: 1.DEG Test System:EVERFINE GO-2A_V1 SYSTEM V2..281 Humidity:65.% Test Distance:18.4m [K=1.] D:\ 卜礼佳 \ASD-LVP2SM-4N315HE.GOS
EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 7 Of 11 ISOCANDELA DIAGRAM Test:U:12.4V I:.256A P:3.12W PF:.991 Lamp Flux:352.3x1 lm SERIAL No.:27 9 8 7 6 5 4 1% 11.1 2% 22.1 3% 33.2 4% 44.2 5% 55.3 6% 66.3 7% 77.4 8% 88.5 9% 99.5 3 2 VERTICAL(DEG) 1-1 -2-3 -4-5 -6-7 -8-9 -9-8 -7-6 -5-4 -3-2 -1 1 2 HORIZONTAL(DEG) 3 4 5 6 7 8 9 Imax:111(H-1.,V.) (At:C=315.,Gamma=2.) UNIT: cd C Range: - 36DEG C Interval: 45.DEG Test Date:215-9-26 Range: - 18DEG Interval: 1.DEG Test System:EVERFINE GO-2A_V1 SYSTEM V2..281 Humidity:65.% Test Distance:18.4m [K=1.] D:\ 卜礼佳 \ASD-LVP2SM-4N315HE.GOS
EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 8 Of 11 AAI Figure Test:U:12.4V I:.256A P:3.12W PF:.991 Lamp Flux:352.3x1 lm SERIAL No.:27 Flux out:213 lm 3.281ft 1m 28.66,93.88fc 38.5,11lx 9.41ft 286.55cm 6.562ft 2m 7.165,23.47fc 77.12,252.6lx 18.8ft 573.1cm 9.843ft 3m 3.184,1.43fc 34.28,112.3lx 28.2ft 859.66cm 13.12ft 4m 1.791,5.867fc 19.28,63.16lx 37.61ft 1146.21cm 16.4ft 5m 1.146,3.755fc 12.34,4.42lx 47.1ft 1432.76cm Height Eavg,Emax Angle:11.17deg Diameter Note:The Curves indicate the illuminated area and the average illumination when the luminaire is at different distance. C Range: - 36DEG C Interval: 45.DEG Test Date:215-9-26 Range: - 18DEG Interval: 1.DEG Test System:EVERFINE GO-2A_V1 SYSTEM V2..281 Humidity:65.% Test Distance:18.4m [K=1.] D:\ 卜礼佳 \ASD-LVP2SM-4N315HE.GOS
EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 9 Of 11 ISOLUX DIAGRAM Test:U:12.4V I:.256A P:3.12W PF:.991 Lamp Flux:352.3x1 lm SERIAL No.:27 15.' 52.5'.' 52.5' 15.' 131.2' 4.m 15.' 32.m 78.7' 24.m 3%.331lx.2816fc 5%.552lx.4694fc 1% 1.1lx.9388fc 3% 3.31lx.2816fc 5% 5.52lx.4694fc 52.5' 16.m 26.2' 8.m.'.m 26.2' 8.m 52.5' 16.m 78.7' 24.m 15.' 32.m 131.2' 4.m 32.m 16.m.m 16.m 32.m MOUNTING HEIGHT: 33'(1.m) C Range: - 36DEG C Interval: 45.DEG Test Date:215-9-26 Range: - 18DEG Interval: 1.DEG Test System:EVERFINE GO-2A_V1 SYSTEM V2..281 Humidity:65.% Test Distance:18.4m [K=1.] D:\ 卜礼佳 \ASD-LVP2SM-4N315HE.GOS
EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 1 Of 11 Planar Illuminance Curve 13.5 E(lx) 15 Planar Illuminance Curve MH = 1 m C/18 C9/27 12 1.5 9 7.5 6 4.5 3 1.5-25 -2-15 -1-5 5 1 15 2 25 Distance(m) C Range: - 36DEG C Interval: 45.DEG Test Date:215-9-26 Range: - 18DEG Interval: 1.DEG Test System:EVERFINE GO-2A_V1 SYSTEM V2..281 Humidity:65.% Test Distance:18.4m [K=1.] D:\ 卜礼佳 \ASD-LVP2SM-4N315HE.GOS
EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 11 Of 11 LUMINOUS DISTRIBUTION INTENSITY DATA Test:U:12.4V I:.256A P:3.12W PF:.991 Lamp Flux:352.3x1 lm SERIAL No.:27 Table--1 C(DEG) (DEG) 14 5 999 1 986 15 966 2 939 25 97 3 869 35 825 4 776 45 723 5 667 55 68 6 548 65 487 7 426 75 368 8 313 85 262 9 217 95 176 1 14 15 11 11 84.2 115 63.2 12 46.4 125 33.1 13 22.6 135 14.8 14 9.23 145 5.6 15 3.28 155 2.9 16 1.73 165 1.7 17 1.71 175 1.71 18 1.77 45 14 11 99 97 942 97 865 817 763 74 641 575 58 439 371 36 246 193 148 111 81.7 56.6 41. 28.3 17.9 11.5 7.35 4.66 2.99 2.12 1.71 1.67 1.68 1.72 1.77 9 14 998 984 959 927 886 837 781 72 653 581 54 424 34 254 169 89.2 26.4.6.57.54.55.57.75.83.9 1.5 1.14 1.21 1.3 1.43 1.47 1.51 1.56 1.64 1.73 1.79 135 14 996 978 953 92 879 832 779 721 658 592 524 455 387 321 26 24 156 116 84.9 61.3 43.6 3.7 21.2 14.4 9.5 6. 3.88 2.5 1.81 1.72 1.64 1.7 1.75 1.79 1.83 1.84 18 14 11 992 974 949 918 881 837 789 737 681 622 561 5 44 381 325 273 226 183 147 116 89.7 68.3 51.1 37.3 26.4 17.5 11.1 7.31 4.41 2.55 1.76 1.8 1.84 225 14 998 983 961 93 891 846 795 738 677 612 545 477 48 342 279 221 171 128 94.4 68.6 49. 34.8 24.5 16.9 11.4 7.35 4.94 3.34 2.31 1.7 1.71 1.72 1.73 1.74 27 14 999 985 962 93 89 842 787 727 661 589 514 434 351 266 181 11 34.8 3.94 2.5 1.5.53.64.77.92 1.5 1.17 1.3 1.49 1.63 1.7 1.74 1.77 1.79 1.84 1.84 315 14 14 995 978 952 919 879 833 78 723 662 597 53 461 394 328 267 212 164 123 91.7 66.5 45.7 33.1 2.3 13. 8.74 5.75 3.91 2.76 2.2 1.9 1.75 1.74 1.74 1.75 UNIT: cd C Range: - 36DEG C Interval: 45.DEG Test Date:215-9-26 Range: - 18DEG Interval: 1.DEG Test System:EVERFINE GO-2A_V1 SYSTEM V2..281 Humidity:65.% Test Distance:18.4m [K=1.] D:\ 卜礼佳 \ASD-LVP2SM-4N315HE.GOS